Tengzhou Zhongke Spectral Analysis Instrument Co., Ltd
Home>Products>Determination of β - Pinene Content in Qingqiao Volatile Oil by Capillary Gas Chromatography
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18663278921
  • Address
    No. 20, Xibeitan, Tengzhou City, Shandong Province
Contact Now
Determination of β - Pinene Content in Qingqiao Volatile Oil by Capillary Gas Chromatography
Product Introduction: Capillary Gas Chromatography is used to determine the content of β - pinene in the volatile oil of Qingqiao. The crude extract o
Product details
brand ZKP/Zhongkepu

[Product Introduction]Establish a method for determining the content of β - pinene in the volatile oil of Qingqiao and measure its content. Method: Purification and crude extraction of volatile oil from Qingqiao were carried out using anhydrous ethanol; The content of β - pinene was determined by gas chromatography. Result: Cyclohexanone was used as the internal standard; The linear relationship of β - pinene reference substance is good within the concentration range of 0.3-4.4mg · mL ^ -1 (r=0.9999); The RSD of precision for the reference substance and sample were 0.95% and 0.99%, respectively (n=5); The average recovery rate was measured to be 98.5%, with an RSD of 1.2% (n=5); The content of β - pinene in the volatile oil of Qingqiao ranges from 10.2% to 10.2%, with an average content of 10.2% and an RSD of 1.0%. Conclusion: This method is fast, accurate, reliable, simple and feasible, and can be used for quality control of Qingqiao volatile oil.

Analysis spectrum of β - pinene

























GC-2010Type gas chromatographDetailed information:

1.High cost performance ratio, complete dual air circuit design: can be installed simultaneouslyFIDTCDFPDperhapsFIDTCDECDThree detectors can be installed simultaneously, including one packed column and one capillary column, as well as optional types such as dual capillary and dual amplifier. Choose from five detectors and methane converters, ceramic or quartz nozzles.

2Adopting brand new doubleCPUDesign, original Japanese high integration electronic circuit technology,Excellent reliability and anti-interference ability,The precision of temperature control has reached0.1, with higher display accuracy0.01And it can simultaneously display the power consumption percentage of each heating part. Six channel temperature turbidity automatic alarm and automatic power-off protection function.
3.Computer full control,Digital communication; Large screen LCDLCDDisplay; Menu based operation; Stage programmed heating system; Automatic rear door for rapid cooling; Near room temperature operation;6Road temperature control; Fault self diagnosis over temperature protection,10Complete functions including file storage, stopwatch timing, and over temperature protection
4.The detector adopts a modular design, which has the characteristics of high sensitivity, low noise, good repeatability, and wide linear range.
5. Various caliber packed columns can be configured, including column head injection, liner injection, and capillary split/no split injection.

Main technical specifications of the detector

Hydrogen flame ionization detector(FID

(1)Cylindrical collection electrode structure design, quartz nozzle, responsive*

(2)Detection limit:≤8×10g/s(HEXADECANE/isooctane

(3)Baseline noise:≤2×10A

(4)Baseline drift:≤2×10A/30min

(5)Linear:≥10

Thermal conductivity detector(TCD)

(1)Adopting a semi diffusive structure

(2)The power supply adopts constant current control mode

(3)Sensitivity:≥2500mV·ml/mg(HEXADECANE/isooctane.

(4)Baseline noise:≤20μV.

(5)Baseline drift:≤100μV/30min.

Note: External dimensions: 660 * 460 * 465mm Machine weight: 60 kg Input power supply: AC 220V ± 10% 50HZ 2KW