Xi'an Dacheng Instrument Co., Ltd
Home>Products>Dissolved oxygen tester
Dissolved oxygen tester
Description: MI190 Large Range Dissolved Oxygen Tester Product Description: MI190 Large Range is suitable for pharmaceutical preparations, food produc
Product details
  • MI190 Large Range Dissolved Oxygen Tester

    Product Description:

    The MI190 Large Range Dissolved Oxygen Tester is suitable for pharmaceutical preparations, food production, and monitoring plants in water Users can measure the dissolved oxygen saturation using mg/L or%
    MI190 can be used for any type of water and can compensate for temperature, altitude, and salinity. The automatic input function allows users to retrieve previous measurement values
    All data can be transmitted to the computer through RS232 or USB ports Can memorize 50 types of sample data
    Mi190 has an automatic calibration feature at 1 or 2 points (at 0 and 100% oxygen saturation), and the tester uses a polarographic probe (MA840/2) to measure oxygen reactions in agriculture
    Assemble MA840/2 DO probe, 2 wires, 2 membranes, MA7041 electrolytic solution (30 mL), 12 VDC power supply, probe holder, and user manual.

    Technical Parameter

    Range O2

    Saturation% O2

    Temperature

    0.00 to 45.00 mg/L (ppm)

    0.0 to 300%

    -5.0 to 55.0°C / 23.0 to 131.0°F

    Resolution O2

    Saturation% O2

    Temperature

    0.01 mg/L (ppm)

    0.1%

    0.1°C / 0.1°F

    Accuracy O2

    Saturation% O2

    Temperature

    ±1.5 Full Scale

    ±1.5 Full Scale

    ±0.4°C / ±0.8°F

    count

    50 second automatic counting or counting as needed

    DO calibration

    1 or 2 points at 0% (MA9070) and 100% (in air) automatic calibration

    temperature compensation

    0.0 to 50.0°C / 32.0 to 122.0°F

    Altitude compensation

    0 to 4000 m; resolution 100 m

    Salinity compensation

    0 to 40 g/L; resolution 1 g/L

    dissolved oxygen electrode

    MA840/2 with DIN connector (included)

    Temperature electrode

    Included in the DO electrode

    calibration

    2-point calibration (0.0 ° C and 50.0 ° C/32.0 to 122.0 ° F)

    LOG ON DEMAND

    More than 50 seconds

    PC Communication

    RS232/USB optical independent interface

    power supply

    12V DC power adapter

    environment

    0 to 50°C / 32 to 122°F; max RH 100%

    size

    230 x 160 x 95 mm

    weight

    0.9 Kg