Special Offer Fluke FLUKE Ti50 Thermal Imager
¥ 185000.0
Technical specifications
Imaging performance thermal imaging
Field of View (FOV) * 23 º horizontal x 17 º vertical
Spatial resolution (IFOV) * 1.30 mrad
*Small focusing distance * 0.15 m
Thermal sensitivity (NETD) Ti55: ≤ 0.05 ° C at 30 ° C
Ti50: ≤ 0.07 °C at 30 °C
Detector data acquisition/image frequency 60 Hz/60 Hz
Focus on SmartFocus; Only one finger is needed for continuous focusing operation
IR digital zoom Ti55: 2x, 4x, 8x
Ti50: 2x
Detector type 320 x 240 focal plane array, vanadium oxide (VOx) uncooled microcalorimeter with 25 micron pitch
Spectral band 8 µ m to 14 µ m
Automatic full-time enhancement of digital image enhancement
Visible light (* * for Fusion models)
The operation mode of the camera itself is full heat/full visible light or mixed heat visible light image picture-in-picture
Visible light camera 1280 x 1024 pixels, full-color
Visible light digital zoom Ti55: 2x, 4x, 8x
Ti50: 2x
Temperature measurement calibration temperature range Ti55: -20 ° C to 600 ° C (-4 to 1112 ° F) in 3 ranges
Ti50: -20 ˚C to 350 ˚C (-4 to 662 ºF) in 2 ranges
量程 1 Ti55: -20 ˚C to 100 ˚C (-4 to 212 ºF)
Ti50: -20 ˚C to 100 ˚C (-4 to 212 ºF)
量程 2 Ti55: -20 ˚C to 350 ˚C (-4 to 662 ºF)
Ti50: -20 ˚C to 350 ˚C (-4 to 662 ºF)
量程 3 Ti55: 250 ˚C to 600 ˚C (482 to 1112 º