Shanghai Zhongyou Industrial Co., Ltd
Home>Products>Electrode humidifier
Electrode humidifier
Shanghai Zhongyou Industrial Co., Ltd. is a professional manufacturer of air treatment products such as dehumidification, humidification, and refriger
Product details

1、 Product Introduction and Working Principle
There is generally a certain conductivity in tap water. By directly inserting the electrode into tap water and connecting it to an AC power source, due to the conductivity of water, current will pass through the water between the electrodes, and all the electrical energy transmitted to the water will be converted into heat energy, causing the water to heat up and produce steam.
SDJThe electrode humidifier adopts a more stable mesh electrode sheet, and the current size is related to the power supply voltage, the area of the electrode immersed in water, and the conductivity. The amount of steam generated by the humidifier is affected by the power or current strength, and the current control can be adjusted by changing the area of the electrode immersed in water. Maintaining the conductivity of water within a certain range can achieve good system continuous control.
The steam pressure generated by the electrode humidifier is low, and the steam does not contain minerals, bacteria, or white powder.

4、 Scope of application
SDJThe electrode humidifier is suitable for air conditioning matching, electronic factories, pharmaceutical factories, and hospital clean humidification.

5、 Characteristics
The steam humidifier has a compact installation, saves floor space, provides high-quality steam supply, high equipment efficiency, and competitive price.
Streamlined exterior design, focusing on the best combination of functionality and economy, with a user-friendly interface.
Disposable and washable humidification buckets can be freely selected for easy use and replacement.
Switching control and analog control are optional, (accepted)0-10Signal), steam output is4-90kg/h, optional.

6、 Interpretation of Humidifier Number

SDJ—01/02A/B
01:Suitable for combination air conditioning units, fresh air units, and air ducts;02Suitable for direct indoor humidification
A: Switching quantity adjustmentBContinuous adjustment
7SDJTechnical Parameters and Selection Table of Type Electrode Humidifier
TABLE I

Model

Humidification amount

Power

Power supply

Quantity of humidification buckets

External dimensionsmm

SDJ-4

4 Kg/h

3 .0 Kw

~220V 50Hz

1individual

215×465×485

SDJ-8

8 Kg/h

5.25 Kw

~380V 50Hz

1individual

215×465×485

SDJ-10

10 Kg/h

7.5 Kw

~380V 50Hz

1individual

270×550×625

SDJ-12

12 Kg/h

9.75 Kw

~380V 50Hz

1individual

270×550×625

SDJ-15

15 Kg/h

11.25 Kw

~380V 50Hz

1individual

270×550×625

SDJ-20

20 Kg/h

15 Kw

~380V 50Hz

1individual

270×550×625

SDJ-23

23 Kg/h

17.25 Kw

~380V 50Hz

1individual

270×550×625

SDJ-30

30 Kg/h

22.5 Kw

~380V 50Hz

1individual

370×580×700

SDJ-36

36 Kg/h

27 Kw

~380V 50Hz

2individual

370×580×700

SDJ-42

42 Kg/h

31.5 Kw

~380V 50Hz

2individual

370×580×700

SDJ-45

45 Kg/h

34.2 Kw

~380V 50Hz

2individual

370×580×700

SDJ-60

60 Kg/h

45 Kw

~380V 50Hz

2individual

370×580×700

SDJ-80

80 Kg/h

60 Kw

~380V 50Hz

3individual

270×1070×700

SDJ-90

90 Kg/h

67.5Kw

~380V 50Hz

3individual

270×1070×700

SDJ-120

120 Kg/h

90Kw

~380V 50Hz

3individual

270×1070×700

Stainless steel nozzle selection table (Table 2)

Model

Nozzle diameter(mm

Quantity required for nozzle

Spray nozzle length(mm

SDJ4~SDJ15

Φ22

1individual

290

SDJ20~SDJ30

Φ22

1individual

590

SDJ36~SDJ60

Φ34

2individual

590

SDJ80~SDJ120

Φ34

2individual

800

Note: The diameter of the drainage outlet isΦ20

8SDJInstallation of Type Electrode Humidifier
   When choosing the location for installing a steam humidifier, it is important to pay attention to the following points:
ambient temperature5-40
Relative humidity below80%RH
When connecting the steam distribution pipe to the steam humidifier, the shortest length of steam outlet hose and condensate return hose should be used as much as possible.
The hose should avoid sagging and knotting, and should also5-10%The slope
Humidifiers must be installed vertically in order to function properly.

9、 Cleaning and maintenance of steam drum
When the humidification amount of the electrode humidifier does not reach the predetermined humidification amount, if other components are working normally, it means that the steam cylinder needs to be cleaned. Here are the cleaning steps and precautions:
Remove the shell, remove the connectors, and take off the upper half of the steam cylinder.
Remove all scale and sludge from the steam cylinder.
Tap the heating electrode to remove the scale on the electrode, allowing a small portion to remain.
Check the upper water level detector of the steam cylinder and flush to remove any impurities attached to it.
Rinse the filter in the steam cylinder.

be careful:
Do not use acidic or chemical detergents during cleaning.

If the humidity is insufficient due to insufficient conductivity of water, a small amount of salt can be added to the cylinder.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!