Product Introduction
Each instrument has been verified by the Central South National Metrology and Testing Center to ensure that its indicators fully comply with the standards of GB6566-2010 "Limits of Radionuclides in Building Materials", GB5101-2003 "Sintered Ordinary Bricks", GB13545-2003 "Sintered Hollow Bricks and Hollow Blocks", GB50325-2010 "Code for Indoor Environmental Pollution Control of Civil Building Engineering", GB/T18883-2002 "Indoor Air Quality Standards" issued and implemented by the General Administration of Quality Supervision, Inspection and Quarantine of China. It can quantitatively analyze the content of gamma radioactive nuclides in various media such as building materials and their products, food, water, health disease control, environmental protection, geological samples, building materials quality inspection, marble, cement, granite, radiation protection, grain quality inspection, etc.
Fully automatic low background multi-channel gamma spectrometerTechnical parameters:
·The working environment temperature is 0-50 ℃, and the working environment humidity is ≤ Rh90%
·Measurable energy range: 20Kev~10Mev
·Energy resolution: ≤ 7.0% (137CS), energy linearity ≤ ± 1%
·Lead chamber measurement background ≤ 180CPM, stability: 24-hour peak drift ≤ 1%
·When the sum of the specific radioactivity of 226Ra, 232Th, and 40K in the sample is greater than 37Bq/kg, the total uncertainty of the measurement extension of this instrument shall not exceed 10% (K=2)
·Measurement time: 0-200000 seconds, optional
·Multi channel analyzer: 1024/2048/4096 channels
·Analysis of nuclide types: 226Ra, 232Th, 40K, 222Rn (other nuclides such as 238U, 137Cs, 60Co can be expanded according to user requirements)
·The analysis software has a pure Chinese interface and features automatic spectrum collection and peak finding functions. It can be operated with a mouse, making it convenient and easy to use
·According to the requirements of GB6566-2001, the radioactive nuclide content and internal and external irradiation index can be automatically calculated
·Host power: ≤ 20W (excluding computer and printer)
Fully automatic low background multi-channel gamma spectrometerto configure:
·Lead chamber: lead equivalent thickness of 10cm, inner diameter of 22cm
·One gamma spectrometer host
·One Φ 75 high-sensitivity radiation detector
·One set of FYFS-2002F system operating software (with one CD)
·Selection of Activated Carbon Radon Measurement System (Activated Carbon+Sample Box+Analysis Software)
·One standard source each for radium, thorium, and potassium, or one standard mixed source
·10 radioactive standard sample boxes
·One set of instrument connecting wires
·Instrument calibration certificate
·Factory certificate and packing list copies
·One user manual
·A set of branded computers
·One branded printer