Detection Principle
The YC-109S economical ammonia nitrogen rapid analyzer is developed and designed according to HJ535-20009 "Determination of Ammonia Nitrogen in Water Quality - Nessler's Reagent spectrophotometric method". Ammonia nitrogen in the form of free ammonia or ammonium ions reacts with Nessler's reagent to form a light yellow brown complex. The absorbance of the complex is proportional to the ammonia nitrogen content, and colorimetric method is used. After collecting water samples, users can add matching reagents to directly measure the ammonia nitrogen content in the water sample on the instrument.
Technical Parameter
Testing items |
Ammonia nitrogen |
Testing standards |
HJ535-20009Water quality - Determination of ammonia nitrogen - Nessler's reagent spectrophotometric method |
Range of measurement |
0-50mg/L |
limit of detection |
0.001mg/L |
Measurement Error |
≤± 5% |
repeatability |
≤±5% |
Optical stability |
≤±0.001A/20minute |
Colorimetric method |
⌀16mmColorimetric tube |
data processing |
1800Records80Curve |
Operation interface |
Chinese |
display |
5cunLCD |
Power supply mode |
AC220V±10%/50Hz |
power |
3W |
work environment |
5-45℃ ≤85%No condensation |
Host size |
310mm*240*155 |
Instrument weight |
host<2kg |
Instrument characteristics
1. Based on the national standard HJ535-20009 "Nessler's reagent spectrophotometric method", the research and design ensure accurate and effective measurement.
2. Adopting imported high brightness and long-life cold light source, with excellent optical performance and a light source lifespan of 100000 hours.
3. Large LCD screen with full Chinese display, direct data reading, simple and time-saving operation.
4. Integrated digestion and colorimetric analysis, no need to replace the tube, simple and fast measurement, and no safety hazards.
5. It can save 80 standard curves and 1800 measured values (date, time, parameters, test data).
6. Memory standard working curve, users can also calibrate the curve as needed.
7. One click factory reset, which can quickly recover in case of curve loss caused by misoperation.
8. It has data storage function and power-off protection function, making it convenient to query historical data and prevent data loss.
Standard configuration
Serial Number |
name call |
quantity |
Serial Number |
name call |
quantity |
1 |
Rapid measurement of economical ammonia nitrogenFixed instrument host |
1tower |
6 |
Simplified operation flowchart |
1share |
2 |
⌀16mmColorimetric tube |
10branch |
7 |
operation instructions |
1share |
3 |
Ammonia nitrogen determination reagent |
1cover |
8 |
Color comparison rack |
1individual |
4 |
Color tube cleaning cloth |
1piece |
9 |
certificate of conformity |
1share |
5 |
warranty card |
1share |
10 |
Power Cables |
1strip |