Detu testo310 flue gas analyzerIntroduction:
Smoke measurement
Smoke measurement is the core of smoke analysis, which can directly measure CO and O2Concentration, as well as environmental and flue gas temperature. All other parameters, such as CO2The value, efficiency, and smoke loss are all calculated based on the above data.
Environmental CO measurement
Environmental CO measurement is a safety check that can detect the presence of smoke spillage near the heating system. If there is overflow, it will cause an increase in CO concentration in the boiler room and bedroom. This measurement poses a threat to personal safety, therefore it needs to be taken first.
Pull force measurement
Pull force measurement can ensure that the smoke emitted from the heating system is discharged from the flue. This measurement menu will detect whether there is sufficient negative pressure in the heating system. At the same time, the temperature of the flue gas will also be measured.
Differential pressure measurement
Differential pressure measurement is a test of the gas supply to the boiler. Specifically, it is the difference between the gas path pressure and the ambient pressure. This measurement is important for regulating the injection pressure.
Detu testo310 flue gas analyzercharacteristic:
Durable and sturdy: The instrument is lightweight and durable - very suitable for daily use
Backlight display: Two line display with clear menu structure. Easy to operate, clear and easy to read.
Automatic sensor zeroing: After turning on, the gas sensor automatically zeros in just 30 seconds. If not needed, it can be cancelled.
Lithium ion rechargeable battery: Lithium ion rechargeable battery (1500 mAh), can be used for up to 10 hours after being fully charged, and can be charged via USB.
Probe filter element: can quickly and easily replace the probe filter element
Magnetic attraction: The back of the instrument is equipped with magnetic attraction, which can be easily fixed on the burner.
Condensation tank: The instrument's built-in condensation tank - can be quickly and easily emptied.
Printer: Print and archive through infrared interface.
Parameters:
range | Accuracy ± 1 digit | resolution | Response time t90 | |
Temperature (smoke) | 0 - 400.0 °C | ±1 °C (0 -100 °C) ± 1.5% measurement value (>100 ° C) |
0.1 °C | < 50 s |
Temperature (ambient temperature) | -20 to +100.0 °C | ± 1 °C | 0.1 °C | < 50 sec |
Pull force measurement | -20.00 to +20,00 hPa | ± 0.03 hPa (-3.00 to +500 hPa) ± 1.5% measurement value (other ranges) |
0.01 hPa | |
Pressure measurement | -40,00 to +40.0 hPa | ± 0.5 hPa | 0.1 hPa | |
O2Measurement | 0,0 to 21.0 vol.% | ± 0.2 vol.% | 0.1 Vol. % | 30 sec |
Measurement (none) H2Compensation) |
0 to 4000 ppm | ±20 ppm (0 to 400 ppm) ± 1.5% measured value (401 to 2000 ppm) ± 10% measurement value (2001 to 4000 ppm) |
1 ppm | 60 sec |
Environmental CO measurement | 0 to 4000 ppm | ±20 ppm (0 - 400 ppm) ± 1.5% measured value (401 to 2000 ppm) ± 10% measurement value (2001 to 4000 ppm) |
1 ppm | 60 sec |
Combustion efficiency (Eta) | 0 to 120 % | 0.1 % | ||
Smoke loss | 0 to 99,9 % | 0.1 % | ||
General technical data | ||||
storage temperature | -20.0 °C to +50,0 °C | |||
operate temperature | -5 to +45 °C | |||
power supply | Rechargeable battery: 1500 mAh, power supply 5V/1A | |||
Memory | No memory | |||
screen display | 2-line backlit display | |||
Weight, including probe | About 700 g | |||
size | 201 x 83 x 44 mm | |||
warranty |
Measuring instruments, smoke probes, gas sensors: 12 months Thermocouples: 12 months Rechargeable batteries: 12 months |