VIP member
DG250- Compact Anaerobic Workstation
Principle: Cold catalysis principle, in a closed system, the oxygen and hydrogen inside the catalytic chamber react to generate water, and the oxygen
Product details
- Product description: Principle: Cold catalysis principle, in a closed system, oxygen and hydrogen in the catalytic chamber react to generate water through a catalyst, and oxygen is consumed to form an anaerobic environment. Combined with a gas supply system, constant temperature and humidity system, it provides a suitable environment for anaerobic microbial cultivation. host
- Condensation temperature:
- Vacuum degree:
- Freeze dried area:
- Product model:
- Instrument type:
- Instrument material:
- Instrument structure:
- Heating power:
- Sample size:
- Test tube size:
- Heating method:
- Electrical resistivity:
- Pure water quality:
- Product type:
- Category: Microbiology
Principle:
The principle of cold catalysis involves the reaction of oxygen and hydrogen in a closed system through a catalyst to generate water, which is then consumed to create an anaerobic environment. This, combined with a gas supply system, constant temperature and humidity system, provides a suitable environment for the cultivation of anaerobic microorganisms.
Main application areas:
Government testing agencies (Food and Drug Administration, CIQ, CDC, quality inspection, environmental monitoring), pharmaceutical companies, food industry (breweries, canning factories, dairy industry), medical, agricultural, petrochemical and energy departments, universities and research institutions, and water treatment plants.
Technical parameters:
·10mm polyacrylic acid (acrylic) material ensures good transparency, insulation, and corrosion resistance, excellent annealing process, and a structure that does not deform for ten years;
·The bare handed operating system can accommodate up to 240 90mm culture dishes in the chamber, while ensuring sufficient operating space. It can be fully used as a culture chamber to accommodate up to 400 90mm culture dishes; Can hold up to 30 500mL triangular bottles or 50 250mL triangular bottles; Can hold 70 250ml reagent bottles or 50 500mL reagent bottles; More than 50 homogeneous bags can be placed.
·The unique multifunctional porthole transfer system is divided into an outer door and an inner door, which facilitates internal operation and sample transfer by the operator, saves gas consumption, and can transfer 20 petri dishes simultaneously. The two operation ports are equipped with gas switches, and a single operation port can be operated;
·Standard external vacuum pump for vacuuming and inflating portholes; Double button foot switch, controls the vacuum and inflation process. The two porthole transfer systems are each equipped with an intake lock switch, which can be operated by a single porthole.
·Temperature control: Room temperature+1-52 ℃, PT100 temperature sensor, temperature stability ± 0.1 ℃, temperature uniformity ± 0.6 ℃
·Humidity control: Built in digital display humidity controller, built-in humidity sensor, can set humidity and display current humidity value, dual fan automatic cooling electronic dehumidification device, no need for desiccant, internal condensed water is discharged to the outside of the chamber by peristaltic pump, evaporated on evaporation paper, no additional maintenance required.
·No need to open the operation port, just press the commission button for initialization. Long press the buzzer twice for 75 minutes for initialization (large ventilation), and short press the buzzer once for 20 minutes for initialization (small ventilation).
·The catalyst ensures an anaerobic state and can normally maintain an internal oxygen concentration of<5ppm. No high temperature activation is required before each use, and it can be used continuously for more than two years
·Detoxification agents are used to remove anaerobic growth inhibitory factors such as hydrogen sulfide and volatile fatty acids, extending the service life of catalysts
·Optional drawer style single dish transfer system, convenient for quick transfer of small amounts of samples
·The overall detachable design of the lift off cover does not require tools and can be manually disassembled, making it easy to clean and transfer large amounts of samples or larger instruments
·Light source: Standard LED light, optional top fluorescent light component;
·The internal positive pressure is controlled at 1cm water column, and the one-way pressure relief valve ensures positive internal pressure to prevent oxygen from entering the chamber from outside
·The overall transparent design at the top provides excellent visibility for work and cultivation, and the internal spotlight makes it easy to observe extremely small bacterial colonies
·Four transport holes that integrate instruments for easy handling and movement
·Optional internal power socket facilitates the use of small experimental instruments in the incubator
·Optional anaerobic indicator pump with magnetic switch, indicating oxygen concentration as low as 700ppm (blue to colorless), convenient for observing whether the inside of the chamber has reached anaerobic state
·Aseptic control inside the box: formaldehyde fumigation or sodium hypochlorite wiping can be used
·Gas supply: dual cylinder gas supply, nitrogen cylinder and anaerobic mixture gas, anaerobic mixture gas composition: 10% H2, 10%CO2, 80%N2

The principle of cold catalysis involves the reaction of oxygen and hydrogen in a closed system through a catalyst to generate water, which is then consumed to create an anaerobic environment. This, combined with a gas supply system, constant temperature and humidity system, provides a suitable environment for the cultivation of anaerobic microorganisms.
Main application areas:
Government testing agencies (Food and Drug Administration, CIQ, CDC, quality inspection, environmental monitoring), pharmaceutical companies, food industry (breweries, canning factories, dairy industry), medical, agricultural, petrochemical and energy departments, universities and research institutions, and water treatment plants.
Technical parameters:
·10mm polyacrylic acid (acrylic) material ensures good transparency, insulation, and corrosion resistance, excellent annealing process, and a structure that does not deform for ten years;
·The bare handed operating system can accommodate up to 240 90mm culture dishes in the chamber, while ensuring sufficient operating space. It can be fully used as a culture chamber to accommodate up to 400 90mm culture dishes; Can hold up to 30 500mL triangular bottles or 50 250mL triangular bottles; Can hold 70 250ml reagent bottles or 50 500mL reagent bottles; More than 50 homogeneous bags can be placed.
·The unique multifunctional porthole transfer system is divided into an outer door and an inner door, which facilitates internal operation and sample transfer by the operator, saves gas consumption, and can transfer 20 petri dishes simultaneously. The two operation ports are equipped with gas switches, and a single operation port can be operated;
·Standard external vacuum pump for vacuuming and inflating portholes; Double button foot switch, controls the vacuum and inflation process. The two porthole transfer systems are each equipped with an intake lock switch, which can be operated by a single porthole.
·Temperature control: Room temperature+1-52 ℃, PT100 temperature sensor, temperature stability ± 0.1 ℃, temperature uniformity ± 0.6 ℃
·Humidity control: Built in digital display humidity controller, built-in humidity sensor, can set humidity and display current humidity value, dual fan automatic cooling electronic dehumidification device, no need for desiccant, internal condensed water is discharged to the outside of the chamber by peristaltic pump, evaporated on evaporation paper, no additional maintenance required.
·No need to open the operation port, just press the commission button for initialization. Long press the buzzer twice for 75 minutes for initialization (large ventilation), and short press the buzzer once for 20 minutes for initialization (small ventilation).
·The catalyst ensures an anaerobic state and can normally maintain an internal oxygen concentration of<5ppm. No high temperature activation is required before each use, and it can be used continuously for more than two years
·Detoxification agents are used to remove anaerobic growth inhibitory factors such as hydrogen sulfide and volatile fatty acids, extending the service life of catalysts
·Optional drawer style single dish transfer system, convenient for quick transfer of small amounts of samples
·The overall detachable design of the lift off cover does not require tools and can be manually disassembled, making it easy to clean and transfer large amounts of samples or larger instruments
·Light source: Standard LED light, optional top fluorescent light component;
·The internal positive pressure is controlled at 1cm water column, and the one-way pressure relief valve ensures positive internal pressure to prevent oxygen from entering the chamber from outside
·The overall transparent design at the top provides excellent visibility for work and cultivation, and the internal spotlight makes it easy to observe extremely small bacterial colonies
·Four transport holes that integrate instruments for easy handling and movement
·Optional internal power socket facilitates the use of small experimental instruments in the incubator
·Optional anaerobic indicator pump with magnetic switch, indicating oxygen concentration as low as 700ppm (blue to colorless), convenient for observing whether the inside of the chamber has reached anaerobic state
·Aseptic control inside the box: formaldehyde fumigation or sodium hypochlorite wiping can be used
·Gas supply: dual cylinder gas supply, nitrogen cylinder and anaerobic mixture gas, anaerobic mixture gas composition: 10% H2, 10%CO2, 80%N2

Online inquiry