Shanghai Hanchao Hydraulic Equipment Co., Ltd
Home>Products>EVSA, DSD, DWL and other series of relief valves and pressure reducing valves
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13611879306
  • Address
    Room 1005, No. 1 Lane 628, Lvyuan Road, Jiading District, Shanghai (Rhine Yuedu)
Contact Now
EVSA, DSD, DWL and other series of relief valves and pressure reducing valves
EVSA, DSD, DWL and other series of relief valves and pressure reducing valves
Product details
DESCRIPTION
Parker派克EVSA和VSA系列直动式溢流阀

Parker EVSA and VSA series direct acting relief valves

The structure of Parker's EVSA and VSA series direct acting relief valves is a seat valve with adjustable spring-loaded direct acting damping. There are three selectable maximum pressure regulation levels of 64, 160, and 315 bar. Its function is to open the cone valve when the pressure exceeds the set value of the regulating spring, allowing P → T or A → B to communicate. The integrated shock-absorbing valve core prevents pressure fluctuations in the transition zone. Pressure regulation can be adjusted through adjusting bolts with locking nuts. When necessary, cylinder pin locks can also be used to protect the set values.

Parker派克VB/VM/VS系列直动式压力阀

Parker VB/VM/VS series direct acting pressure valve

The Parker VB/VM/VS series direct acting pressure valve is an adjustable spring-loaded direct acting shock-absorbing piston slide valve with small hysteresis. It can be supplied at pressure levels of 25, 64, 160, 210 bar (NG06) or 64, 125, 210 bar (NG10) with maximum adjustment pressure. The pressure reducing valve has a 3-way structure.

Parker派克DSD系列NG6溢流阀

Parker DSD Series NG6 Overflow Valve

The Parker DSD series NG6 relief valve limits the system pressure by allowing the oil to flow back to the tank through the opening of pressure port P. Valve NG6 is a direct acting type and has P, A, and T ports according to DIN standards. The P port and A port are connected inside the valve body. This direct acting valve can also be used as a pilot valve for a pilot operated relief valve.

Parker派克R系列先导式溢流阀

Parker R-series pilot operated relief valve

The Parker R-series pilot operated relief valve features a sturdy valve body, consisting of a DIN24342 compliant cartridge valve as the main stage and a threaded cartridge valve as the pilot stage. The throttle hole can limit the control oil flow and maintain the stability of the given pressure. The control of oil flow can be achieved through both internal and external controls. It has two types of connection ports available for use.

Parker派克RS系列先导式溢流阀

Parker RS series pilot operated relief valve

The Parker RS series pilot operated relief valve features a sturdy valve body, consisting of a DIN standard NG25 cylindrical plug valve as the main stage and a threaded plug valve as the pilot stage. The electromagnetic directional valve installed on the valve body can be used for electronic pressure relief. The normally open or normally closed reversing switch function can be specified in the order code.

Parker派克DSDU系列先导式溢流阀

Parker DSDU series pilot operated relief valve

The Parker DSDU series pilot operated relief valve limits system pressure by opening the pressure port to allow oil to flow back to the tank. The valves in this structural series have a stable flow pressure characteristic curve, which is used for the safety of accumulator systems. This type of valve has been calibrated and certified by TUV (German Technical Monitoring Association). The corresponding TUV certificate is supplied together with the valve. (See note)

Parker派克VBY*A/VMY*A系列先导式压力阀

Parker VBY * A/VMY * A series pilot operated pressure valve

Parker VBY * A/VMY * A series pilot operated pressure valve is a pilot operated pressure valve with a nominal size of 06, which can be used for stepless pressure regulation. For different functions such as compression force, back pressure, or clamping force, it can maintain a predetermined pressure constant. Its structure is: a pilot pressure valve consists of a pilot stage and a main stage. Adjust the pre compression spring acting on the hardened valve seat and valve cone by adjusting the bolt. The force of the pre compressed spring on the valve cone creates a control pressure between the valve seat and the hardened main stage sliding valve core, which keeps the valve core under the action of the spring in the adjustment position corresponding to the predetermined pressure.

Parker派克DWL/DWK系列减压阀

Parker DWL/DWK series pressure reducing valve

The Parker DWL/DWK series pressure reducing valve can keep the pressure at the secondary end (port A) constant according to the set value. To achieve accelerated response, it is equipped with a sliding spool, and the flow control valve in the spool keeps the control oil flow constant.

Parker派克DSA-P07系列比例溢流阀

Parker DSA-P07 series proportional relief valve

The Parker DSA-P07 series proportional relief valve is controlled by an external electronic module. This allows for seamless selection of the required response pressure value for the overflow function. Corresponding regulating nozzles are installed in the pilot valve for each pressure level. The direct acting valve NG06 can also be used as a pilot valve for the DSA series.

Parker派克VB*L系列直动式比例溢流阀

Parker VB * L series direct acting proportional relief valve

The Parker VB * L series direct acting proportional relief valve can continuously adjust the pressure from minimum to rated pressure. Typical applications include hydraulic control devices that require only a small amount of oil flow (such as tool adjustment), or pilot valves used as hydraulic control mechanisms for variable displacement pumps. The electrical control of the valve adopts plug-in amplifier VS110 or digital amplifier VRD350 or VRD355, or PCD module. It can also be used in closed-loop pressure regulation circuits.

Parker派克RE*W系列直动式比例溢流阀

Parker RE * W series direct acting proportional relief valve

The Parker RE * W series direct acting proportional relief valve allows for continuous adjustment of the valve's minimum pressure to the rated pressure. Usually only used for regulating hydraulic equipment that requires very small flow rates, or as a pilot valve for regulating variable displacement pumps. The electric proportional control of the valve is carried out using the PCD00A-400 digital amplifier board and can be used for closed-loop pressure control.

Parker派克VBY*L/VMY*L系列先导式比例压力阀

Parker VBY * L/VMY * L series pilot operated proportional pressure valve

Parker VBY * L/VMY * L series pilot operated proportional pressure valves are typically used in clamping pressure systems, testing and inspection devices, or weight balancing systems. It can also be used in closed-loop pressure control circuits. The structure of VBY * L: The relief valve consists of a main stage with a valve core and a pilot stage. There are control oil nozzles and damping holes on the pilot stage. The highest required system pressure can be infinitely adjusted on the electronic amplifier board according to the set value. The electromagnet converts the current into a force acting on the pilot stage valve cone. The structure of VMY * L: The pressure reducing valve consists of a main stage with a valve core and a pilot stage. There is a flow limiting valve on the pilot stage. The control oil is taken from the interior and comes from the P-channel (primary control) of the valve body. Control the internal reflux of oil.

Parker派克VMY*L*N系列先导式比例压力阀

Parker VMY * L * N series pilot operated proportional pressure valve

Parker VMY * L * N series pilot operated proportional pressure valves can continuously regulate pressure, reducing pressure from 0 to rated pressure. Typical applications include clamping pressure systems, testing and inspection devices, or weight balancing systems. The electrical control of the valve adopts digital amplifier VRD350 or VRD355, or plug amplifier VS110 or PCD module. It can also be used in closed pressure regulation circuits. The valve stands out for its excellent voltage stabilization performance.

Parker派克RE*W系列先导式比例溢流阀

Parker RE * W series pilot operated proportional relief valve

The Parker RE * W series pilot operated proportional relief valve consists of a pilot stage operated by a proportional solenoid and a DIN standard NG25 plug-in valve as the main stage. By relying on the given signal of electricity, the pressure can be infinitely adjusted. Provide the given value to the control system through an external electronic module. Use corresponding adjustment nozzles on the pilot valve for different pressure levels.

Parker派克RE*T系列比例溢流阀

Parker RE * T series proportional relief valve

The Parker RE * T series proportional relief valve consists of a pilot stage operated by a proportional solenoid with integrated electronic control components and a DIN standard NG25 plug-in valve as the main stage. The power supply voltage and the given value signal (current or voltage value) can be transmitted through a seven pin plug. The input command can be between 0 and 10V or 0 and 20mA, please refer to the order number. The ramp time for increasing and decreasing pressure can be adjusted on two potentiometers without interfering with each other. When the entire useful signal range is not changed, the maximum and minimum potentials can determine the pressure range of the hydraulic system. Use corresponding adjustment nozzles on the pilot valve for different pressure levels.

Parker派克DWE/DWU系列比例减压阀

Parker DWE/DWU series proportional pressure reducing valve

The Parker DWE/DWU series proportional pressure reducing valve is basically the same as the DWL/DWK series, except that it is adjusted using a proportional solenoid. Controlled through external electronic modules.

Parker派克PE/PC系列先导式比例减压阀

Parker PE/PC series pilot operated proportional pressure reducing valve

The Parker PE/PC series pilot operated proportional pressure reducing valve has a proportional solenoid controlled pilot stage and a slide valve main stage, and its hydraulic function principle is the same as the DWL/DWK series. The power supply voltage and input command signal are connected through a single 7-pin electrical plug. The input command signal can be within the range of 0-10V or 0-20mA, and can be selected in the order code. The increase and decrease of pressure ramp time can be individually set on two potentiometers. The minimum and maximum potentiometers can be used to set the minimum and maximum pressures. These can calibrate the set pressure range corresponding to the entire range of the command input signal.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!