Cangzhou Puhui Electromechanical Equipment Co., Ltd
Home>Products>DF41-10 backflow preventer
DF41-10 backflow preventer
Reverse flow preventer, Puhui brand DF41-10 reverse flow preventer, reverse flow preventer manufacturer Puhui phone
Product details

Backflow preventer Puhui brand

DF41-10Backflow preventerThe manufacturer of backflow preventer, Puhui Telephone. Backflow preventer is a hydraulic control combination device that strictly limits the unidirectional flow of water in pipelines. All models of backflow preventers are available, including backflow preventers. DF41-10 backflow preventer is a hydraulic control combination device that strictly limits the unidirectional flow of water in pipelines. Its function is to prevent the backflow of medium in pipelines under any working conditions, in order to avoid backflow pollution.

Main parameters of DF41-10 backflow preventer

Nominal pressure: 1.0MPa-1.6MPa-2.5MPa;

Specification caliber: 50 to 600mm;

Medium temperature: 0 to 80 degrees;

Applicable media: water, reclaimed water, sewage.

Connection form: flange;

Shell material: cast iron, brass;

Flange standard: GB/T17241.6 GB/T9113;

Test standard: GB/T13927,Ap1598。

Size and weight of backflow preventer:

Specifications 32 40 50 65 80 100 125 150 200 250 300 350 400 450
Weight kg 10.5 11 11
14 15 25 31 38 58 100 120
248 260
length 290 290 290 345 365 495 535 535 565 610 630 630 880 880
length
321 321 326 373 480 475 553 582 698 740 740

Model of backflow preventer

What are the models and specifications of backflow preventers? Specification caliber: Supply caliber: DN40-DN400; Specifically, there are DN40 DN50mm、DN65mm、DN80mm、DN100mm、DN125mm、DN150mm、DN200mm、DN250mm、DN300mm、DN350mm、DN400mm。

Pressure rating models: 1.0MPa, 1.6MPa, 2.5MPa.

Working principle of backflow preventer

  倒流防止器

Working principle of backflow preventerWhen the medium flows through the inlet check valve, the pressure is reduced due to mechanical resistance and the loss of the overflow head, making the pressure higher than the pressure in the drain valve chamber. The pressure in the upper part of the drain valve diaphragm is the pressure, and the pressure in the upper part of the diaphragm is greater than the resistance in the drain valve chamber and spring. The drain valve remains closed and the medium flows normally. When the pressure difference between the pressure and the pressure in the drain valve chamber is less than 0.02 Mpa, the medium is in a critical state of backflow. At this time, the pressure in the upper part of the drain valve diaphragm is less than the pressure in the drain valve chamber and spring, and the drain valve automatically opens to discharge the backflow medium out of the pipe. At the same time, a large amount of air enters the valve chamber, forming an air partition, and the medium flows backwards. When the pressure.

When the water pressure in the pipe network after the valve rises and exceeds the water pressure at the upstream end of the valve, if the one-way check valve is sealed properly and the water will not flow back, the drain valve will close and not release water. When the one-way check valve fails to seal and leaks, the drain valve will open to drain and release pressure.

倒流防止器结构图片

Installation position of DF41-10 backflow preventer

1. The municipal pipeline network connects the user's water intake pipe to the pipeline between the water meter and the valve.
2. On the inlet pipe or fire outlet pipe of the fire pump adapter.
3. There are chemicals injected into the water supply pipes in the water supply system.
4. On the cold water inlet pipe of the heater, and on the water supply pipeline that may cause backflow.

DF41-10 Backflow Preventer Installation Instructions

1. Before installation, clean all pipelines.
2. The backflow preventer should be installed horizontally in the direction of the valve body arrow, and the installation position should be convenient for height and maintenance.
3. Both ends of the backflow preventer should be equipped with maintenance gate valves, a filter should be installed in front, and one end should be equipped with a flexible joint.
4. The distance between the drainage outlet of the drain valve and the ground should not be less than 300mm, and a drainage ditch should be left below the drain valve.
5. After installation, when starting up for the first time, the outlet gate valve should be closed and slowly opened to allow the medium to slowly fill and prevent backflow
Open each test ball valve to remove valve air, wait for the valve chamber to be filled with water, slowly open the gate valve to allow water to fill the pipeline.
6. When the medium pressure changes, a small amount of leakage from the drain valve is a normal phenomenon.

Picture of backflow preventer

DF41-10倒流防止器毛坯 DF41-10倒流防止器半成品

Image description of backflow preventer: The left image shows the blank of the backflow preventer. Each blank needs to be strictly polished and polished. The image on the right shows the semi-finished product of the backflow preventer. A semi-finished product that has been sprayed and processed needs to undergo another pressure test before installing the copper parts and packaging them for shipment.

Price of backflow preventer

The price of backflow preventers varies every month, and the main factor determining the price of backflow preventers is the specifications and caliber, followed by the pressure rating that affects the price of backflow preventers. Our product is suitable for pipelines with clear water as the medium. The shell of the backflow preventer is made of cast iron material. If full copper manufacturing is required, it can be customized for production. We have advantages in price, quality, and after-sales service. 【 Puhui 】 DF41-10 backflow preventer, free installation plan provided. Limited edition promotion: 0317-8294124.

Backflow preventer related articles on this website:

Backflow preventer delivered with goods. Backflow preventer user manual

The reverse flow preventer is delivered with the goods. The reverse flow preventer user manual includes: 1. Why should the reverse flow preventer be used? 2. Typical installation scenarios for backflow preventers; 3. Installation and commissioning of backflow preventer. Why should a backflow preventer be used?

Cast iron backflow preventer DN32 flange type

The new DN32 flange type cast iron backflow preventer comes with free shipping. The DN32 flange type cast iron backflow preventer officially started on March 30, 2016 and is now available for sale and supply! The cast iron backflow preventer DN32 adopts a simple flange type connection method, which is easily connected to the pipeline

Category: Company Click: 200 Date: 2016-03-30

Where is the red backflow preventer in appearance

Where is the red appearance backflow preventer? On January 13, 2016, a user from Guangxi requested to purchase a backflow preventer with a red appearance. Where can I find one? Purchase a red appearance backflow preventer. Which company can immediately purchase a red appearance backflow preventer in stock

Category: Procurement Help Click: 73 Date: 2016-01-13

Ductile iron backflow preventer for fire protection

The limited edition fire-fighting red ductile iron backflow preventer is specially customized for production. What is the difference between a fire backflow preventer and a regular backflow preventer? Is there a difference in material? Different structures? To meet the needs of customers, we produce fire protection red backflow prevention

Category: Industry Click: 65 Date: 2016-01-06

Backflow preventer DN100 copper pressure 1

The reverse flow preventer DN100 produced in the Puhui Valve Workshop has a copper pressure of 1.6MPa and is made of brass material. Fill in the market situation where the material specification and diameter of the brass shell of the backflow preventer are limited to small diameters. The diameter range of the brass material supply for the backflow preventer is DN10

Category: Company Click: 198 Date: April 22, 2015


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!