Product Name: Food Vacuum Packaging Machine (PLC Computer Programming)
Runkang brand 1100 single sealed continuous vacuum packaging machine

Product Introduction:
This product is independently developed by the company, with advanced functions and high configuration
Low failure rate, achieving continuous operation for 10-24 hours.
Functional advantages:

·Waterproof design of electrical box
·PLC programming touch computer board
·Schneider, Omron, Chint brand electrical appliances

·Studio and countertop made of 8mm thick 304 steel plate
·Sealing pre pressure, bag mouth flattening during heating sealing
·Easy to replace water-cooled heating rods and heating strips
·Infrared anti pinch function for safer worker operation
·Gear sealing locator, sealing without deviation or displacement
·Tsinghua Ziguang reducer, wear-resistant, long service life
·304 stainless steel chain, rust free, non polluting
·Dachang solenoid valve, low failure rate
·Comprehensive fault detection and text based alarm
Customer selection (price varies according to vacuum pump):
Customer packaging site
Continuous Rolling Vacuum Packaging Machine Exhibition Hall


Installation site of continuous rolling vacuum packaging machine



Loading and shipping site
|
serial number |
name |
model |
quantity |
Origin and brand |
|
1 |
stage floorboard |
304 stainless steel 8mm |
1 |
TISCO or Baosteel |
|
2 |
studio |
304 stainless steel 6mm |
1 |
TISCO or Baosteel |
|
3 |
Frame body |
304 stainless steel 5mm |
1 |
TISCO or Baosteel |
|
4 |
solenoid valve |
∅32 globe valve |
1 |
Wenzhou Dachang Brand |
|
5 |
solenoid valve |
∅32 release valve |
1 |
Wenzhou Dachang Brand |
|
6 |
solenoid valve |
∅6. Pressurization |
1 |
Wenzhou Dachang Brand |
|
7 |
Computer control board |
Single or double sealed |
1 |
Laizhou, Shandong |
|
8 |
electrical configuration |
All electrical appliances |
22 |
Delixi and Chint |
|
9 |
Lift reducer |
NMRW |
1 |
Tsinghua Unigroup |
|
10 |
Brake reducer |
NMRW |
1 |
Tsinghua Unigroup |
|
11 |
conveyor belt |
Pvp3mm |
3175mm |
Shanghai |
|
12 |
Conveyor chain |
Fine standard configuration |
100 sections |
Donghua Chain |
|
13 |
Command switch |
ZB2_BE101C |
3 |
Schneider |
|
14 |
Positioning switch |
Z_150cw2_b |
3 |
Omron |
|
15 |
transformer |
1800kw |
1 |
Zhucheng, Shandong |
|
16 |
Water cooled heating rod |
aluminum-magnesium alloy |
1 |
Harbin |
|
17 |
Heating strip high temperature cloth |
cmc |
1 |
Imported from Japan |
|
19 |
Heating wire |
6 square meters |
|
|
Main structure and working principle
This machine is mainly composed of five parts: upper working room, lower working platform, rack, electrical system, and vacuum system. Please refer to the attached figure for details. A vacuum pump extracts air from the working chamber, when
working process:First, close the lid,
Stop working, open the pressure valve, inflate the airbag, automatically deflate and open the lid to complete one working cycle. After the sealing is complete, the vent valve is powered on and opened,
-
Adjustment and use
1Preparation before use
aPlace the machine steadily and check if the lid is closed smoothly, Does it automatically jump after releasing it,DZ -400/2L;The adjustable bolt under the studio allows the thief to jump automatically, but the jumping force should not be too strong;DZ -400/2S. D2-500/2S. D2-600/2S. DZ-800/2SAdjust the left and right screw buckles for the model.
bEquipped with a power supply that meets the requirements of the aircraft model.
e.Check if the position of the vacuum pump oil surface is correct. If not, adjust it(Please refer to the vacuum pump manual for details)”
dGround the machine properly.
e.Connect the power, turn on the power switch, close the cover, and check if the vacuum pump is running normally(If no air is drawn, any two wires in the three-phase power supply line should be replaced).
2Adjustment before use
aChoose vacuum degree
The pumping time is0-60Second digital display continuously adjustable, small vacuum machine, with digital rotary pumping time0-99Adjustable in seconds, adjust the duration of the pumping time to achieve the desired vacuum level.
bSelect heating temperature
Select the desired heating temperature based on the packaging bag material, and adjust the heating temperature knob to the corresponding position, high or medium low.
C.Adjust heating time
heating time0-9.9The second digital display is continuously adjustable. Adjust the heating time knob according to the packaging material and heating temperature used, and select the appropriate heating time(Small vacuum machine digital rotary type0-30Adjustable in seconds) .
dSelect the silicone characters for sealing the silicone rubber strip mouth as needed, and set the sealing date and other characters,
3.use
a、 Turn on the power switch:
b、 Open the pressure strip of the packaging bag and put the packaging bag containing the packaged item inside(The distance from the item to the mouth must not be less than4centimeter)Put it into the studio, place the seal flat on the silicone rubber strip, do not overlap the bags, flip over the packaging bag pressure strip and press the opening of the packaging bag tightly;
CHold the handle tightly(Press down on the edge of the upper cover to press down on the studio. If the lid is closed, the machine will automatically complete the vacuum packaging process according to the program and automatically open the lid. Some equipment is equipped with an emergency stop switch:
D、 Open the pressure strip of the packaging bag, remove the packaging bag, and complete one work cycle,
2
eWhen stopping work, turn off the power switch and unplug the power plug,
4In addition to the above preparations, the fully automatic vacuum packaging machine also needs to:
AAdjust the speed adjustment time relay of the equipment based on the automatic operation speed of the workshop on the equipment and the working speed of the operator,(time Extend or shorten the interval).
bThis device is equipped with an emergency stop switch. In case of special circumstances, pressing this switch will automatically open the upper cover and place it directly above. After the situation is resolved, the emergency stop switch will be turned on to push the upper cover towards the working side, and the device will enter normal working mode