Diane ICS1500 ion chromatograph
Introduction to Diane ICS1500 Ion Chromatography Instrument: ICS1500 Analysis Pump and Transport Device Type: Series reciprocating pump, microprocesso
Product details
Product Introduction

Diane ICS1500 ion chromatographInstrument Introduction:
ICS1500
Analyze pumps and conveying devices
Type: Series reciprocating pump, microprocessor controlled fixed stroke, variable speed
Structure: chemically inert, metal free PEEK pump head and flow path pH 0-14, compatible with aqueous solutions and reverse phase solvents

Control mode: Fully controlled through the front panel or chameleon software; Can choose TTL or relay switch
Operating pressure: 35Mpa (5000psi)
Pressure fluctuation:<1.0%
Flow rate range: 0.00-5.0mL/min in increments of 0.01
Traffic accuracy:<0.1%
Traffic accuracy:<0.1%
Piston seal cleaning: dual pump heads, continuous cleaning when connected to detergent solution
Pressure range: upper limit 0-35Mpa or 0-5000psi; Can set upper and lower limit alarm function
Vacuum degassing (optional): single channel, automatic
Conductivity detection circuit and flow cell
Type: Microprocessing - Digital Signal Control Processor
Detection frequency: 100Hz
Resolution: 0.00238nS
Full scale output range: 0-15000 μ S
Temperature compensation: with temperature compensation function
Temperature range: Environment+7 ℃ to 55 ℃
Temperature stability of conductivity cell: ≤ 0.01 ℃
Pool electrode: passivated 316 stainless steel
Conductivity cell material: chemically inert polymer material
Conductivity cell volume:<1 μ L
Pool heating exchanger: low differential quantity
Pool operating pressure: 10MPa (1500psi)
Suppressor control: AES, 0-150mA, 1mA increment
SRS, 0-500mA, 1mA increments
The conductivity cell is compatible with methane sulfonic acid
Column heating (optional accessory)
Operating temperature range: Environment+5 ℃ to 60 ℃
Temperature stability: ± 1 ℃
Temperature accuracy: ± 2 ℃ for external calibration thermometer at 40 ℃


Physical specifications
Power supply: 100-240V AC, 50/60Hz (automatic induction and adjustment)
Voltage range: 90-265V AC, 47-63Hz
Operating temperature: 4-40 ℃ (40-104 ℉)
Operating humidity range: 5-95% relative humidity, no condensation
Control mode: chameleon software control, can choose TTL or delay switch.
Two delayed outputs, two TTL outputs, four programmable inputs
USB communication port: one input, two fixed USB input ports
Leakage detection: built-in, optical sensor
Size (h × w × d) 56.1cm × 22.4cm × 53.3cm (22.1in × 8.8in × 21in)
Weight: 24.5 kg (54 lbs)


Technical parameters:
1. Flow rate range: 0.00-5.0mL/min in increments of 0.01
2. Operating pressure: 35Mpa (5000psi)
3. Conductivity detection output range: digital signal range 0-15000 μ S
4. High definition large screen touch control display screen
5. Automatic regeneration biofilm suppression technology
6. Optional AS50 automatic sampler


Main features:
1. Column heating, operating temperature range: environment+5 ℃ to 60 ℃
2. Control mode: Controlled through the front panel or chameleon software
3. High capacity analytical column technology
4. RFID free ion chromatography
5. Stable after-sales service and application support system

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!