The YF-8801-PM series dust concentration detector is widely used in various industrial applications, including steelmaking, power generation, petroleum, chemical, pharmaceutical, building materials processing, coal mining and mining, cement manufacturing and packaging industries. Typical applications include detecting damaged filter bags in bag filters, recovering powdered materials, monitoring the total amount of product transportation, or monitoring the concentration of smoke and dust emissions from boilers of various sizes and fuels.
ØProduct Introduction
The YF-8801-PM series dust concentration detector has four major features:
1. Adopting the most advanced practical technology - patented improved AC coupling technology, it has high sensitivity and good linearity for dust detection. Dust contamination of the probe does not affect the measurement sensitivity and is maintenance free and cleaning free.
2. Standard two-line system4-20mACurrent output, strong anti-interference ability, easy long-distance signal transmission, no special requirements for signal transmission wires, linear relationship between output current and dust concentration, convenient for subsequent usePLCData processing.
3. The installation and use are completely consistent with the two-wire pressure transmitter, and on-site engineering and technical personnel can use it correctly without any special training. The installation is convenient and the operation is reliable.
4. The junction box is equipped with an integrated transmitter output4-20mAElectrical isolation is achieved between the current and dust sensing probes to ensure safe signal transmission.
Øtechnical specifications
operating ambient temperature |
-20℃~60℃ (electronic components) |
Operating environment humidity |
No condensation90% |
Operating environment vibration |
Maximum continuous oscillation, any direction, any frequency: root mean square value2g (20m/s2) |
Operating environment electromagnetic field |
exist50 Maximum value at Hertz=60A/m (Equivalent to one1 Mi x1 Inside the square electromagnetic coil, there is50ATThe magnetic field) |
Protection of operating environment |
Protection level:IP66/NEMA4Aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe |
Pipeline gas pressure |
-0.1 –1MPa |
Pipeline gas flow rate |
1m/s~30m/s |
Pipeline gas temperature |
0℃~250℃(260℃-800C can be customized) |
Pipe OD |
0.1Mi~4 rice |
Probe structure |
The standard probe is φ16mm, Length100mm-1000mmProbe material: Rare earth amorphous alloy, |
Dust particle size range |
nominal0.1μM~200 μMIt can still receive signals outside the nominal range, but the signal characteristics are slightly different. |
powder material |
Including: dust, coal powder, flour, dust, smoke, graphite, manganese dioxide, quicklime and other various particulate matter |
zero drift |
(time)Below range every year1%. |
zero drift |
(temperature)Within the specified temperature range, below the measuring range1%. |
Full-scale drift |
(time)Below range every year1% |
Full-scale drift |
(temperature)Within the specified temperature range, below the measuring range1%. |
Line stability |
All components of the system are made of high stability electronic assemblies. |
Noise resistance |
all50 perhaps60 Hertz audio and harmonics are all filtered out before the signal is received |
measuring range |
0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m³ |
Transmitter output mode |
two-wire system4 –20mA(Built in isolator, explosion-proof and anti-interference) |
Transmitter power supply |
24V(15V~32VAvailable within the scope) |
measurement accuracy |
±5% |
Probe length selection |