GDS-2000The series of digital storage oscilloscopes adoptsall-in-oneDesign, including1GSa/sReal time sampling rate,25kMemory length2perhaps4ChannelTFTcolorLCDDisplay and supportUSBInterface, direct printing function of printer, battery power operation, and up to27The powerful automatic measurement function of the item.
GDS- 2000The series of digital storage oscilloscopes includes200MHz/100MHz/60MHzBandwidth2perhaps4The channel's6Types of models. Among products of the same level in today's marketGDS-2000Series to1GSa/sReal time sampling rate(25GSa/sEquivalent sampling rate) and25kThe length of the record…Provide a better platform for testing environments.27Automatic measurement functionFFTMeasurement, advanced trigger options 12Grid wide horizontal display, time display, frequency counting functionGO/NO-GOFeatures, multi language menu, real-time online help function description, and loop measurement function are all includedGDS-2000Series digital storage displayOne of the many functions of a waveguide.
now, GWInstekAdhering to the customer-oriented philosophy,GWInstekIn addition to providing consumers with the highest quality products, we have a deeper confidence in product quality, so in order to give backGWInstekofConsumers have decided to launch globallyGDS-2000series2Channel and4The global lifetime warranty plan for channel digital storage oscilloscopes is considerate, allowing consumers to use them with the most peace of mindGWInstekHigh quality digital oscilloscope.
4CH & 2CH Selection
|
4-channel models have joined the product lineup in addition to the traditional 2-channel models. The vertical scale of each channel carries the full bandwidth of the model at 200MHz, 100MHz or 60MHz. With 4 full bandwidth channels, a larger range of applications are possible. Typical examples of four-channel applications include testing switching power supplies and rotary encoder measurements.
|
|
1GSa/s Real-time Sampling & 25GSa/s Equivalent-time Sampling
|
1GSa/s Real-Time Sampling allows measure high frequency signals accurately. A higher sampling rate helps to acquire more waveform data in a short period of time. It is especially useful for the single-shot (non-repetitive) waveform capture and observation as the faster the waveform data can be acquired the better the waveform reconstruction. For repetitive signals, however, Equivalent-Time (ET) sampling is a better tool than Real-Time Sampling. ET sampling is able to acquire data periodically, with each successive sample increasing the sampling points. By acquiring data from repetitive waveform cycles, ET Sampling Technology accurately reconstructs the waveforms at a resolution of up to 40ps. The GDS-2000 Series is able to sustain a 25GSa/s sampling rate for repetitive waveform acquisition and reconstruction compared to a Real-Time Sampling capability of 1GSa/s rate.
|
|
TFT Color LCD Display
|
|
For a crisp and clear view, the GDS-2000 Series has a color TFT LCD display. Compared to STN displays, TFT panels have reduced flicker, wider viewing angles and brighter color reproduction. With support for displaying 4 waveforms, measurement grids and signal data at the same time, a bright, clear, colored screen is a necessity for comparing and analyzing data.
|
|
27 Automatic Measurements
|
|
The GDS-2000 DSO Series employs a comprehensive set of automatic measurement features. The automatic waveform measurement feature includes 27 frequently used measurement items grouped into three sections : Voltage, Time (Frequency), and Delay. A maximum of 10 measurement results can be shown on the screen and updated in real-time. These automatic measurement features are an effective way to monitor the characteristics of a signal in real-time. 19 automatic measurements can be shown on screen simultaneously.
|
|
Go/NoGo Testing
|
|
The Go/NoGo testing function checks whether an input signal violates a user-defined template. Setting the template is a simple two -step process. Select a reference waveform from an input signal or waveform file and configure the violation tolerance from the reference waveform. After setting the template, Go/NoGo testing is ready to go. The GDS-2000 Series compares the input signal with the template in real time and shows the test result on the screen. Both the type of Go/NoGo violation and the reaction to a violation can be configured to meet various application requirements. Any Go/NoGo violations are indicated either by an internal buzzer or by sending a control signal to an external device via the Go/NoGo BNC output on the rear panel.
|
|
On-Line Help And Multi-Language Support
|
|
For hassle-free operation, the GDS-2000 Series provides a built-in help manual via the Help key. Press the "Help" button to get into the on-screen Help mode, and then press any key to display instructions about that key's function on the screen. The GDS-2000 Series interface menu and the on-screen Help have multi-language support. Supported languages include: English, Russian, Spanish, Korean, German, Japanese, Traditional and Simplified Chinese. This provides localized help if English is not your preferred language and offers an easy environment for multicultural joint-projects. In the future, GW Instek will increase the number of languages to provide broader localized support for languages that are not currently supported.
|
|
Data Storage & Transfer And USB Printing Support
|
|
20 sets of waveform data, 20 panel setups and 4 reference waveforms can be saved into internal memory to be recalled later for display. All the waveform data, panel setups and screen images can be saved to a USB flash drive.
With optional PC software available for download on the GW Instek web site, the GDS-2000 series can be remotely controlled.
The software can also monitor and record waveform data over a period of time by continually transferring data to a PC for further analysis. The GDS-2000 Series supports printing directly to a USB compatible printer. Screen images can be printed in either color or grayscale depending on the printer settings.
|
|
BatteryPower Operation
|
|
With the optional Li-ion battery packs, the GDS-2000 Series market coverage is extended to field application areas where AC power is not available. Fully charged, the two light-weight battery packs keep a GDS-2000 DSO running under normal operation for over 3 hours.
The built-in battery charger automatically recharges the battery packs whenever the oscilloscope is connected to AC power. An optional soft carrying case (GSC-005) is available to accommodate field applications.
|
Vertical system
|
Number of channels
|
2/4
|
bandwidth
|
DC ~ 200/100/60MHz (-3dB)
|
rise time
|
make an appointment1.7ns/3.5ns/5.8ns
|
sensitivity
|
2mV/div ~ 5V/div (1-2-5Stepping)
|
accuracy
|
±(3% x |Read the numerical value|+0.05 div x Volts/div+0.8mV)
|
Input Coupling
|
AC, DC &grounding
|
Input impedance
|
1M±2%, ~ 16pF
|
polarity
|
Forward, reverse
|
Maximum input
|
300V (DC+AC peak), CATII
|
Waveform signal processing
|
+ , - , x, FFT, FFTrms
|
Offset Range
|
2mV/div~20mV/div: 0.5V; 50mV/div~200mV/div: 5V; 500mV/div~2V/div: 50V; 5V/div: 300V
|
Bandwidth limitation
|
20MHz (-3dB)
|
TRIGGER
|
Trigger Type
|
CH1 , CH2 , CH3 , CH4 , Line
|
MODE
|
Automatic level,automatic,ordinary,Single time, TV,edge,Pulse width,time delay,event delay
|
Trigger coupling
|
AC , DC ,Low frequency suppression,High-frequency suppression,Noise suppression
|
Trigger sensitivity
|
DC ~ 25MHz :make an appointment0.5divperhaps5mV; 25MHz ~ 200MHz :make an appointment1divperhaps10mV
|
horizontal system
|
Scan range
|
1ns/div ~ 10s/div (1-2-5Stepping);Scroll Mode: 250ms/div ~ 10s/div
|
display mode
|
Main time base,window,Window enlargement,roll,scan, X-Y
|
Accuracy Error
|
±0.01%
|
Pre trigger
|
maximum20 div
|
Post trigger
|
1000 div
|
X-Ymode
|
X-Axis input
|
thoroughfare 1
|
Y-Axis input
|
thoroughfare 2
|
phase shift
|
±3°exist100kHz
|
Signal acquisition system
|
Real time sampling rate
|
maximum1GSa/s
|
Equivalent sampling rate
|
maximum25GSa/s
|
Vertical Resolution
|
8 position
|
Record length
|
maximum25Kdrop
|
Acquisition mode
|
sampling,peak detection,average,summation
|
Peak measurement
|
10ns
|
Average frequency
|
2 , 4 , 8 , 16 , 32 , 64 , 128 , two hundred and fifty-six
|
Vernier and measurement system
|
voltage measurement
|
Vpp , Vamp , V avg , Vrms , Vhi , Vlo , Vmax , Vmin , Rise Preshoot/ Overshoot , Fall Preshoot/Overshoot
|
Time measurement
|
frequency,cycle,rise time,fall time,Positive pulse width,Negative pulse width,Duty cycle
|
delay measurement
|
8Delay measurement
|
Vernier measurement
|
ΔV,ΔT
|
frequency counter
|
resolution: sixposition
accuracy: ±2%
signal source:All available trigger sources except for video trigger mode
|
Control panel functions
|
Automatic setting
|
Automatic adjustment of vertical system, horizontal system, trigger level
|
storage
|
up to20Panel settings
|
Waveform storage
|
4 Group reference waveform,common 24 group
|
display
|
TFT LCD
|
5.6 inch
|
display resolution
|
234 x 320drop
|
Display grid lines
|
8 x 10check; 8 x 12check(Close menu)
|
display luminance
|
adjustable
|
interface
|
Go/NoGooutput
|
5Vmaximum/10mA TTLlevel,open-collector
|
RS-232interface
|
DB 9-needleVGADTE RS-232interface
|
GPIBinterface(Optional)
|
compatibleIEEE 488.2standard
|
USB
|
USB Host/Device 2.0full speed
|
power supply
|
Voltage range
|
AC 100V ~ 240V , 48Hz ~ 63Hz ,adaptive
|
battery(Optional)
|
battery: 11.1VLithium battery pack
charging time: eighthour
Usage time: threehour,Use according to actual situation
|
Other functions
|
Multi language menu
|
have
|
Online Help
|
have
|
Real Time Clock
|
Time and date,Provide storage time and date
|
Size and Weight
|
254D x 142H x 310W(mm)
make an appointment4.3kg
|
ordering information
GDS-2204 200MHz,Four channel colorLCDDigital Oscilloscope GDS-2202 200MHz,Two channel colorLCDDigital Oscilloscope GDS-2104 100MHz,Four channel colorLCDDigital Oscilloscope GDS-2102 100MHz,Two channel colorLCDDigital Oscilloscope GDS-2064 60MHz,Four channel colorLCDDigital Oscilloscope GDS-2062 60MHz,Two channel colorLCDDigital Oscilloscope
choose and buy
Opt. 01: GPIBinterface
Opt. 02:Battery Power Operating System(Includes battery charging circuit and two high-efficiency lithium-ion batteries) (This project is arranged before leaving the factory,Confirmation is required at the time of placing the order. )
accessory
power linex 1
operation manualx 1 GTP-250A-2: 250MHz (10:1/1:1)Passive measuring rod, used forGDS-2202/2204 (One per channel) GTP-100A-4: 100MHz (10:1/1:1)Passive measuring rod, used forGDS-2102/2104 (One per channel) GTP-060A-4: 60MHz (10:1/1:1)Passive measuring rod, used forGDS-2062/2064 (One per channel)
Option
GRA-405rack(19", 4U) GSC-005Portable soft backpack GTL-110 BNC-BNCTest cable GTL-232 RS232Communication cable, 9 pin female to 9 pin, Null modem for computer GTL-242 USB 2.0 A-BtypeCable line GTC-001Mobile chassis for instruments, 450(W) x 430(D)mm (120VPower socket) GTC-002Mobile chassis for instruments, 330(W) x 430(D)mm (120VPower socket)
|