DK-3001ATechnical parameters of the semi-automatic headspace sampler:
Headspace bottle specification: 20ml (optional 10ml, 100ml)
Sample heating position: 9 positions (circumferential distribution)
Injection valve quantitative ring specification: 1ml (optional 0.5ml, 3ml)
Heating range of headspace bottle: 5 ℃ to 185 ℃ above room temperature, set in increments of 1 ℃
Heating range for injection valve and quantitative loop: 5 ℃ to 185 ℃ above room temperature, with increments of 1 ℃
Heating range of sample transmission line: 5 ℃ to 200 ℃ above room temperature, set in increments of 1 ℃
The relative standard deviation (RSD) of peak area for injection is ≤ 1.5% (sample is 0.02% ethanol aqueous solution, N=5)
Activate the dual channel interface of the chromatograph and data processing workstation
Headspace bottle specification: 20ml (optional 10ml, 100ml)
Sample heating position: 9 positions (circumferential distribution)
Injection valve quantitative ring specification: 1ml (optional 0.5ml, 3ml)
Heating range of headspace bottle: 5 ℃ to 185 ℃ above room temperature, set in increments of 1 ℃
Heating range for injection valve and quantitative loop: 5 ℃ to 185 ℃ above room temperature, with increments of 1 ℃
Heating range of sample transmission line: 5 ℃ to 200 ℃ above room temperature, set in increments of 1 ℃
The relative standard deviation (RSD) of peak area for injection is ≤ 1.5% (sample is 0.02% ethanol aqueous solution, N=5)
Activate the dual channel interface of the chromatograph and data processing workstation
DK-3001AMain features of the semi-automatic headspace sampler
Uniformly distributed sample heating positions reduce temperature gradients between different pore positions and improve the stability of analysis results.
The sampling pipeline and injection valve have a blowback function to prevent cross contamination between samples;
The quantitative loop of the injection valve and the controllable temperature of the sample transmission line are used to avoid condensation of the sample during transmission
The sampling pump and injection valve are combined for negative pressure sampling, without the influence of external gas additives, and have high sensitivity;
Equipped with over temperature and power-off protection for safer use;
The injection needle can be freely replaced, making it convenient to connect various models of GC at home and abroad
Uniformly distributed sample heating positions reduce temperature gradients between different pore positions and improve the stability of analysis results.
The sampling pipeline and injection valve have a blowback function to prevent cross contamination between samples;
The quantitative loop of the injection valve and the controllable temperature of the sample transmission line are used to avoid condensation of the sample during transmission
The sampling pump and injection valve are combined for negative pressure sampling, without the influence of external gas additives, and have high sensitivity;
Equipped with over temperature and power-off protection for safer use;
The injection needle can be freely replaced, making it convenient to connect various models of GC at home and abroad
DK-3001AIntroduction to the semi-automatic headspace sampler instrument
The DK-3001A semi-automatic headspace sampler has been highly praised by users for its excellent quality. With its outstanding performance, it has won multiple bids in government procurement bidding projects. In the past three years, it has won bids in the CDC and quality inspection industries in provinces and regions such as Jilin, Inner Mongolia, Hebei, Jiangsu, Anhui, Hunan, Hubei, Jiangxi, Sichuan, Yunnan, Guangxi, and Xinjiang. It has been used by more than 1000 users in the pharmaceutical industry and over 300 users in the judicial evidence system.