Beijing Oriental Peak Technology Co., Ltd
Home>Products>Gordon Plan, Schmidt Belt Plan
Gordon Plan, Schmidt Belt Plan
Customizable/High Accuracy/Industry Standard
Product details
model 64-xx-16 64-xx-17 64-xx-14 64-xx-15
Heat flow type Total radiation+convective or radiative heat flux (requires sapphire window)
Spectral response range Full wavelength
Sensing area φ10mm
mounting structure flange mounting Threaded body+flange Smooth without flanges Threaded body
range 4000/3000/2500/2000/1500/1000/500/250/200/100/50/30/25/20/15/10/5/2/1/0/5/0.2 Btu/(ft².s) ①
operation temperature The sensor body has a temperature resistance of 205 ℃ (it can be used in higher temperature environments when cooled by water)
response time 250~4000Btu/(ft².s) : Less than 50ms
50~200 Btu/(ft².s) : Less than 100ms
2~30Btu/(ft².s) : Less than 250ms
accuracy 2% of the measuring range
output signal Linear output, with a full-scale signal output of 10mV
cooling Water cooling, the outlet cooling water is not allowed to boil (recommended minimum water flow rate of 3L/min, the faster the better)

① Heat flow unit conversion relationship: 1 Btu/(ft ². s) ≈ 10 kW/m ²