GC1690Q gas chromatograph Jiedao GC1690Q (dual FID+dual SPL+single amplification plate) gas chromatograph
GC1690Q gas chromatograph Jiedao GC1690Q (dual FID+dual SPL+single amplification plate) gas chromatograph
Product details

Jiedao IslandGC1690Q(twoFID+twoSPL+Single amplification board)Introduction to Gas Chromatography:

Product Name: Gas chromatograph
Specification and model:GC1690Q(twoFID+twoSPL+Single amplification board)

Manufacturer: Jiedao

Host Introduction:GC1690The series of high-performance gas chromatographs is a laboratory analytical instrument launched by Jiedao Company, which can be optionally combined with hydrogen flame ionization according to usage needs(FID)The Thermal conductivity(TCD)Two types of detectors that can detect boiling points399.CPerform constant, trace, and even trace analysis on the following organic, inorganic, and gas substances. Widely used in fields such as petroleum, chemical, fertilizer, pharmaceuticals, electricity, food, fermentation, environmental protection, and metallurgy.
Basic configuration:GC1690Q(twoFID+twoSPL+Single amplification board)

column oven

Taking into account the thermal radiation generated by the heating of the gasification chamber or detector, the high-performance column temperature box is designed as an upright structure to achieve maximum operating temperature420,Temperature range+7~420℃,5Step program temperature rise, automatic rear door opening, can be set420Temperature for use at heights within ℃, fixed450℃ independent protection circuit with dual protection structure.

injector

1.Fill the column with samples

2.shunt/splitless

3.Large caliber capillary tubeWBCinjection

4.Filling column vaporization injection

5.Six way valve air inlet style

Jiedao IslandGC1690Q(twoFID+twoSPL+Single amplification board)Technical parameters of gas chromatograph (column temperature chamber):



column

warm

box

Temperature range

room temperature+7~420

Temp Accuracy

be better than±0.1

Internal volume

240×160×360

Program order

5steps

heating rate

0.1~39.9/minAny setting

heating up time

0~665min(increment1min)

*1 Over temperature protection: When the actual temperature of each hot zone exceeds the set maximum value, the over temperature protection device works, automatically cutting off the power supply of each heating zone of the instrument, and sounding an alarm to avoid accidents.

*2Overcurrent protection: WhenTCDWhen the detector is working, if the current is set too high orTCDWhen the resistance suddenly increases, the overcurrent protection device works and automatically cuts offTCDBridge current, alarm and display simultaneouslyOVER TCDTo protect the tungsten wire from burning out (if the user starts it without gas supply due to operational errors)TCDThe device can also automatically cut off the power to protect the tungsten wire. Amplification circuits can also be added to increase sensitivity.

*3 Crash protection: When the instrument is in operation, it can automatically cut off the power and sound an alarm in case of short circuit or open circuit of the thermistor in each heating zone, grounding of the heating wire, or system crash of the microcomputer operating system, to avoid accidents caused by continuing to work. The above three protection functions can make your analysis work safer and more reassuring.

Six major temperature controls

GC1690The gas chromatograph is capable of six temperature control channels, among whichAUX1Control external heating device, column temperature andAUX1Equipped with a five stage program for heating up.

Pneumatic control

The gas path controller adopts an external type, with capillary gas path box and gas combustion assisting gas path box placed independently. The airflow ratio adjustment is intuitive and easy to understand, and the control is flexible. Moreover, once a certain gas path problem occurs, it can be immediately switched, which has no impact on the operation of the host and is easy to maintain.

Low noise

Each fan blade inside the host is molded in one go using molds, with good symmetry to avoid imbalance and noise during operation.

Flexible configuration

The capillary injector is independent and can be configured with dual capillary injectors and dual amplification plates according to user requirements, allowing for the simultaneous installation of two capillary columns; Two filling columns can also be installed simultaneously; It is also possible to install both a packed column and a capillary column simultaneously; It can also be flexibly increased on this basisTCDFPDNPDECDDetector to meet different analysis requirements; One instrument can be equipped with up to three types of injectors and three types of detectors.

Beautiful appearance

Using a vertical column box, it has a beautiful and elegant appearance, and occupies a small area, suitable for use in small laboratory spaces.

belt“*'Indicates that the technology is domestic *.

Jiedao IslandGC1690Q(twoFID+twoSPL+Single amplification board)Technical parameters of gas chromatograph (detector):

index

detector

Sensitivity or sensitivity

drift

noise

linear range

Hydrogen flame(FID

Mt≤1×10-11g/s

≤1×10-12(A/30min)

≤2×10-13A

≥106

heat conductance(TCD)

S≥2000mV . m1/mg

≤0.1(mV/30min)

≤0.01mV

≥106

flame(FPD)

P≤2×11-12g/s

S≤5×10-11g/s

≤4 ×10-11 (A/30min)

≤2×10-11A

P ≥103

S ≥102

nitrogen(NPD)

N≤1×10-12g/s

P≤5×10-11g/s

≤2 ×10-12 (A/30min)

≤4 ×10-13A

≥103

Electron capture(ECD)

≤2×10-13g/ml

≤50(uV/30min)

≤20uV

≥103