1. Model Description(CE: PED refers to today)
NXQ □ - □/□ - □
① ②③③②⑤⑥
① Bladder type accumulator
② Structural form: A: Small mouth; AB: Big mouth
③ Nominal volume: liters (L)
④ Nominal pressure: MPa 10~31.5MPa
⑤ Connection form: L: threaded connection; F: Flange connection
⑥ Working medium: Y: hydraulic oil; R: Emulsion
2. Product features
① Structural form: large mouth, small mouth structure
② Fixed method: fastening ring or support ring
③ Installation method: In principle, it should be installed vertically
④ Working medium: petroleum based hydraulic oil, emulsion
⑤ Working temperature: -20~93 ℃
⑥ Capsule filled with gas: nitrogen
model |
Nominal volume |
Basic dimensions |
weight |
||||||||
M |
d |
Φ1 |
Φ2 |
Φ3 |
Φ4 |
n-Φ4 |
L |
Φ |
|||
NXQA(AB)-16/※-※-※ |
16 |
M60×2 |
70 |
50 |
70 |
125 |
158 |
6-Φ21 |
870 |
219 |
51 |
NXQA(AB)-20/※-※-※ |
20 |
1000 |
58 |
||||||||
NXQA(AB)-25/※-※-※ |
25 |
1170 |
68 |
||||||||
NXQA(AB)-32/※-※-※ |
32 |
1305 |
82 |
||||||||
NXQA(AB)-40/※-※-※ |
40 |
1690 |
98 |
||||||||
NXQA(AB)-50/※-※-※ |
50 |
2035 |
118 |
3. Ordering instructions
When placing an order, the full name of the model code must be specified, such as: maximum working pressure of 31.5MPa, nominal volume of 16L, flange connection, using hydraulic oil as the working medium
The standard bladder type accumulator with a small mouth structure is NXQA-10/31.5-F-Y.
If there are special requirements for the bladder type accumulator, please consult with our company.