brand | NGP/High Quality Technology | Origin category | domestic |
---|
Product Features:
① Imported high-performance sensors with excellent anti-interference performance
② Adopting advanced microprocessor technology, it has fast response speed, high measurement accuracy, good stability and repeatability
③ The detection site has on-site sound and light alarm function, and the gas concentration exceeds the standard and immediately alarms, which is a safety guarantee for dangerous on-site operations
④ On site backlit large screen with multiple parametersLCDDisplay, visually show gas concentration, type, unit, working status, etc
⑤ Independent chamber, no need for on-site calibration when replacing sensors, automatic identification of key sensor parameters
⑥ Full range temperature digital automatic tracking compensation ensures measurement accuracy
⑦ Full software automatic calibration function, this machine is equipped with standard four buttons to achieve single person single point on-site maintenance of technical parameters
Fixed hydrogen cyanide detector with sound, light and alarm integrated machine
Gas detection: Hydrogen cyanide
Measurement range:010. 20, 50100ppm、 500ppm1000ppm、 five thousandppm
resolution :0.01ppm0.1ppm
Detection principle: electrochemistry
Detection methods: fixed, online detection, diffusion measurement、Pump suctionmeasureoptional
Installation methods: wall mounted, pipe mounted, and flow-through options are available
Accuracy: ± 3% FS
Display mode: LCD display (optional)
Response time:≤30second
Recovery time:≤60second
Explosion proof mark:ExiaⅡCT6 Ga
AApplicable to0 District1District2 District, containingIIA~IICClass,T1~T6Explosive gas mixture sites;
BThe product has passed the inspection of the National Explosion proof Electrical Product Quality Inspection Center and obtained the Explosion proof Certificate of Conformity;
Explosion proof connection thread:3/4'NPT
simulateSignal output:Three (four)Wire system 4-20mALinear output (optional two-wire system)
Digital signal output: bus systemRS485 digital signal output,Combined with RS232 adapter card, data can be stored on the computer(Optional)
Maximum transmission distance:1100Rice(Rvv0.75Square millimeter shielded cable),Can support wireless transmission without wiring
Working temperature:- 20℃~+50℃
Relative humidity: 10% to 95% RH (non condensing)
Power supply: 24VDC ± 12VDC
Maximum power consumption: 2.5W
Weight: Approximately 1.5Kg
Fixed hydrogen cyanide detector with sound, light and alarm integrated machine