Changsha Aikesipu Instrument Equipment Co., Ltd
Home>Products>Dingyang SIGLENT SDS2304X Fluorescence Oscilloscope
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    611 Xiangyu Smart South Building, Kaifu District, Changsha City, Hunan Province
Contact Now
Dingyang SIGLENT SDS2304X Fluorescence Oscilloscope
Introduction: Dingyang SIGLENT SDS2304X Fluorescence Oscilloscope Specification Parameters Bandwidth 300 MHz Real time Sampling Rate 2 GSa/s Channel C
Product details

Dingyang SIGLENT SDS2304X Fluorescence Oscilloscope Specification Parameters

bandwidth 300 MHz
Real time sampling rate 2 GSa/s
Number of channels 4 + EXT
Storage depth 140 Mpts/CH
Maximum waveform capture rate 500000 wfm/s (Sequence mode)
Vertical resolution 8-bit (equivalent resolution can reach 11 bits in ERES mode)
Input impedance 1 MΩ || 20 pF,50 Ω
Time base range 1.0 ns/div ~ 50 s/div ROLL: 50 ms ~ 50 s/div
Trigger type Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video
Serial data decoding type IIC, SPI, UART/RS232, CAN, LIN
16 digital channels (optional) Maximum sampling rate of 500 Msa/s, storage depth of 14 Mpts/CH
Mathematical operations A +B、A-B、A*B、A/B、FFT、Diff、Intg、Sqrt
automatic measurement 37 automatic measurement functions, supporting measurement statistics, Gathering measurement, Math measurement, History measurement, and Ref measurement
External storage Bitmap storage (. BMP), CSV, binary waveform data (. BIN), setup storage (. SET), Matlab data files (. DAT)
Interface USB Host、USB Device、LAN、Pass/Fail、Trigger Out
screen 8-inch TFT-LCD screen with a resolution of 800 * 480
Maximum input voltage 1 MΩ ≤ 400 Vpk(DC + Peak AC <=10 kHz)
50 Ω ≤ 5 Vrms
size 352 mm * 128 mm * 224 mm (length, width, height)
weight Net weight of 2 channels 3.4 Kg, net weight of 4 channels 3.6 Kg
2-channel gross weight 4.9 Kg, 4-channel gross weight 5.2 Kg

Innovative SPO architecture

Traditional digital oscilloscopes have waveform data processing and display completed in the CPU, which has become the bottleneck for the entire data acquisition, processing, and display. The Dingyang SIGLENT SDS2304X fluorescence oscilloscope based on SPO architecture adopts SIGLENT's independently innovated waveform acquisition and image processing engine, and uses FPGA to complete waveform processing and display, achieving
The waveform capture rate can reach up to 500000 frames per second, enabling the oscilloscope to quickly capture low probability events
256 level waveform brightness level and color temperature display
Digital trigger - low jitter, high trigger sensitivity
Storage depth up to 140 Mpts
By utilizing these features, users can quickly detect occasional spikes and abnormal signals, and identify the root cause of the problem.

Sequential mode

The sequential mode divides the waveform storage space into multiple segments, with each segment storing one trigger frame. It can collect up to 80000 trigger events and minimize the dead time (as small as 2 μ s) within the Sequence cycle, improving the probability of capturing abnormal events.
The waveform collected in Sequence mode can also be replayed through History mode.

History Mode

The historical mode running in the background can record up to 80000 frames of waveforms and view the timestamp of each frame of waveform.
The historical waveform is automatically recorded in real-time, and abnormal events can be observed by replaying the historical waveform at any time. The problem source can be quickly located through the cursor or measurement parameters.
Press the 'History' button on the panel to quickly activate this function.

Integrate 10 one click operations

The Dingyang SIGLENT SDS2304X fluorescence oscilloscope has made the most commonly used functions of users into one click operations, with a total of 10 types, including one click zoom, one click scroll, one click print, one click afterglow, one click measurement, one click enter history mode, one click restore default settings, one click cursor, one click clear, and one click automatic capture.

ERES Enhanced Resolution Mode

The ERES acquisition mode can effectively improve the signal-to-noise ratio and does not rely on the periodicity of the signal and the stability of the trigger point like the average mode.
The Dingyang SIGLENT SDS2304X fluorescence oscilloscope supports ERES mode, with an equivalent resolution of up to 11 bits.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!