Desktop spectrophotometer TS8216
Desktop spectrophotometer TS8216
Product details

The desktop spectrophotometer TS8216 is a spectrophotometer developed by 3nh using independent spectroscopic core technology. It adopts a dual array CMOS image sensor with high sensitivity and a wide spectral response range, making the testing more accurate. The repeatability Δ E * ab of the TS8216 desktop spectrophotometer can be easily controlled within 0.01, and the inter stage difference Δ E * ab can be controlled within 0.12. The data is stable and reliable, and can be used for accurate color analysis and transmission in the laboratory.

Characteristics of TS8216 desktop spectrophotometer

1. Micro pore diameter

The TS8216 desktop spectrophotometer provides reflection: Φ 0.3mm/Φ 0.5mm/Φ 1mm (select only one aperture) transmission: Φ 8mm/Φ 4mm (select only one aperture), used for chromaticity control of small area reflection samples and small capacity transmission samples.

2. Adopting the internationally recognized D/8 structure, compatible with SCI/SCE measurement, and supporting rapid measurement of SCI+SCE simultaneously

The TS8216 desktop spectrophotometer adopts the widely applicable D/8 illumination observation conditions and SCI/SCE (including mirror reflection/excluding mirror reflection) synthesis technology internationally, supporting rapid measurement of SCI+SCE simultaneously.

11.png

3. Dual array CMOS image sensor

It has high sensitivity and a wide spectral response range, ensuring the measurement speed, accuracy, stability, and consistency of the instrument.

4. Multiple color measurement spaces, multiple observation light sources

The TS8216 desktop spectrophotometer provides CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, β xy, DIN Lab99 color spaces, as well as D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30 observation light sources to meet special measurement needs under different measurement conditions.

5. Adopting a combination of full spectrum LED light source and UV light source

The full band balanced LED light source ensures sufficient spectral distribution in the visible light range, avoiding spectral loss of white LED in specific bands, ensuring instrument measurement speed and accuracy of measurement results. The professional UV light source ensures more reliable UV testing.

12.jpg

6. Measurement Verification Report

Each TS8216 desktop spectrophotometer has undergone calibration testing, and the instrument is calibrated according to the measurement standards of authoritative calibration departments before leaving the factory. The measurement data is traced back to the National Institute of Metrology to ensure the authority of the instrument's testing data.

7. Industrial grade high-definition touch screen, simple and easy-to-use user interface

Adopting a 7-inch industrial grade high-definition touch screen, the operation is smooth, and the simple and easy-to-use user interface makes the operation comfortable, convenient, and easier to get started.

8. Color management software

The TS8216 desktop spectrophotometer paired with SQCX quality management software is suitable for quality monitoring and color data management in various industries. Digitize user color management, compare color differences, generate test reports, provide multiple color space measurement data, and customize customer color management work.

13.jpg

Technical parameters of TS8216 desktop spectrophotometer

PRODUCT MODEL TS8216
Illumination Reflection: D/8 (diffuse illumination, 8 ° direction reception);
SCI/SCE measurement; Including UV/exclusion UV measurement;
Transmission: D/0 (diffuse illumination, 0 ° direction reception)
SCI/SCE measurement; Including UV/exclusion UV measurement;
Haze (ASTM D1003);
Complies with the standard CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7
characteristic Used for chromaticity control of small area reflective samples and small capacity transmissive samples.
Integral sphere size Φ154mm
lighting source 360~780nm combination LED light source, 400nm cutoff light source, 420nm cutoff light source
Spectral method Concave grating
a sensor 256 pixel dual array CMOS image sensor
Measuring wavelength range 360~780nm
wavelength interval 10nm
Half bandwidth 5nm
Reflectance measurement range 0~200%
measuring aperture Reflection: Φ 0.3mm/Φ 0.5mm/Φ 1mm (select only one aperture)
Transmission: Φ 8mm/Φ 4mm (select only one caliber)
Light containing method Reflective SCI/SCE, transmissive SCI/SCE
color space CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
colour-difference formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, DINΔE99, ΔE(Hunter)
Other chromaticity indicators WI(ASTM E313,CIE/ISO,AATCC,Hunter),
YI(ASTM D1925,ASTM 313),
The same color spectral index Mt,
Stain fastness, color fastness, strength, coverage,
APHA/Hazen/Pt Co (Platinum Cobalt Index), Gardner Index
8 degrees glossiness, 555 tone classification, haze (ASTM D1003), Saybolt index, ASTM D1500 color code, Chinese Pharmacopoeia color code
Observer's perspective 2°/10°
Observing light source D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30
display Spectral chart/data, sample chromaticity value, color difference value/graph, color chart, color simulation, qualified/unqualified results, color deviation
Time About 2.4 seconds (testing SCI/SCE simultaneously takes about 5 seconds)
repeatability Spectral reflectance: Φ1mm/SCI, Standard deviation within 0.08%
Chromaticity value: Φ 1mm/SCI, Δ E * ab within 0.15 (after preheating and calibration of the instrument, measure the average value of the whiteboard 30 times at intervals of 5 seconds)
Spectral transmittance: Φ8mm/SCI, Standard deviation within 0.1%
Chromaticity value: Φ 8mm/SCI, Δ E * ab within 0.18 (after preheating and calibration of the instrument, measure the average value of the whiteboard 30 times at intervals of 5 seconds)
Inter station difference Φ 1mm/SCI, Δ E * ab within 0.25 (average value measured on 12 color plates of BCRA series II)
size Length X width X height=370X300X200mm
weight About 9.6kg
Power supply mode DC 24V, 3A power adapter for power supply
Lighting source lifespan More than 3 million measurements in 5 years
display TFT true color 7-inch, capacitive touch screen
interface USB, Bluetooth ® 5.0, Print Serial Port
Store data 5000 standard samples and 40000 test samples (SCI/SCE count as one data point)
language Simplified Chinese, Traditional Chinese, English, (Customizable in German, French, Spanish)
Operating temperature range 0~40℃(32~104°F)
Storage Temperature Range -20~50℃(-4~122°F)
Standard accessory Power adapter, manual, quality management software (official website download), data cable, standard calibration board, black calibration box, transmission black baffle, sample holder, single reflection aperture, transmission testing fixture component, single transmission testing fixture component
Optional Accessories Micro printers, inverted testing fixtures for instruments, culture dishes
Note: If there are any changes, no further notice will be given
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!