FluorCam portable photosynthetic chlorophyll fluorescence imaging system
FluorCam portable photosynthetic chlorophyll fluorescence imaging system
Product details

FluorCamPortable photosynthetic chlorophyll fluorescence imaging system

The photosynthetic parameters such as photosynthetic rate, transpiration rate, and stomatal conductance of plants can comprehensively measure the intensity and ability of plant photosynthesis; Chlorophyll fluorescence not only reflects the primary reaction processes of photosynthesis, such as light energy absorption, excitation energy transfer, and photochemical reactions, but also relates to electron transfer, proton gradient establishment, ATP synthesis, and CO2Fixed and related processes. The combined measurement of both is indispensable in the study of plant photosynthetic physiology. The FluorCam portable photosynthetic chlorophyll fluorescence imaging system can be combined with the internationally renowned photosynthetic instrument LCpro to measure both photosynthesis and plant fluorescence. It can also work independently in the laboratory or field.

image.pngFunctional features:

·Can be installed on LCproTSimultaneous measurement of fluorescence and photosynthesis can be performed on the leaf chamber of the photosynthesis analyzer, and it can also work independently

·Strong portability, suitable for both laboratory and field use

·You can edit the measurement experiment protocol by yourself

·It can perform both continuous photochemical imaging measurement and PAM imaging measurement

·Optional handheld chlorophyll rapid fluorescence kinetics measurement module

·OptionalFlat panel industrial control computer

Technical parameters:

·Measurement parameters: Fo, Fo’, Fs, Fm, Fm’, Fp, FtDn, FtLn, Fv, Fv'/ Fm',Fv/ Fm ,Fv',Ft,ΦPSII, NPQ_Dn, NPQ_Ln, Qp_Dn, Qp_Ln, qN, qP,QY, QY_Ln, Rfd, ETR Waiting for over 50 chlorophyll fluorescence parameters, each parameter can display a 2D fluorescence color image

·Equipped with a complete automatic measurement program (protocol), the automatic measurement program can be freely edited

a)Fv/FmMeasurement parameters include Fo, Fm, Fv, QY, etc

b)KautskyInduction effect: Fluorescence parameters such as Fo, Fp, Fv, Ft_Lss, QY, Rfd, etc

c)Fluorescence quenching analysis: Fo,Fm,Fp,Fs,Fv,QY,ΦII, More than 50 parameters including NPQ, Qp, Rfd, qL, etc

d) image.pngLight response curve LC: Fluorescence parameters such as Fo, Fm, QY, QYLn, ETR, etc

·High sensitivity TOMI-1 CCD sensor:

a)Image resolution: 720 × 560 pixels

b)Time resolution: 50 frames per second

c)A/DConversion resolution: 12 bits (4096 grayscale levels)

d)Pixel size: 8.6 µ m × 8.3 µ m

e)Communication mode: Gigabit Ethernet

·4Block ultra bright LED light source board, with a uniform illumination area of 2.5×2.5 cm

·Measurement light: 620nm red light, duration 10 µ s100µsadjustable

·Photochemical light, saturated light flicker: white lightChoose one of blue light, red light, or optional red light+blue light,Standard white light

·Far red light: 735nm, used for measurementFo’, 4 high-energy LEDs

·FluorCamChlorophyll fluorescence imaging analysis software features: Live (real-time testing), Protocols (customized experimental program selection), Pre processing (imaging preprocessing), Result (imaging analysis results) and other functional menus

·Customized experimental program protocols for customers: can set time (such as measurement light duration, photochemical light duration, measurement time, etc.), light intensity (such as photochemical light intensity of different qualities, saturation light flash intensity, modulated measurement light, etc.), with dedicated experimental program language and scripts. Users can also freely create new experimental programs using the wizard program template in the Protocol menu

·Automatic measurement and analysis function: An experimental program (Protocol) can be set to automatically perform unmanned cyclic imaging measurements. The number of repetitions and interval time can be customized by the customer, and the imaging measurement data will be automatically stored in the computer according to the time and date (with a timestamp)

·Snapshot mode: Through snapshot imaging mode, the light intensity, shutter time, and sensitivity can be freely adjusted to obtain clear and prominent steady-state and instantaneous fluorescence images of plant samples

·Imaging preprocessing: The program software can automatically identify multiple plant samples or regions, or manually select regions of interest (ROI). The shape of manual selection can be square, circular, any polygon, or sector. The software can automatically measure and analyze the fluorescence kinetics curves and corresponding parameters of each sample and selected area, with no limit on the number of samples or areas (>1000)

·Data analysis mode: It has "signal calculation and re averaging" mode (arithmetic mean) and "signal average and re calculation" mode. In high signal-to-noise ratio situations, the "signal calculation and re averaging" mode is selected, and in low signal-to-noise ratio situations, the "signal average and re calculation" mode is selected to filter out errors caused by noise

·Tablet type industrial control computer (optional): used for long-term field measurement

·Handheld chlorophyll rapid fluorescence kinetics measurement module(Optional): Can measure OJIP curve and more than 20 related parameters

·CCDDetector bandwidth: 400-1000 nm

·Spectral response: The quantum efficiency is highest at 540nm (70%), and decreases by 50% at 400nm and 650nm

·Read out noise: below 12eRMS, typical 10e

·Full trap capacity: greater than 70000 e (unbound)

·Bios: Firmware upgradable

·Weight: 1.8 kg

Origin: Europe