Fully automatic acid reflux cleaning machine UV900
Ultra trace rapid cleaning is your reliable assistant in inorganic analysis work. One click program start, intuitive 9-inch full-color touch screen, p
Product details

Ultra trace rapid cleaning is your reliable assistant in inorganic analysis work

hardware design
Reliable material and efficient cleaning

The fully automatic acid reflux cleaning system UV900 type uses highly corrosive nitric acid during use. The internal cavity structure is made of polytetrafluoroethylene (PTFE) material, and the steam nozzle and ultrapure water spray pipeline are made of PFA (PFA plastic is a copolymer of a small amount of perfluoropropyl perfluoroethylene ether and polytetrafluoroethylene) material, ensuring the corrosion resistance of the machine
Internal cavity structure: Clean the internal cavity of 75L, providing a maximum of 55 cleaning positions, and can clean 55 microwave digestion tanks at a time
• Nitric acid steam cleaning method: Continuously inject ultra pure sub boiling nitric acid steam into the inner surface of the vessel. Using a polytetrafluoroethylene heating plate to heat nitric acid to generate sub boiling vapor, blowing it into the interior of the vessel through a steam duct, and cleaning the vessel with high-temperature and high-purity nitric acid vapor. The nitric acid vapor reacts with ions, condenses, and refluxes. The condensed nitric acid and nitrate liquid flow into the waste liquid pool and wait for the next neutralization treatment
The heating system has accurate temperature control (which can be set in the program) to ensure that the entire cleaning process is carried out in a "sub boiling" state, ensuring sufficient purity of acid vapor and steam generation
• Recommended acid consumption: 100ml nitric acid for one cleaning (analytically pure, the consumption can be adjusted in the system), heating power 1000W

Pure water spraying and drying
The organic material spray water pump is used to provide a maximum spray speed of 240L/min, spraying ultrapure water into the interior and exterior of the vessel, consuming 8L of ultrapure water each time, and can spray multiple times
HEPA drying method: Due to the extremely low detection limit of ICP-MS, the dried air is filtered by HEPA and sent into the interior and cavity of the vessel, with a maximum air volume of 55m ³/h
Real time negative pressure exhaust is adopted, and the exhaust duct is equipped with alkaline substance absorption and filtration to reduce environmental pollution

security guarantee
The UV 900 fully automatic acid reflux cleaning system provides functions such as nitric acid vapor filtration, neutralization of nitric acid waste liquid, temperature protection for nitric acid liquid heating, and over temperature protection for drying gas heating.

software design
Easy to use, intelligent and flexible
Thermo AMASWS intelligent washing software automatically controls the entire process without the need for manual intervention
Adopting a 9-inch LCD full-color touch screen input mode, microcomputer control system, built-in 10 standard cleaning programs, real-time display of operating temperature curve, time, operating status and other information
The instrument has the function of automatically adding nitric acid and discharging waste acid
Before discharging waste acid, perform alkaline compensation and check the neutralization effect with an online pH meter
During the entire acid cleaning process, the machine adopts real-time negative pressure exhaust, and the exhaust duct is equipped with alkaline particle absorption filtration to reduce environmental pollution
The UV 900 model provides a flexible cleaning solution: the perfect combination of all components and program parameters can achieve ideal cleaning results

Product Features

Ultra clean, residue free
60-90 minutes of acid vapor can ensure that the residual in the microwave digestion tank is reduced to below PPT level or not detected by ICP-MS, allowing inorganic analysts to achieve ultra clean cleaning of the microwave digestion tank

Extreme cleaning
Efficient nitric acid sub boiling gas generator, continuously counter flowing using anti-corrosion isolation temperature measurement technology, more accurate. Ensure the generation of sub boiling acid gas by controlling the temperature through a microcomputer.

One click completion, high cleaning efficiency
Thermo AMASWS intelligent washing software allows for one click program startup, with an intuitive 9-inch full-color touch screen. It offers 10 cleaning programs to choose from, including the most efficient nitric acid vapor continuous counter current combined with 8L ultra pure water spray, which can be completed within 1 hour.

Environment and Human Health
Exhaust gas is filtered, and waste liquid is discharged for online neutralization and full negative pressure exhaust, ensuring no sour leakage and keeping experimental researchers away from traditional acid tanks for soaking.

Application:

ICP-MS laboratory, trace cleaning of microwave digestion tank

AAS laboratory, trace cleaning of microwave digestion tank

Clean small bottles, vessels, and ICP-MS accessories made of various materials such as glass, quartz, PFA, PTFE, TFM, etc