Product Introduction
The binder FDL series is suitable for safety/paint drying ovens with limited solvent capacity and meets the EN1539 safety standard. The symmetrical diversion method and established air flow rate are used for the internal air flow to ensure the good stability and importance of the equipment. The precise definition of non-volatile components (based on the NFA of ISO3251) ensures the safety of use. The dust-free inner cavity sealed with siliceous material can reliably prevent the surface of the dried sample from undergoing non compliant changes. The large-area filter ensures higher filtration efficiency and can reliably filter out suspended impurities in the air. The overall replacement of the filter is very convenient, avoiding residue from entering the inner cavity.
BinderThe outstanding advantages of a safe oven
Binding Core Technology - APT.Line@Internal preheating technology enables the temperature inside the cavity to reach a very uniform distribution, changing the traditional preheating system's difficulty in overcoming the temperature difference between the upper and lower neck bottles.
1) Ensure high control accuracy within the entire available space, and the control accuracy can be reproduced.
2) The temperature distribution is relatively uniform, and the temperature adjustment process is smooth and stable.
3) Due to APT Line@The air conduction performance ensures precise control of space temperature even under full load conditions.
FDLseriesSafe ovenTechnical features
1) Electronic control APT.line@Internal preheating technology;
2) According to EN1539 and VBG24 standards, it meets all safety requirements;
3) Temperature range: ambient temperature+5 ℃ to 300 ℃;
4) MS controller, LED LCD display, and 0-99 hour and 59 minute timer;
5) Controller timer function: delayed opening, delayed closing, and temperature dependent delayed closing;
6) Adjustable heating load (0-100%);
7) Single slope function;
8) Equipped with fluororubber box door sealing strip;
9) A replaceable fresh air filter, F6 grade (EU6 particulate filter, used to filter particles between 1 μ m and 10 μ m in size);
10) Independent adjustable temperature safety device, level 2 (DIN 12880), with sound and light alarm;
11) Continuous monitoring of fresh air entering the internal cavity, equipped with sound alarm and automatic heating cut-off function;
12) Rear exhaust pipe, diameter 100mm;
13) Used for communication software APT-COM@RS 422 interface of data control system;
14) 2 chrome plated shelves
model |
FDL 115 |
External dimensions (W × H × D) (mm) |
834×800×685 |
Internal cavity size (W × H × D) (mm) |
600×435×435 |
Internal cavity volume (L) |
115 |
Stainless steel shelving (standard/maximum) |
2 / 5 |
Load per shelf/total load (kg) |
20 / 50 |
Temperature range: ambient temperature+5 to (° C) |
300 |
Temperature deviation @ 70 ° C (± ° C) |
1.5 |
Temperature deviation @ 150 ° C (± ° C) |
2.5 |
Temperature deviation @ 300 ° C (± ° C) |
4 |
Temperature fluctuation range (± ° C) |
0.3 |
Heating time to 70 ° C (min) |
7 |
Heating time to 150 ° C (min) |
17 |
Heating time to 300 ° C (min) |
44 |
Recovery time (30 seconds after opening the door to 70 ° C) (min) |
1 |
Recovery time (30 seconds after opening the door to 150 ° C) (min) |
3 |
Recovery time (30 seconds after opening the door to 300 ° C) (min) |
6 |
Air exchange rate (times/minute) |
3 |
Air circulation (times/minute) |
40 |
Exhaust volume flow rate (liters/minute) |
400 |
Air velocity (m/s) |
0.8-1.2 |
Maximum allowable weight of solvent (grams) (at T-180 ° C, M-100g/mol, K=0.5) |
6.65 |
Power supply (± 10% 50/60 Hz) |
230V/2.9KW |
Net weight (kg) |
90 |