HCB electronic electric control valve
Working temperature: high temperature or room temperature
Flow direction: Unidirectional
Applicable media: water, steam, oil, various highly corrosive chemical media, weak acid-base media, ammonia, nitrogen, oxygen, hydrogen, liquefied gas, air
Pressure environment: high pressure or normal pressure
Connection type: flange
Nominal diameter: 50-350 (mm) mm
model: TJF
Material: Stainless steel
Customized processing: Yes
Brand: Zhongren
Standard: National Standard
Sealing form: hard seal, soft seal
Form: Straight through type
Type (channel position): Binary formula
Drive mode: electronic, pneumatic, electric
Parts and Accessories: Accessories
HCB cage type regulating valve is a pressure balanced regulating valve equipped with a guiding wing to improve the smooth flow of fluid around the sleeve. Its advantages include low pressure drop loss, large flow rate, wide adjustable range, high accuracy of flow characteristic curve, good dynamic stability, low noise, and minimal cavitation corrosion. The regulating valve is equipped with a multi spring thin film actuator, which has a compact structure and high output force. Suitable for controlling high temperature and low temperature high-pressure fluids
Valve body
Type: Straight through double seat cast ball valve
Nominal diameter: 20, 25, 40, 50, 65, 80, 100, 150, 200mm
Nominal pressure: ANSI 125、150、300、600 JIS 10、16、20、30、40K
PN1.6、4.0、6.4MPa
Connection type: flange connection: FF、RF、RJ、LG、 Groove type, embedded type
Flange standards: JIS B2201-1984, ANSI B16.5-1981, GB/T9112-9124-2000, etc
Welding connection: embedded welding SW
Materials: cast steel (ZG230-450), cast stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti, ZG00Cr18Ni12Mo2Ti), titanium, etc
Upper valve cover: room temperature type (P): -17~+230 ℃
Elongation Type I (E1): -45~-17 ℃+230~+566 ℃
Elongation Type II (E2I): -100~-45 ℃
Extension type II (E2W): -196~-100 ℃
Note: The working temperature should not exceed the allowable range of various materials.
Cover type: bolt compression type
Packing: V-shaped PTFE packing, PTFE impregnated asbestos packing, asbestos braided packing, graphite packing
Valve components
Valve core type: single seat sleeve plunger valve core
Flow characteristics: equal percentage characteristics (%) and linear characteristics (L), refer to the flow characteristic curve chart
Sleeve form: Separate sleeve
Materials: Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti, 17-4PH, 9Cr18, 316L), stainless steel overlay with Stellite alloy, titanium, and corrosion-resistant alloys for actuators
Type: LHA multi spring diaphragm actuator, LVA5 single spring diaphragm actuator, LVA6 single acting cylinder piston actuator, LVP double acting cylinder piston actuator
Diaphragm material: Ethylene propylene rubber with nylon cloth, Nitrile rubber with nylon cloth
Spring range: 20-100, 80-240 kPa (LHA, LVA5 type), 190-350, 190-400 kPa (LVA6 type)
Gas supply pressure: 140-400kPa (LHA type), 140-280kPa (LVA5 type)
400-500kPa (LVA6 type), 300-500kPa (LVP type)
Gas source interface: Rc1/4”
Environmental temperature:- 30~+70℃
Valve action type: using positive or negative acting actuators to achieve gas closed or gas open valve operation
Attachments: Positioner, air filter pressure reducer, holding valve, travel switch, valve position transmitter, solenoid valve, handwheel mechanism, etc
performance
Leakage rate: Metal valve seat: less than 0.01% of the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Soft seat: 10-7 less than the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Return difference: with locator: less than 1% of the full stroke,
Without locator: less than 3% of full stroke (LHA1 type less than 5% of full stroke)
Basic error: with locator: less than ± 1% of the full stroke,
Without locator: less than ± 5% of the full stroke
Note: Standard V-shaped polytetrafluoroethylene packing is used
Adjustable range: 50:1 (0.25 Cv/14) or 30:1 (CV/0.16)
Cv value and travel distance
I. High capacity valve core
Nominal diameter (mm) |
40 |
50 |
65 |
80 |
100 |
150 |
200 |
|
Valve seat diameter (mm) |
40 |
50 |
65 |
80 |
100 |
150 |
200 |
|
Rated Cv value |
Equal percentage characteristic |
36 |
60 |
100 |
140 |
220 |
420 |
820 |
linear characteristic |
40 |
75 |
110 |
150 |
240 |
435 |
850 |
|
Rated stroke (mm) |
25 |
38 |
50 |
75 |
II. High precision flow characteristic valve core
Nominal Diameter |
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||||||||||||||
Valve seat diameter |
25 |
32 |
40 |
32 |
40 |
50 |
40 |
50 |
65 |
50 |
65 |
80 |
65 |
80 |
100 |
100 |
125 |
150 |
125 |
150 |
200 |
Rated Cv value |
11 |
17 |
24 |
17 |
24 |
44 |
24 |
44 |
68 |
44 |
68 |
99 |
68 |
99 |
175 |
175 |
275 |
360 |
275 |
360 |
650 |
rated travel |
25 |
38 |
50 |
75 |
Allowable pressure difference
Ⅰ. Metal seat
A. Gas closed valve 100KPa
actuator |
air supply pressure |
Spring range |
positioner |
Allowable pressure difference |
||||||
Nominal Diameter |
||||||||||
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||||
LHA1D |
1.4 |
0.2~1.0 |
with or without |
5.1 |
4.0 |
- |
- |
- |
- |
- |
1.6 |
0.2~1.0 |
have |
25 |
19 |
- |
- |
- |
- |
- |
|
4.0 |
0.8~2.4 |
have |
40 |
40 |
- |
- |
- |
- |
- |
|
76 |
59 |
|||||||||
LHA2D |
1.4 |
0.2~1.0 |
with or without |
9.9 |
7.7 |
6.6 |
5.4 |
4.2 |
- |
- |
1.6 |
0.2~1.0 |
have |
40 |
38 |
32.9 |
27.4 |
20.8 |
- |
- |
|
49.2 |
||||||||||
4.0 |
0.8~2.4 |
have |
40 |
40 |
40 |
40 |
40 |
- |
- |
|
100 |
100 |
98.7 |
82.3 |
62.8 |
||||||
LHA3D |
1.4 |
0.2~1.0 |
with or without |
17.5 |
13.7 |
11.7 |
9.7 |
7.4 |
5.2 |
- |
1.6 |
0.2~1.0 |
have |
40 |
40 |
40 |
40 |
37 |
26.1 |
- |
|
87 |
67 |
58 |
48.7 |
|||||||
4.0 |
0.8~2.4 |
have |
40 |
40 |
40 |
40 |
40 |
40 |
- |
|
100 |
100 |
100 |
100 |
100 |
78.6 |
|||||
LHA4D |
1.4 |
0.2~1.0 |
with or without |
- |
- |
20.2 |
16.7 |
12.8 |
9.0 |
7.4 |
1.6 |
0.2~1.0 |
have |
- |
- |
40 |
40 |
40 |
40 |
37 |
|
100 |
83.9 |
63.6 |
45 |
|||||||
4.0 |
0.8~2.4 |
have |
- |
- |
40 |
40 |
40 |
40 |
40 |
|
100 |
100 |
100 |
100 |
100 |
B. Gas open valve 100KPa
actuator |
air supply pressure |
Spring range |
positioner |
Allowable pressure difference |
||||||
Nominal Diameter |
||||||||||
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||||
LHA1R |
1.4 |
0.2~1.0 |
with or without |
5.1 |
4.0 |
- |
- |
- |
- |
- |
2.8 |
0.8~2.4 |
have |
36 |
27 |
- |
- |
- |
- |
- |
|
LHA2R |
1.4 |
0.2~1.0 |
with or without |
9.9 |
7.7 |
6.6 |
5.4 |
4.2 |
- |
- |
2.8 |
0.8~2.4 |
have |
40 |
40 |
40 |
38.4 |
29.3 |
- |
- |
|
68.1 |
53.9 |
46 |
||||||||
LHA3R |
1.4 |
0.2~1.0 |
with or without |
17.5 |
13.7 |
11.7 |
9.7 |
7.4 |
5.2 |
- |
2.8 |
0.8~2.4 |
have |
40 |
40 |
40 |
40 |
40 |
36.7 |
- |
|
100 |
95.7 |
81.7 |
68 |
51.8 |
||||||
LHA4R |
1.4 |
0.2~1.0 |
with or without |
- |
- |
20.2 |
16.7 |
12.8 |
9.0 |
7.4 |
2.8 |
0.8~2.4 |
have |
- |
- |
40 |
40 |
40 |
40 |
40 |
|
100 |
100 |
89.7 |
63 |
51 |
||||||
LVA5R |
1.4 |
0.2~1.0 |
with or without |
- |
- |
- |
- |
17.5 |
12.3 |
10.2 |
1.4 |
0.4~1.2 |
with or without |
- |
- |
- |
- |
40 |
37 |
30.7 |
|
52 |
||||||||||
2.8 |
0.8~2.4 |
have |
- |
- |
- |
- |
40 |
40 |
40 |
|
100 |
80 |
70 |
||||||||
LVA6R |
4.0 |
1.9~3.5 |
have |
- |
- |
- |
- |
40 |
- |
- |
100 |
||||||||||
5.0 |
1.9~4.0 |
have |
- |
- |
- |
- |
- |
40 |
- |
|
100 |
1.The maximum allowable pressure difference shall not exceed the maximum working pressure specified in ANSI B16.34 or JIS B2201 standards.
The upper number in the same compartment represents the allowable pressure difference when the valve is normally open, and the lower number represents the allowable pressure difference when the valve is fully closed.
3. The numbers in the black box indicate the standard specification actuator II for the valve Soft valve seat A Gas closed valve 100KPa
actuator |
air supply pressure |
Spring range |
positioner |
Allowable pressure difference |
||||||
Nominal Diameter |
||||||||||
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||||
LHA1D |
1.4 |
0.2~1.0 |
with or without |
3.6* |
2.8* |
- |
- |
- |
- |
- |
1.6 |
0.2~1.0 |
have |
17 |
13 |
- |
- |
- |
- |
- |
|
4.0 |
0.8~2.4 |
have |
30 |
30 |
- |
- |
- |
- |
- |
|
LHA2D |
1.4 |
0.2~1.0 |
with or without |
6.9* |
5.4* |
4.6* |
3.8* |
2.9* |
- |
- |
1.6 |
0.2~1.0 |
have |
30 |
26.6 |
23.0 |
19.2 |
14.6 |
- |
- |
|
4.0 |
0.8~2.4 |
have |
30 |
30 |
30 |
30 |
30 |
- |
- |
|
LHA3D |
1.4 |
0.2~1.0 |
with or without |
12.3* |
9.6* |
8.2* |
6.8* |
5.2* |
3.6* |
- |
1.6 |
0.2~1.0 |
have |
30 |
30 |
30 |
30 |
25.9 |
18.3 |
- |
|
4.0 |
0.8~2.4 |
have |
30 |
30 |
30 |
30 |
30 |
30 |
- |
|
LHA4D |
1.4 |
0.2~1.0 |
with or without |
- |
- |
14.1* |
11.7* |
9.0* |
6.3* |
5.2* |
1.6 |
0.2~1.0 |
have |
- |
- |
30 |
30 |
30 |
30 |
25.9 |
|
4.0 |
0.8~2.4 |
have |
- |
- |
30 |
30 |
30 |
30 |
30 |
B. Gas open valve 100KPa
actuator |
air supply pressure |
Spring range |
positioner |
Allowable pressure difference |
||||||
Nominal Diameter |
||||||||||
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||||
LHA1R |
1.4 |
0.2~1.0 |
with or without |
3.6* |
2.8* |
- |
- |
- |
- |
- |
2.8 |
0.8~2.4 |
have |
25 |
19 |
- |
- |
- |
- |
- |
|
LHA2R |
1.4 |
0.2~1.0 |
with or without |
6.9* |
5.4* |
4.6* |
3.8* |
2.9* |
- |
- |
2.8 |
0.8~2.4 |
have |
30 |
30 |
30 |
26.9 |
20.5 |
- |
- |
|
LHA3R |
1.4 |
0.2~1.0 |
with or without |
12.3* |
9.6* |
8.2* |
6.8* |
5.2* |
3.6* |
- |
2.8 |
0.8~2.4 |
have |
30 |
30 |
30 |
30 |
30 |
30 |
- |
|
LHA4R |
1.4 |
0.2~1.0 |
with or without |
- |
- |
14.1* |
11.7* |
9.0* |
6.3* |
5.2* |
2.8 |
0.8~2.4 |
have |
- |
- |
30 |
30 |
30 |
30 |
30 |
Note:1. The maximum allowable pressure difference shall not exceed the maximum working pressure specified in ANSI B16.34 or JIS B2201 standards.
2. Leakage rate with * valve≤ 10-4, compliant with ANSI B16.04 Level IV standard, without valve leakage rate; 10-7, compliant with ANSI B16.04-1976 Grade VI.
3. The numbers in the black box indicate the standard specification actuator for the valve. Flange distance and external dimensions Flange distance mm
Nominal Diameter |
A |
|||||||
ANSI 125 FF |
JIS 16K RF |
ANSI 300 RF |
ANSI 600RF |
JIS 16K |
JIS 20 |
JIS 30K |
JIS 40K |
|
40 |
222 |
231 |
235 |
251 |
235 |
236 |
248 |
251 |
50 |
254 |
263 |
267 |
286 |
265 |
267 |
276 |
286 |
65 |
276 |
288 |
292 |
311 |
290 |
292 |
303 |
311 |
80 |
298 |
313 |
317 |
337 |
310 |
317 |
326 |
337 |
100 |
352 |
364 |
368 |
394 |
360 |
368 |
379 |
394 |
150 |
451 |
465 |
473 |
508 |
475 |
473 |
486 |
508 |
200 |
543 |
560 |
568 |
610 |
570 |
568 |
580 |
610 |
Nominal Diameter |
A |
|||||||
ANSI 150 |
ANSI 300 |
ANSI 600 |
ANSI 300 |
ANSI 600 LG |
ANSI 150 |
ANSI 150、600 |
||
40 |
235 |
248 |
251 |
244 |
248 |
251 |
251 |
|
50 |
267 |
283 |
289 |
276 |
283 |
286 |
286 |
|
65 |
289 |
308 |
314 |
302 |
308 |
311 |
311 |
|
80 |
311 |
333 |
340 |
327 |
333 |
337 |
337 |
|
100 |
365 |
384 |
397 |
378 |
391 |
394 |
394 |
|
150 |
464 |
489 |
511 |
483 |
505 |
473 |
508 |
|
200 |
556 |
584 |
613 |
578 |
606 |
568 |
610 |
Note: The flange spacing complies with the IEC534-3 standard.
Ordering Notice: Please fill in the "Specification Sheet" or indicate the following content when placing an order:
1. Product model
2. Nominal pressure
3. Nominal diameter and rated flow coefficient Kv
4. Signal pressure and spring range
5. Traffic characteristics
6. Valve switching method
7. Working temperature range of the medium
8. Valve body and valve core materials
9. Is there an attachment? Please specify the attachment model
10. Are there any other special requirements