Diesel single-stage fire pump set
1、 Product introduction: XBC-KDS diesel engine fire pump set is the latest national standard GB6245-2006 "Performance Requirements and Test Methods fo
Product details

1Product Introduction:

XBC-KDS typeXBCIt is the latest national standard GB6245-2006 "Performance Requirements and Test Methods for Fire Pumps". This series of products has a wide range of head and flow, fully capable of meeting the fire water supply needs of various industrial and mining enterprises such as warehouses, docks, airports, petrochemicals, power plants, liquefied gas stations, and textiles. The advantage is that in the event of a sudden power outage in the building's electrical system, the electric fire pump cannot be started, and the diesel fire pump automatically starts to provide emergency water supply.
XBC-KDS typeDiesel fire pumpIt is composed of a diesel engine and a fire pump, and the pump set is a horizontal, double suction, single-stage centrifugal fire pump. It has the characteristics of high efficiency, wide performance range, safe and stable operation, low noise, long service life, and easy installation and maintenance. For transporting clean water or other liquids with physical and chemical properties similar to water. It can also be used to transport hot water, oil, corrosive or abrasive media by changing the material and sealing form of the pump flow components and adding a cooling system.

IIproduct overview:

nProduct model:XBC-KDS

nBrief introduction: Inlet and outlet diameter32-500mm, flow rate 5-6000m3/h, lift 8-200m

nStructural methods: mobile, fixed, containerized

nDiesel engine speed:960-3000r/min

nDiesel engine brands: Shangchai, Dongfeng Cummins, Deutz, Fiat, Ryan, Weifang Kefa, etc.

nMain applications: fire protection system, industrial water supply system, hot water circulation, etc.

IIIUsage conditions:

1) Environmental temperature ≤ 50, medium temperature≤80

2)The medium density shall not exceed 1240kg/m3.

3)The liquid level must be higher than the pump inletProhibit idling without liquid.

4Model Description:

Diesel engineSingle Stage Pump XBC- KDS 100 –80–160Impeller diameter:160m

Traffic:80m Inlet diameter:100mm

4Product physical picture:

5Product Configuration

Product Configuration Diagram

Equipment name

quantity

notes

Diesel engine

1 unit

Match with the pump end

Single stage fire pump

1 piece

Shanghai Huanghe Pump Industry

High elasticity column pin coupling

1 payment

Shanghai Huanghe Pump Industry

Pump set common channel steel base

1 set

Shanghai Huanghe Pump Industry

Independent fuel tank

1 piece

Shanghai Huanghe Pump Industry

Battery

2 pieces

Camel

muffler

1 piece

random

Diesel engine control cabinet

1 unit

Overload alarm display, start and stop, emergency stop, fault alarm, etc. for speed, oil pressure, voltage, water temperature, runaway, etc.

Optional components:

Export shock resistant pressure gauge

1 piece

Installed on a 0.5m iron pipe

Export rubber steel wire hose

1 item

Length 1 meter

Imported bottom valve (filter head)

1 piece


VIStructural reference diagram and working principle:

The XBC-KDS diesel engine single-stage fire pump set has inlet and outlet ports on the pump body. During maintenance, only the pump head needs to be removed, and the rotor components can be moved for maintenance operations without dismantling the pipeline. Very convenient, the diesel engine can be installed on the left or right end as needed, making it easy to install on site. Structurally shortening the axial dimensions of rotor components results in better shaft rigidity and more stable and reliable operation. There is a pump body sealing ring, and the impeller sealing ring is an optional condition.
Working conditions: allowable work pressure2.5Mpa, according to the maximum pressure that the pump casing can withstand, the materials of the pump body and pump cover are ductile iron (2.0Mpa), cast steel (2.5Mpa), etc.

7Fire automatic control cabinet:

Unit control system

Control system model

Zhongzhi 410

Performance points

410: The control system is mainly used to control the manual and automatic control of the diesel engine water pump unit, and to automatically switch to start the diesel engine after a power outage. It integrates digitization, intelligence, and networking, and can be used for start stop control of diesel engine pump sets, real-time monitoring and data measurement, alarm protection, and automatically controls the start of diesel engine pump sets in case of deviation from the set value or power failure in the mains power supply, achieving the conversion between mains power and diesel power.

With a microprocessor as the core and advanced technology applied, it is equipped with the "three remote" function, stable performance, and reliable operation.

Zhongzhi 410 (standard)

● Implement precise measurement and display functions for the operating parameters of diesel engine pump sets


● Operation status and configurable input fault point LED indication, various measurement parameters and alarm large screen LCD display


Extremely wide DC working power input (8-35V)


● Optional manual and automatic (remote control) working modes


● Equipped with multiple control and protection functions, multiple pressure and temperature display units


● Equipped with real-time calendar, clock, and accumulated running time functions


● Equipped with network communication function, remote control can be achieved through RS485 interface


8Technical performance parameters:

Model

internet traffic

lift

rotational speed

shaft power

Caliber (mm)

(mз/h)

(m)

(r/min)

(KW)

inhale

discharge

XBC-KDS50-32-125

12.5

20

2900

2.2

50

32

6.3

5

1450

0.55

50

32

XBC-KDS50-32-160

12.5

32

2900

3

50

32

6.3

8

1450

0.55

50

32

XBC-KDS50-32-200

12.5

50

2900

0.5

50

32

6.3

12.5

1450

0.75

50

32

XBC-KDS50-32-250

12.5

80

2900

11

50

32

6.3

20

1450

1.5

50

32

XBC-KDS65-50-125

25

20

2900

3

65

50

12.5

5

1450

0.55

65

50

XBC-KDS65-50-160

25

32

2900

5.5

65

50

12.5

8

1450

0.75

65

50

XBC-KDS65-40-200

25

50

2900

7.5

65

40

12.5

12.5

1450

1.1

65

40

XBC-KDS65-40-250

25

80

2900

15

65

40

12.5

20

1450

2.2

65

40

XBC-KDS65-40-315

25

125

2900

30

65

40

12.5

32

1450

4

65

40

XBC-KDS80-65-125

50

20

2900

5.5

80

65

25

5

1450

0.75

80

65

XBC-KDS80-65-160

50

32

2900

7.5

80

65

25

8

1450

1.5

80

65

XBC-KDS80-50-200

50

50

2900

15

80

50

25

12.5

1450

2.2

80

50

XBC-KDS80-50-250

50

80

2900

22

80

50

25

20

1450

3

80

50

XBC-KDS80-50-315

50

125

2900

37

80

50

25

32

1450

5.5

80

50

XBC-KDS100-80-125

100

20

2900

11

100

80

50

5

1450

1.5

100

80

XBC-KDS100-80-160

100

32

2900

15

100

80

50

8

1450

2.2

100

80

XBC-KDS100-65-200

100

50

2900

22

100

65

50

12.5

1450

4

100

65

XBC-KDS100-65-250

100

80

2900

37

100

65

50

20

1450

5.5

100

65

XBC-KDS100-65-315

100

125

2900

75

100

65

50

32

1450

11

100

65

XBC-KDS125-100-200

200

50

2900

45

125

100

100

12.5

1450

7.5

125

100

XBC-KDS125-100-250

200

80

2900

75

125

100

100

20

1450

11

125

100

XBC-KDS125-100-315

200

125

2900

110

125

100

100

32

1450

15

125

100

XBC-KDS125-100-400

100

50

1450

30

125

100

XBC-KDS150-125-250

200

20

1450

18.5

150

125

XBC-KDS150-125-315

200

32

1450

30

150

125

XBC-KDS150-125-400

200

50

1450

45

150

125

XBC-KDS200-150-250

400

20

1450

37

200

150

XBC-KDS200-150-315

400

32

1450

55

200

150

XBC-KDS200-150-400

400

50

1450

90

200

150

9Product features:

1. Automatic start: The diesel water pump unit can automatically start and operate at full load within 5 seconds after receiving a fire alarm/pipeline pressure/power outage/or other start signals;

2. Automatic charging: The battery can be charged automatically by the mains power or diesel engine charging motor to ensure the smooth start-up of the unit;

3. Automatic alarm: It automatically alarms and protects against faults such as low oil pressure and high water temperature in diesel engines, and alarms and shuts down when overspeed occurs;

4. Automatic preheating: put the diesel engine in a hot standby state to ensure emergency operation;

5. Direct connection: Diesel water pump units below 360kw adopt the technology of direct connection between diesel engine and water pump through elastic coupling, which reduces the number of fault points and greatly shortens the starting time of the unit, increasing the reliability and emergency performance of the unit;

6. Users can also request to set other alarm outputs (non-standard supply);

7. Equipped with telemetry, remote signaling, and remote control functions (non-standard supply);


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!