Yongjia Quanda Pump and Valve Manufacturing Co., Ltd
Home>Products>Engineering plastic centrifugal pump FS type
Engineering plastic centrifugal pump FS type
Engineering plastic centrifugal pump FS type
Product details

FSType engineering plastic centrifugal pumpAs a horizontal structure, the pump body is made of engineering plastic ABS and reinforced polypropylene PRR molded in one go, which has the advantages of small volume, light weight, compact structure, and good sealing performance. Mainly used for transporting corrosive liquids such as acids, alkalis, salts, etc. that do not contain suspended solids and particles. The pump body material is non-toxic. It can be widely used in industries such as chemical, pharmaceutical, recycled water, electroplating, environmental protection, electronics, and food.

FS type engineering plastic centrifugal pumpMainly used for transporting corrosive liquids such as acids, alkalis, salts, etc. that do not contain suspended solids and particles. The pump body material is non-toxic. It can be widely used in industries such as chemical, pharmaceutical, recycled water, electroplating, environmental protection, electronics, and food.

FS型工程塑料化工泵

Technical Parameter

model
Caliber (mm)
internet traffic
m3/h
lift
m
Suction distance
m
rotational speed
r/min
voltage
V
power
kw
Import
Export
FS20-15-100(105)
20
15
3
7
4
2900
380
0.75
FS32-25-105(104)
32
25
4
7
6.5
2900
220
0.55
FS32-25-105(103)
32
25
6.3
8
6.5
2900
380
0.75
FS40-32-125(102)
40
32
12.5
20
6.5
2900
380
1.5
FS65-50-150(101)
65
50
25
25
6
2900
380
4

1. Plastic pumps should be installed horizontally, and the pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must be facing upwards.

2. Add water to the pump body before use. When the suction liquid level is higher than the axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.

3. Before starting the motor, check whether its rotation direction is consistent with the pump direction mark.

4. The conveyed medium and temperature should be within the allowable range of the pump material (see attached table). Centrifugal pumps should be used at temperatures FP ≤ 80 ℃ and FS ≤ 60 ℃. The temperature rise of the motor should not exceed 80 ℃, and the ambient temperature should be less than 40 ℃.

5. No no-load operation is allowed.

Appendix: Corrosion Resistance of Plastic Pump Materials

medium

concentration

CFR-PP

medium

concentration

ABS

25℃

65℃

90℃

20℃

60℃

80℃

Sulfuric acid H2SO4

98%

Sulfuric acid H2SO4

<30%

×

70%

30-70%

×

1-50%

>75%

×

×

Nitric acid HNO3

concentrated

Nitric acid HNO3

10%

20%

20%

10%

25-35%

>50%

×

×

Hydrochloric acid HCL

0-30%

×

Hydrochloric acid HCL

<30%

×

hydrofluoric acid

×

hydrofluoric acid

<10%

×

40-48%

×

acetic acid

1-50%

acetic acid

<20%

phosphoric acid

Various concentrations

>30%

×

×

sodium hydroxide

sodium hydroxide

sodium chloride

sodium chloride

×

ferric chloride

ethanol

ethanol

bleaching solution

bleaching solution

×

Explanation: √ - Good;○ - Available but corroded; X - Unavailable, severely corroded

Pump malfunction forms and troubleshooting methods

failure mode

cause

Troubleshooting

The pump cannot produce liquid

  1. Pump reversal
  2. Leakage in the inlet pipeline
  3. There is too little liquid stored in the pump chamber
  4. The suction distance is too high
  5. Bottom valve leakage
  6. Impeller obstructed and unable to rotate
  1. Change the motor wiring
  2. Eliminate air leakage
  3. Increase the storage capacity
  4. Lower the installation position of the pump
  5. Clean the bottom valve
  6. Clean the pump casing and impeller

Insufficient traffic

  1. The suction pipe diameter is too small
  2. Impeller channel blockage
  3. Head too high
  4. There is air leakage in the suction pipeline
  5. Damaged impeller
  1. Replace the liquid inlet
  2. Clean the impeller
  3. Turn up the outlet valve
  4. Eliminate air leakage
  5. Replace the impeller

Low head

  1. Too much traffic
  2. The speed is too low
  1. Turn down the outlet valve
  2. Restore rated speed

Low noise level

  1. There are debris inside the pump
  2. Friction between rotating parts and fixed parts
  3. Severe wear of the shaft
  1. Check and clean
  2. GAP
  3. Replace the pump shaft

Leakage of liquid

  1. Loose fixing screws of pump casing
  2. Severe wear of mechanical seal
  1. tighten the screws
  2. Replace the mechanical seal

Please provide as much as possible for ordering:1. Model2. Caliber3. Head (m)4. Traffic5. Motor power (KW)6. Speed (R/min)7. Voltage (V)8. Does the material come with accessories

Welcome to visit our website at Yongjia Quanda【www.quandabf.com】If you have any questions Our company specializes in productionCentrifugal pumps, sewage pumps and other products. You can call us at, and we will do our best to provide you with high-quality service.

Related products:

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!