Our company hasLarge quantity of spot goodsSecond hand chromatographic equipment;(List of main products)
1Gas chromatograph:Agilent5890 gas chromatograph, 6890 6890N gas chromatograph、7890A gas chromatograph;; Shimadzu GC2010 gas chromatograph;
2Liquid chromatograph: Agilent1100 liquid chromatography, 1200 liquid chromatography, 1260 liquid chromatography;; Shimadzu 10A liquid phase, Shimadzu 20A liquid phase;; Waters 1525 liquid chromatography and 2695 liquid chromatography;;
3Gas chromatography-mass spectrometry: Agilent6890N-5973N gas chromatography-mass spectrometry, 7890A-5975 gas chromatography-mass spectrometry;; Shimadzu QP2010, QP2010Plus, QP2010Utria gas chromatography-mass spectrometry;;
4Liquid chromatography-mass spectrometry (LC-MS) instrument: AgilentG6410B liquid quality;; AB: Liquid chromatography-mass spectrometry instruments such as API3200/API4000;;
5Headspace sampler: Agilent7694, 7694E G1888 、7697A;; Shimadzu HS-10 HS-20;; Italian Danny HSS-86.50;; PE HS-40 headspace sampler
6Temage detachment Max Blows and Captures Yintai Suma Tank System
JunqiinstrumentCurrently underwayInstrument leasing businessVarious chromatographic equipment available for rent and sale;; Inquire more about Junqi Instrument Hotline18017027751 www.sh-junqi17.com
Junqi Instrument Equipment (Shanghai) Co., Ltd
Sales hotline: 18017027751
Technical Department: 13761342293
1The host comes with a two-way valve control system, which facilitates online automatic sampling.
2. The inter column compensation circuit provides electronic compensation for baseline drift during program temperature rise operation, reducing the impact of the second The complexity brought by root columns, detectors, and auxiliary flow systems.
3. The signals from the detector, heater values, furnace temperature, flow sensor readings, or stored column compensation baseline signals can all be assigned to a simulated output channel.
4. Self testing and fault diagnosis, experimental data stored for power-off protection, stopwatch and running timer, keyboard locking function.
7. Can install two flow sensing channels and two single column compensation channels.
Heating furnace system
Temperature range: ambient temperature+5 ℃~400 ℃, third-order programmed heating, heating rate 0-50 ℃/min; increase
1Hydrogen flame ionization detector (FID):
Sensitivity: Type A Mt ≤ 5 ×10-11g/s(N-Hexadecane)
Baseline noise: ≤ 6×10-12A/H
Linear range: ≥105
Stable time:< 0.5h
Stable time: Type A<1.5h Cut off gas protection