product overview
Vaisala's GMP343 soil respiration carbon dioxide sensor is designed for high-precision carbon dioxide measurement, based on advanced CARBOCAP single beam dual band NDIR technology. The GMP343 soil respiration carbon dioxide sensor consists of a carbon dioxide sensor, electronic components, and a housing suitable for long-term field use. There are two models available for users to choose from, flow type and diffusion type. The output signal of the sensor can be adjusted to output voltage or current signals (0-2.5V, 0-5V, 4-20mA), and digital RS-232/RS-485 signal output can also be applied. The measurement range is from 0-1000ppm to 0-2% carbon dioxide.
Users can configure the output of the GMP343 soil respiration carbon dioxide sensor. They can use raw data without filtering or compensation, or they can choose filtering conditions, compensation conditions (temperature, pressure, relative humidity, oxygen), and linearization. Widely used in CO2 soil respiration, ambient temperature CO2 monitoring, plant growth chambers, and OEM applications. The use of diffusion ventilation to eliminate errors caused by pressure differences in pump sampling can be used for soil carbon dioxide monitoring.
Product Features
uExcellent accuracy and stability
uUsed in harsh environments
uThere are two types: diffusion and flow
uWide temperature and humidity range for operation
uOptional temperature, air pressure, humidity, and oxygen compensation
uLow power consumption and thermal diffusion
uShort hot start time
uCompact and lightweight structure
TECHNICAL INDEX
Probe
Vaisala CARBOCAP ®
measuring principle
Single beam dual wavelength NDIR
Range selection
0~1000ppm,0~2000ppm,0~3000ppm,0~4000ppm,0~5000ppm
Accuracy after calibration by the manufacturer
(0.5% gas)
± 2.5% reading
At the CO2 calibration point
± 1.5% reading
Below 300ppm
±5ppmCO2
Short term stability (6 hours)
± 5ppm CO2, (at 350ppm CO2)
Long term stability
± 2% reading per year; ± 2% reading/6 months; ± 2% reading/3 months
Flow dependence on liquidity
0.3% reading/liter/minute
Hot start time
Full accuracy ± 0.5%, 10 minutes; Full precision, 30 minutes
Pressure compensation range
700~1300hpa
Flow type velocity
<10 liters/minute
electromagnetic compatibility
Compliant with EMC standard EN61326-1:1997+Am1:1998
Power supply
10~36VDC
Power consumption
< 1W, no heating; Maximum 3.5W, including heating
current output
4~20mA
Resolution
14 positions
Voltage Output
0~2.5V,0~5V
Resolution
14 positions
Minimum load
5000 euros
TEMPERATURE DEPENDENCE
± 0.005% reading/℃
Digital Output
RS-232,RS-485
Probe body material
Anodized aluminum plating
Filter housing material
plastics
Protection level
IP66/IP67
CONNECTORS
8 needles, M12
Weight
360g, probe only
Size
Diameter 55mm, length 180mm