Shenzhen Xinma Technology Co., Ltd
Home>Products>Fluke Norma 4000 Power Analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Room 1008, Building C, Xinghe Legend Phase III Commercial Building, Lvjing Road, Minzhi Street, Longhua District, Shenzhen
Contact Now
Fluke Norma 4000 Power Analyzer
Fluke Norma 4000 Power Analyzer
Product details

Fluke Norma 4000 功率分析仪/功率计

FlukeFluke Norma 4000 power detection analyzer/power meterVery suitable for on-site testing, providing a convenient and intuitive operating method with unparalleled cost-effectiveness. Its features include: 1-3 power modules, 5.7 "/144 mm color display screen, harmonic analysis, FFT analysis, oscilloscope mode, vector diagram, recorder function, Fluke NormaView PC software, and 4 MB RAM data storage.


Fluke Norma 4000 Power Analyzerfunction characteristics

User selectable average time -15 ms to 3600 s, suitable for dynamic measurement

The simple user interface of the power detection analyzer/power meter ensures easy and intuitive operation

The standard configuration allows users to accurately specify the corresponding functions that are suitable for their specific applications

Simultaneously collect all phases in parallel and accurately display dynamic events on all phases at a specific time point

All inputs of the power detector/power meter are electrically isolated to avoid short circuits in various applications

Up to 40 times of voltage, circuit, and power harmonics

FFT analysis, vector graphics, recorder functions, and digital oscilloscope (DSO) mode

Power detection analyzer/power meter 4 MB onboard memory (expandable up to 128 MB) for storing measurement values

Quick and convenient connection to PC - RS232 and USB are standard. Optional IEEE488, Ethernet, or USB2.0

The PI1 process interface can measure torque and speed through external sensors. Containing 4 analog outputs, it can be conveniently used for motor and drive applications.

341 kHz or 1 MHz sampling rate for detailed signal analysis

● DC~3 MHz/10 MHz bandwidth, reliable measurement accuracy.

● Includes Fluke NormaView PC software, which can be used to download data, analyze, and write reports.


Fluke Norma 4000 Power Analyzerapplication

Electric motor and inverter drive system power detection analysis - The power meter can accurately measure the switching losses caused by the inverter through detailed spectrum analysis and dynamic torque calculation, and can comprehensively evaluate torque transients and harmonics at high frequencies.

Power detection analysis of inverter drive system - The power meter can simultaneously measure all electrical and mechanical power parameters within the same event window, allowing users to observe the impact of one component on another or its impact on the entire system.

Lighting system power detection analysis - The power meter has a unique bandwidth of up to 10 MHz and a high sampling rate of up to 1 MHz, which can analyze the rectifier output signal in detail. The unique splitter technology can perform power detection at very high frequencies. Meanwhile, the function of measuring input and output power provides the ability to calculate rectifier losses.

Transformer power detection analysis - The power meter synchronously measures 6-phase power, even at very small power factors, and can calculate the efficiency and loss of high-precision high-power transformers. It can also synchronously measure the resistance of multiphase transformer coils.

Automotive power detection analysis - The power meter synchronously measures electrical input and mechanical output, providing data on the efficiency and losses of individual components and the entire drive system.

General technical indicators
Number of modules Fluke Norma 4000:
1 ~ 3 Fluke Norma 5000:
3. 4 or 6 Weight of power detector/power meter
Fluke Norma 4000: About 5 kg (11 lb.)
Fluke Norma 5000: About 7 kg (15 lb.)
Size of power detector/power meter Fluke Norma 4000:
150 mm x 237 mm x 315 mm (5.9 in x 9.3 in x 12.4 in)
Fluke Norma 5000: 150 mm x 447 mm x 315 mm
(5.9 in x 17.6 in x 12.4 in) Built-in printer
Fluke Norma 4000: not have
Fluke Norma 5000: Yes (optional)
display Color, 5.7 "/144 mm -320 x 240 pixels
User selectable backlight illumination and contrast bandwidth
DC~3 MHz or DC~10 MHz, depending on the input module Basic accuracy
0.2%, 0.1%, or 0.03%, depending on the input module Sampling rate of power detector/power meter
0.33 MHz or 1 MHz, depending on the input module Voltage input range of power meter
0.3 V ~ 1000 V Current input range (direct input, without using a shunt)




0.03 mA to 20 A, depending on the input module
Configure Memory 4 MB
Set storage 0.5 MB
Fast Fourier Transform (FFT) Up to the 40th harmonic
RS-232/USB interface standard configuration
PI1 processing interface (8 analog/pulse inputs and 4 mode outputs) option
IEEE 488.2/GPIB interface (1 MBit/s Ethernet/10 MBit/s or 100 MBit/s) option
Fluke NormaView PC software (for downloading, analyzing, and writing reports on user data) standard configuration


basic function
Fast Fourier Transform (FFT) Calculate harmonics and identify them graphically. Up to 3 harmonic spectra can be displayed simultaneously.
Tested values: U, I, and P for each phase. Order: 1st to 40th harmonic, maximum half sampling frequency.
Digital Oscilloscope (DSO) Simultaneously display up to 3 measurement values (sampled values). Quickly view waveforms and distortions.
Integral function (energy) Simultaneously display up to 6 configurable numerical values. Start/stop conditions and positive/negative options.
vector graphic It can display the fundamental vector diagram of up to 6 signals. It can facilitate the correct connection of testing instruments and quickly view the phase angle of each signal.
Power detection recorder Display the average value over a certain period of time for trend analysis.
RAM data storage Store sampled values and average values; Start/stop condition settings.
Approximately 4MB can be used to store measurement values. The memory can be expanded to 128 MB configuration


Set the analyzer to measure and display data in the desired format.
environmental condition


Power detector/power meter operating temperature range
5 °C ~ 35 °C (41 °F ~ 95 °F)
Storage temperature range -20 °C ~ 50 °C (-4 °F ~ 122 °F)


Housing material
The Fluke Norma power analyzer has a very compact structure and uses a solid metal casing to meet demanding EMC requirements. Climate Type
KYG DIN 40040, Maximum relative humidity of 85%, no condensation. power supply
85-264 V AC, 50-60 Hz, DC 100-260 V. 40 VA European style plug with switch. We can provide current terminals of the same model. Measuring input
Safety jack, 4 mm, 2 inputs per channel. The external splitter is connected through a BNC socket. option


Thin film keyboard with cursor keys - function keys and direct function keys.
connect

Rear panel of three-phase analyzer

Configure Memory

Up to 15 sets of user configurations can be saved to permanent memory and subsequently recalled. Unsaved modifications will be lost after closing the instrument.
interface RS232 interface, capable of upgrading firmware and exchanging data with PC. A printer can be connected through an external converter.
option IEEE 488.2 / 1 MBit/s
Ethernet / 10 MBit/s or 100 Mbit/s Standards and safety
Electrical safety EN 61010-1 / 2nd Edition 1000 V CAT II (600 V CAT III) ,