Diaphragm differential pressure transmitter
Diaphragm differential pressure transmitter
Product details

Detailed Introduction

oneDetailed information on HL3051DPMF diaphragm differential pressure transmitter:
Sealing diaphragm is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the differential pressure transmitter. It is connected to the transmitter by a capillary tube filled with fluid. The HL3051DPMF diaphragm sealed differential pressure transmitter is used to measure the flow rate, liquid level, density, and differential pressure of liquids, gases, and vapors, and then outputs a 4-20mA DC signal corresponding to the measured differential pressure. It can also communicate with the handheld device for remote setting and monitoring.

2、 Product Selection List:
model DESCRIPTION
HL3051DPMF Intelligent dual flange differential pressure transmitter
code authentication
A Used for non explosion proof purposes
1 ExiaⅡCT6
2 ExiaⅡCT4
3 ExdⅡBT6
Please contact the company for other certifications or certification information that is currently being applied for
code code
A 4…20mA
B Digital 4-20mA
C 4…20mA, HART
code display
A no display
L LCD
code Shell, cable entry, protection level
A Aluminum 14, M20 × 1.5, IP66/67
B Aluminum 14, G1/2,IP66/67
C Aluminum 14, 1/2NPT, IP66/67
code Rated range of sensor
7D 100mbar/10kPa/1mH2O
7F 500mbar/50kPa/5mH2O
7H 3bar/300kPa/30mH2O
7L 16bar/1.6MPa/160mH2O
7M 40bar/4MPa/400mH2O
code Calibration, Unit
1 Calibrate the rated range, mbar/bar
2 Calibrate the rated range, kPa/MPa
3 Calibrate the rated range, mmH2O/mH2O
code Membrane material
1 316L
2 Alloy C-276
3 Monel
4 Tantalum film
6 316L with PTFE coating (not suitable for vacuum applications, only for non explosion proof areas)
X Other special requirements
For other special requirements for membrane, please contact the company
code Process connection EN/DIN flange code Process connection ANSI flange
EA1 DN25 PN10/40 B1 NA1 1”300 lbs RF
EA2 DN25 PN64/160 E NA2 1”400/600 lbs RF
EA3 DN25 PN250 E NA3 1”900/1500 lbs RF
EA4 DN25 PN400 E NA4 1”2500 lbs RF
EH1 DN50 PN25/40 A NH1 2”300 lbs RF
EH2 DN50 PN100/160 E NH2 2”400/600 lbs RF
EH3 DN50 PN250 E NH3 2”900/1500 lbs RF
EH4 DN50 PN400 E NH4 2”2500 lbs RF
EQ1 DN80 PN25/40 A NQ1 3”300 lbs RF
EQ2 DN80 PN100 B1 NM1 4”300 lbs RF
EM1 DN100 PN100 B1E
EAX Other special requirements
For other special requirements for connecting threads, please contact the company
code Insertion depth of the cylinder code Insertion depth of the cylinder
C0 not have C4 2”
C1 50mm C5 4”
C2 100mm C6 6”
C3 200mm C7 8”
code Fill Fluid code Fill Fluid
A silicone oil C Inert oil
B vegetable oil D High temperature oil
code capillary length
A not have
XX XX is written in numbers, with 01 representing 1m and 99 representing 99m
code mounting bracket
A not have
U Pipe installation bracket

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!