Guangzhou Keshite Scientific Instrument Co., Ltd
Home>Products>Glow discharge cleaning system
Glow discharge cleaning system
Glow discharge cleaning system
Product details
Item number: 91000S
supplier: Guangzhou Keshite Scientific Instrument Co., Ltd
Spot status: 1 month
defects liability period: 1 year
quantity no limit
Specifications: 0-30 mA
PELCO easiGlow ™ Glow discharge cleaning system - used for cleaning TEM grids

For one of the most common glow discharge applications, air is used toTEMThe supporting membrane or grid has hydrophilicity,PELCO easiGlow™ Use automated fast loops with fully selectable parameters. The microprocessor control system also provides fully manual control for all parameters and advanced protocol programming capabilities for custom designed glow discharge applications. Parameters and protocols can be stored to facilitate consistent glow discharge results. Open the packaging box, insert it, and then you can start.

PELCO easiGlow™ The glow discharge cleaning system is a compact, fast, and easy-to-use standalone system. It is mainly used for cleaningTEMGrid andTEMHydrophilization of carbon supported membranes, which possess hydrophobicity. Using air for glow discharge treatment will make the surface of the carbon film negatively charged (hydrophilic), which makes the aqueous solution easy to diffuse. Made in the United States.

With the increasing demand for imaging applications, clean and consistent high-quality use is essentialTEMGrid and support are more important than ever before.TEMThe glow discharge treatment of the grid removes adsorbed hydrocarbons, cleans them while making them hydrophilic.PELCO easiGlow™ It is an affordable and easy to operate glow discharge system that is suitable for anyTEMlaboratory.

Practical chamber size, newly designed glow discharge head, and adjustable platform with glass sliding bracket for easy loading and fast turnover time. The system is fully controlled by a microprocessor, including an intelligent touch screen device for controlling and displaying operational parameters.PELCO easiGlow™ Supports hydrophilic and hydrophobic treatment with negative or positive charges, and includes two independently controlled gas inlets. The required vacuum level is set by an electronically controlled precision proportional valve. This novel method eliminates the need for manual setting using needle valves. Gentle ventilation procedures ensure that there is no interference during system ventilationTEMGrid.


PELCO easiGlow™ Has efficient glow discharge performance and optimal pressure within a given distance from the sample to the glow discharge head
Support glow discharge method:
Surface Condition charge atmosphere
Hydrophilicity burden air
Hydrophilicity straight Air (subsequently treated with magnesium acetate)
hydrophobic straight Pentamine
hydrophobic burden Methanol

Reference glow discharge and use of amine to obtain hydrophobicity;A positively charged surface:HayatMA2000Principles and Techniques of Electron Microscopy in Biological Applications, Section237-241Page. Cambridge University Press. International Standard Book Number052163287
Obtained by reference glow discharge and subsequent treatment with magnesium acetateHydrophylic;Charged surface:PortmannR. AndKollerTh.1976.The bivalent cation method for nucleic acid molecules without protein diffusion. In the proceedings of the 6th European Electron Microscopy Conference2Volume, Section546Page.
  • Optimized for cleaningTEMgrid
  • Accurate and convenient vacuum setting
  • Short cycle time
  • Consistent results
  • Automatic, programming, and manual modes
  • Intuitive touch screen for display and operation
  • Supporting hydrophilicity/Hydrophobic and Negative/holotype
  • Economical and compact independent system
plasma current 0-30milliampere
high voltage 30Wcontinuous rating
Polarity of glow discharge head Users can choose between positive or negative
Process Platform Ø75mmWith grooves, suitable for25 x 75mmslider
Glow discharge platform height control 1-25mm
Preprocess hold timer 0-14411second
Processing Timer 0-900second
Room size Ø120x100mm H, with sealingDelrin®Top plate (internal)Ø106x90mm
handle/Exhaust intake port 2individualØ6Millimeter strap hook, can be individually selected by users for processing, blowing or exhaust
High pressure vacuum interlock Dual hardware and software interlocking
vacuum control Pirani GaugeFrom atmospheric pressure to0.01millibar
Working vacuum range 1.1 - 0.20 mbarTo achieve the best luminous effect
system control/display 3Touchscreen withLEDBacklight and5A function key
MODE Automatic programming(4User Programming Protocol) Manual/diagnosis
Data recording function Step #, Vacuum(mbar), current(mA), voltage(V)And polarity, once per second
Instrument dimensions 305 d x 230mm 292 L X H12“×11“×9 1 / 2”)
weight 6.26Kilogram(13.8Pound)
GD4Pump (optional) 337 L X H13.3 244mm 138 D XX5.4“×9.6
weight 11Kilogram(24Pound)
Laboratory footprint, optional pump 381 W X D X H292mm15X 11 1 / 2“×13“)
Power requirements 120V 60Hz15Aperhaps230V 50Hz10Aservice
Instrument power level 100-240VAC 60 / 50Hz 60W PlusPump,IECentrance
Optional pump power rating 120 / 230V 6050Hz 370 W12HP
Minimum requirements for vacuum pumps 2.5rice3/Hour,41rise/Mi,1.65CFM
3Millibar limit vacuum
Vacuum pump power socket on the instrument 8AmaximumIECsocket
Vacuum suction port KF 16flange
Data recording function Step #, Vacuum(mbar), current(mA), voltage(V)And polarity, once per second
Communication port USBsocket
For laboratories that require hydrophilic and hydrophobic surface treatment on conventional bases, a dual glow discharge system can be used to avoid cross contamination of the glow discharge chamber. When using organic solvents, hydrophobic surfaces are preferred.
For ease of ordering, we have created a set that includes low-temperature optionsEMAll items required for a typical glow discharge setup in the laboratory. exceptPELCO easiGlow™ In addition to the device, this convenient device also includes a specially matched vacuum pump with all accessories, a rubber gasket for protecting the edges of the glass chamber, and aPELCO ®Grid bracket blockA convenient alternative to placing your grid on a glass slide.
Product # describe
91000S newPELCO easiGlowCryo-EMGlow discharge device
91000 PELCO easiGlow™ Glow discharge device
91002 Double chamberPELCO easiGlow™ Glow discharge system
91050 Replace the glass chamber and seal the top plate
91000-2 Replace the touch screen stylus
91051 Used for glow discharge chambersORing
91053 91050protectionLType washer

Due to the optimization of the vacuum degree in the glow discharge program0.45to1.1Within the millibar range, we offer affordable optionsGD4A two-stage rotary vacuum pump system designed specifically for this pressure range.
pumping speed Pipeline(72 tf267/Hour,2.5 LminCFM @ 60Hz
3.6rice3/Hour,60rise/minute,2.1CFM @ 50Hz
Ultimate vacuum 1 x 10millibar-2
vacuum connection KF/NW 16
Exhaust connection KF/NW 16
CAPACITY 300cc(Including)
operation temperature 5 - 40°C (41 - 104°F)
External dimensions 337 x 138 x 244mm
13.3" x 5.4" x 9.6" (L x W x H)
weight 11kg/ 24pound
rated power 110 115V 60Hz 3.2a, saw
220-250V1.6a 50 / 60Hertz, saw
Product # describe
91040 GD4Vacuum pump system,4.3m³/ hrConnection kit,115V60Hz
91040-230 GD4Vacuum pump system,3.6m³/ hrConnection kit,230V50 / 60Hz
91042 GD4Vacuum system,4.3cubic meter/Connection kit with dual chamber glow discharge system for hours,115V60Hz
91042-230 GD4Vacuum system,3.6cubic meter/Connection kit with dual chamber glow discharge system for hours,230V50 / 60Hz
9609 GD4perhapsGD7Exhaust filter of rotary vacuum pump
891-31 PELCO®used forGD4GD7andGD8PumpUltragrade 19Vacuum pump oil,1 ltr
91010-16 PELCO easiGlow™ Vacuum connection kit toKF16pump inlet
91010-25 PELCO easiGlow™ Vacuum connection kit toKF25pump inlet
12938-3 Polypropylene funnel, three piece set, consisting of2,4and8ounce
808-16 Cotton ShopCleaning towel, blue,14x 14

TEMGrid bracket block
Two sizes are available:5 x 5In the matrix25individualTEMGrid and9 x 9In the matrix81individualTEMGrid.
Product # describe
16820-25 used for25individualTEMThe grid'sTEMGrid bracket block
16820-81 used for81individualTEMThe grid'sTEMGrid bracket block

clampTEMGrid bracket block
support45A grid is firmly sandwiched between two boards.
Product # describe
16830-45 PELCO®used for45individualTEMClamping of the gridTEMGrid bracket block

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!