Instrument characteristics | ![]() |
||||||||
Ø Dual channel isolation technology Ø Low battery remote transmission Ø Serial intelligent sensor interface Ø Automatic transfer of data to FTP Ø 6 analog channel inputs Ø Modbus SCADA connection Ø 1 SDI-12 channel Ø USB data storage for easy transfer of data and programs |
|||||||||
Software Features |
|||||||||
Ø The software is built-in and does not require installation, and can be used on computers with Windows, Mac, and Linux operating systems Ø Setting up instruments through web pages Ø Connect to the instrument via Ethernet cable, USB data cable Ø Intuitive graphical interface Ø Simple setup interface, convenient for users of all levels Ø Can view real-time and historical data |
|||||||||
application area |
|||||||||
Environmental monitoring, system development and integration, agricultural research, meteorological stations, total energy monitoring, environmental monitoring, temperature profile monitoring, aquaculture, mechanical testing, program monitoring, etc | |||||||||
System Introduction | |||||||||
Display and buttons Type: LCD display, 2 lines of 16 characters, backlight; Display function: channel data, alarm information, system status; Button: View display information and operation functions through 6 buttons; Signal LED lights: 4 signal lights, indicating sampling, hard disk, alarm information, and power supply respectively; Software version upgrade Upgrade software through RS232, Ethernet cable, USB or USB flash drive; clock Basic resolution: 200 µ s; Accuracy: ± 1 minute per year (in an environment with a 0 ℃ value of 40 ℃), ± 4 minutes per year (in environments with -40 ℃ to 0 ℃ and 40 ℃ to 70 ℃); power supply External power supply range: 10 to 30Vdc; Peak power: 6W (12Vdc 0.5A); Average electrical loss The relationship between sampling frequency and power consumption when using a 12Vdc external power supply is shown in the following table:
basic feature Numerical shell: Zinc aluminum alloy; Size: 180 x 137 x 65mm; Weight: 0.9kg; Operating temperature: -40 ℃ to 70 ℃; Operating humidity:<85%, water vapor does not condense; Note: Low and high temperature environments can reduce battery life,LCDThe working temperature of the display screen is-15℃ to50℃. |
|||||||||
analog channel |
|||||||||
The DT82E has 2 analog channels, each of which can be connected to a three wire or four wire input, two independent two-wire inputs, or three single ended two-wire inputs. The specific number of connections is as follows: Two wire single ended channel: 6; Two line differential channels: 4; Three or four differential channels: 2; Basic input range The basic input voltage, current, resistance, and frequency range that can be measured by DT80G are as follows:
Note: The data collector has an automatic range switching function, which can switch between three ranges. The basic input voltage, current, resistance, and frequency accuracy that DT82E can measure are as follows:
Note: Accuracy relative to full scale. Sampling information In order to ensure measurement accuracy and suppress the influence of noise, a line frequency period greater than 50/60Hz is integrated. Maximum sampling speed: 25Hz; Effective resolution: 18 bits; Linearity: 0.01%; Common mode rejection: 90dB; lineSexual stringing inhibition: 35dB. input Channel isolation: 100V (relay open state); Analog component isolation: 100V (photoelectric isolation); Input impedance: 100K Ω,> 100MΩ; Common mode range: ± 3.5V, or ± 35V in the 30V range Sensor excitation Simulation channel excitation: optional 250 µ A or 2.5mA precision current source, 4.5V voltage, switchable external power supply; Universal excitation: The 12V power supply (maximum 150mA) can be turned on and off to power sensors and accessories, and the 5V power supply (maximum 25mA) can be turned on and off to power analog channels. |
|||||||||
Analog sensor |
|||||||||
Introduce several common sensors, but the sensors that DT82E can connect to are not limited to the following types. thermocouple Thermocouple types: B, C, D, E, G, J, K, N, R, S, T type; Thermocouple calibration: ITS-90; RTDs RTD material type: Pt,Ni,Cu; Resistance range: 10 Ω to 10K Ω; thermistor Thermistor type: YSI400xx series; Resistance range: < 10kΩ Note 1: Other types of thermistors are also supported. Note 2: The measurement range can be expanded by parallel resistors. Single chip temperature sensor Support type: LM34-60,AD590/592,TMPxx,LM135/235/335; Strain gauges and bridge sensors Configuration: 1/4 bridge, 1/2 bridge, and full bridge; Excitation: voltage or current; 4-20mACurrent loop Internal 100 Ω or external shunt resistor. |
|||||||||
DIGITAL CHANNEL | |||||||||
digital input/output 4 bidirectional channels Input type: 4 logic levels (maximum 20/30V); Output type: 3 field-effect transistors (maximum: 30V, 100mA), 1 logic output; Relay 1 direct self-locking relay (maximum: 30Vdc, 1A). |
|||||||||
counting channel |
|||||||||
Low speed counting 4-channel counter, shared with the digital channel; The low-speed counting function does not work in sleep mode. Model: 32-bit; Maximum counting rate: 10Hz; Dedicated counting input 4 high-speed inputs Model: 32-bit; Maximum counting rate: 100kHz; Input type: 2 logic level inputs (maximum ± 30V). 2 magnetic induction (maximum ± 10V) sensitive inputs (10mV). |
|||||||||
Serial channel |
|||||||||
SDI-12 One SDI-12 channel shared with the digital channel, each SDI-12 channel can connect more than 10 SDI-12 sensors; Universal Serial Sensor It is very convenient to record data from sensors and data streams. Available ports: Host RS232 port; Baud rate: 300 to 115200. Note: When using a serial sensor channel, the host port cannot be used for communication. |
|||||||||
Calculation channel |
|||||||||
The calculation channel can perform arithmetic, trigonometric, correlation, logical, and statistical analysis on the data collected by the data collector from analog, digital, or serial channels. | |||||||||
call the police |
|||||||||
Condition: Below, above, within range, or outside range; Delay: optional alarm response time; Action: Digital output, transmitting information or executing any datataker command. |
|||||||||
Data Collection List |
|||||||||
Number of schedules: up to 11; Sampling interval for schedule: Each schedule has a separate sampling time interval, ranging from 10ms to days. |
|||||||||
Data Storage | |||||||||
Built-in storage Storage space: 128MB, capable of storing approximately 10 million pieces of data (large memory space can be customized); External storage device USB 1.1, USB 2.0 and other USB flash devices. |
|||||||||
Communication panel |
|||||||||
Ethernet port Panel: 10Mbps; Protocol: TCP/IP, Modbus protocol; hostRS232port Speed: 300 to 115200 baud rate (default 57600); Flow control: hardware (RTS/CTS); Software (XON/XOFF): None Handshake protocol: DCD,DSR,DTR,RTS,CTS; Modem support: automatic answering and dialing; Protocol: ASCII command, TCP/IP (PPP), Modbus protocol, serial sensor; |
|||||||||
Network services(TCP/IP) |
|||||||||
Use Ethernet port or host RS232 port Command panel: Enter the ASCII command panel of DT82E through TCP/IP; Network server: Accessing existing data and data collection status through web pages, setting up user specific display interfaces, and downloading CSV format data; Modbus server (controlled end): obtains data and data acquisition status through Modbus client; FTP server: retrieves stored data through a browser or FTP client; |