HCB type pneumatic cooling regulating valveIt is a pressure balanced regulating valve, with an S-shaped fluid channel inside the valve and a guiding wing to improve the smooth flow of fluid around the sleeve. Its advantages are low pressure drop loss, high flow rate, and wide adjustable range. The flow characteristic curve has high accuracy and good dynamic stability. Low noise, minimal cavitation and corrosion, good dynamic stability of regulating valve, low noise, air defense, suitable for controlling high-pressure differential fluids at various temperatures. Equipped with LHA multi spring thin film actuator or electric actuator, it has a compact structure and high output force. The product complies with GB/T4213-92..
Type: Straight through double seat cast ball valve
Nominal diameter: 20, 25, 40, 50, 65, 80, 100, 150, 200mm
Nominal pressure: ANSI 125、150、300、600 JIS 10、16、20、30、40K
PN1.6、4.0、6.4MPa
Connection type: flange connection: FF、RF、RJ、LG、 Groove type, embedded type
Flange standards: JIS B2201-1984, ANSI B16.5-1981, GB/T9112-9124-2000, etc
Welding connection: embedded welding SW
Materials: cast steel (ZG230-450), cast stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti, ZG00Cr18Ni12Mo2Ti), titanium, etc
Upper valve cover: room temperature type (P): -17~+230 ℃
Elongation Type I (E1): -45~-17 ℃+230~+566 ℃
Elongation Type II (E2I): -100~-45 ℃
Extension type II (E2W): -196~-100 ℃
Note: The working temperature should not exceed the allowable range of various materials.
Cover type: bolt compression type
Packing: V-shaped PTFE packing, PTFE impregnated asbestos packing, asbestos braided packing, graphite packing
Valve components
Valve core type: single seat sleeve plunger valve core
Flow characteristics: equal percentage characteristics (%) and linear characteristics (L), refer to the flow characteristic curve chart
Sleeve form: Separate sleeve
Materials: Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti, 17-4PH, 9Cr18, 316L), stainless steel overlay with Stellite alloy, titanium, and corrosion-resistant alloys, etc
Type: LHA multi spring diaphragm actuator, LVA5 single spring diaphragm actuator, LVA6 single acting cylinder piston actuator, LVP double acting cylinder piston actuator
Diaphragm material: Ethylene propylene rubber with nylon cloth, Nitrile rubber with nylon cloth
Spring range: 20-100, 80-240 kPa (LHA, LVA5 type), 190-350, 190-400 kPa (LVA6 type)
Gas supply pressure: 140-400kPa (LHA type), 140-280kPa (LVA5 type)
400-500kPa (LVA6 type), 300-500kPa (LVP type)
Gas source interface: Rc1/4”
Environmental temperature:- 30~+70℃
Valve action type: using positive or negative acting actuators to achieve gas closed or gas open valve operation
Attachments: Positioner, air filter pressure reducer, holding valve, travel switch, valve position transmitter, solenoid valve, handwheel mechanism, etc
performance
Leakage rate: Metal valve seat: less than 0.01% of the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Soft seat: 10-7 less than the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Return difference: with locator: less than 1% of the full stroke,
Without locator: less than 3% of full stroke (LHA1 type less than 5% of full stroke)
Basic error: with locator: less than ± 1% of the full stroke,
Without locator: less than ± 5% of the full stroke
Note: Standard V-shaped polytetrafluoroethylene packing is used
Adjustable range: 50:1 (0.25 ≤ Cv ≤ 14) or 30:1 (CV ≤ 0.16)
Cv value and travel distance
High capacity valve core
Nominal diameter (mm)
|
40
|
50
|
65
|
80
|
100
|
150
|
200
|
|
Valve seat diameter (mm)
|
40
|
50
|
65
|
80
|
100
|
150
|
200
|
|
Rated Cv value
|
Equal percentage characteristic
|
36
|
60
|
100
|
140
|
220
|
420
|
820
|
linear characteristic
|
40
|
75
|
110
|
150
|
240
|
435
|
850
|
|
Rated stroke (mm)
|
25
|
38
|
50
|
75
|
High precision flow characteristic valve core
Nominal Diameter
|
40
|
50
|
65
|
80
|
100
|
150
|
200
|
||||||||||||||
Valve seat diameter
|
25
|
32
|
40
|
32
|
40
|
50
|
40
|
50
|
65
|
50
|
65
|
80
|
65
|
80
|
100
|
100
|
125
|
150
|
125
|
150
|
200
|
Rated Cv value
|
11
|
17
|
24
|
17
|
24
|
44
|
24
|
44
|
68
|
44
|
68
|
99
|
68
|
99
|
175
|
175
|
275
|
360
|
275
|
360
|
650
|
rated travel
|
25
|
38
|
50
|
75
|
Allowable pressure difference
A. Angry? Closed valve 100Kpa
actuator
|
air supply pressure
|
Spring range
|
positioner
|
Allowable pressure difference
|
||||||
Nominal Diameter
|
||||||||||
40
|
50
|
65
|
80
|
100
|
150
|
200
|
||||
LHA1D
|
1.4
|
0.2~1.0
|
with or without
|
5.1
|
4.0
|
-
|
-
|
-
|
-
|
-
|
1.6
|
0.2~1.0
|
have
|
25
|
19
|
-
|
-
|
-
|
-
|
-
|
|
4.0
|
0.8~2.4
|
have
|
40
|
40
|
-
|
-
|
-
|
-
|
-
|
|
76
|
59
|
|||||||||
LHA2D
|
1.4
|
0.2~1.0
|
with or without
|
9.9
|
7.7
|
6.6
|
5.4
|
4.2
|
-
|
-
|
1.6
|
0.2~1.0
|
have
|
40
|
38
|
32.9
|
27.4
|
20.8
|
-
|
-
|
|
49.2
|
||||||||||
4.0
|
0.8~2.4
|
have
|
40
|
40
|
40
|
40
|
40
|
-
|
-
|
|
100
|
100
|
98.7
|
82.3
|
62.8
|
||||||
LHA3D
|
1.4
|
0.2~1.0
|
with or without
|
17.5
|
13.7
|
11.7
|
9.7
|
7.4
|
5.2
|
-
|
1.6
|
0.2~1.0
|
have
|
40
|
40
|
40
|
40
|
37
|
26.1
|
-
|
|
87
|
67
|
58
|
48.7
|
|||||||
4.0
|
0.8~2.4
|
have
|
40
|
40
|
40
|
40
|
40
|
40
|
-
|
|
100
|
100
|
100
|
100
|
100
|
78.6
|
|||||
LHA4D
|
1.4
|
0.2~1.0
|
with or without
|
-
|
-
|
20.2
|
16.7
|
12.8
|
9.0
|
7.4
|
1.6
|
0.2~1.0
|
have
|
-
|
-
|
40
|
40
|
40
|
40
|
37
|
|
100
|
83.9
|
63.6
|
45
|
|||||||
4.0
|
0.8~2.4
|
have
|
-
|
-
|
40
|
40
|
40
|
40
|
40
|
|
100
|
100
|
100
|
100
|
100
|
actuator
|
air supply pressure
|
Spring range
|
positioner
|
Allowable pressure difference
|
||||||
Nominal Diameter
|
||||||||||
40
|
50
|
65
|
80
|
100
|
150
|
200
|
||||
LHA1R
|
1.4
|
0.2~1.0
|
with or without
|
5.1
|
4.0
|
-
|
-
|
-
|
-
|
-
|
2.8
|
0.8~2.4
|
have
|
36
|
27
|
-
|
-
|
-
|
-
|
-
|
|
LHA2R
|
1.4
|
0.2~1.0
|
with or without
|
9.9
|
7.7
|
6.6
|
5.4
|
4.2
|
-
|
-
|
2.8
|
0.8~2.4
|
have
|
40
|
40
|
40
|
38.4
|
29.3
|
-
|
-
|
|
68.1
|
53.9
|
46
|
||||||||
LHA3R
|
1.4
|
0.2~1.0
|
with or without
|
17.5
|
13.7
|
11.7
|
9.7
|
7.4
|
5.2
|
-
|
2.8
|
0.8~2.4
|
have
|
40
|
40
|
40
|
40
|
40
|
36.7
|
-
|
|
100
|
95.7
|
81.7
|
68
|
51.8
|
||||||
LHA4R
|
1.4
|
0.2~1.0
|
with or without
|
-
|
-
|
20.2
|
16.7
|
12.8
|
9.0
|
7.4
|
2.8
|
0.8~2.4
|
have
|
-
|
-
|
40
|
40
|
40
|
40
|
40
|
|
100
|
100
|
89.7
|
63
|
51
|
||||||
LVA5R
|
1.4
|
0.2~1.0
|
with or without
|
-
|
-
|
-
|
-
|
17.5
|
12.3
|
10.2
|
1.4
|
0.4~1.2
|
with or without
|
-
|
-
|
-
|
-
|
40
|
37
|
30.7
|
|
52
|
||||||||||
2.8
|
0.8~2.4
|
have
|
-
|
-
|
-
|
-
|
40
|
40
|
40
|
|
100
|
80
|
70
|
||||||||
LVA6R
|
4.0
|
1.9~3.5
|
have
|
-
|
-
|
-
|
-
|
40
|
-
|
-
|
100
|
||||||||||
5.0
|
1.9~4.0
|
have
|
-
|
-
|
-
|
-
|
-
|
40
|
-
|
|
100
|
1. The maximum allowable pressure difference shall not exceed the maximum working pressure specified in ANSI B16.34 or JIS B2201 standards.
The upper number in the same compartment represents the allowable pressure difference when the valve is normally open, and the lower number represents the allowable pressure difference when the valve is fully closed.
3. The numbers in the black box indicate the standard specification actuator for the valve
actuator
|
air supply pressure
|
Spring range
|
positioner
|
Allowable pressure difference
|
||||||
Nominal Diameter
|
||||||||||
40
|
50
|
65
|
80
|
100
|
150
|
200
|
||||
LHA1D
|
1.4
|
0.2~1.0
|
with or without
|
3.6*
|
2.8*
|
-
|
-
|
-
|
-
|
-
|
1.6
|
0.2~1.0
|
have
|
17
|
13
|
-
|
-
|
-
|
-
|
-
|
|
4.0
|
0.8~2.4
|
have
|
30
|
30
|
-
|
-
|
-
|
-
|
-
|
|
LHA2D
|
1.4
|
0.2~1.0
|
with or without
|
6.9*
|
5.4*
|
4.6*
|
3.8*
|
2.9*
|
-
|
-
|
1.6
|
0.2~1.0
|
have
|
30
|
26.6
|
23.0
|
19.2
|
14.6
|
-
|
-
|
|
4.0
|
0.8~2.4
|
have
|
30
|
30
|
30
|
30
|
30
|
-
|
-
|
|
LHA3D
|
1.4
|
0.2~1.0
|
with or without
|
12.3*
|
9.6*
|
8.2*
|
6.8*
|
5.2*
|
3.6*
|
-
|
1.6
|
0.2~1.0
|
have
|
30
|
30
|
30
|
30
|
25.9
|
18.3
|
-
|
|
4.0
|
0.8~2.4
|
have
|
30
|
30
|
30
|
30
|
30
|
30
|
-
|
|
LHA4D
|
1.4
|
0.2~1.0
|
with or without
|
-
|
-
|
14.1*
|
11.7*
|
9.0*
|
6.3*
|
5.2*
|
1.6
|
0.2~1.0
|
have
|
-
|
-
|
30
|
30
|
30
|
30
|
25.9
|
|
4.0
|
0.8~2.4
|
have
|
-
|
-
|
30
|
30
|
30
|
30
|
30
|
actuator
|
air supply pressure
|
Spring range
|
positioner
|
Allowable pressure difference
|
||||||
Nominal Diameter
|
||||||||||
40
|
50
|
65
|
80
|
100
|
150
|
200
|
||||
LHA1R
|
1.4
|
0.2~1.0
|
with or without
|
3.6*
|
2.8*
|
-
|
-
|
-
|
-
|
-
|
2.8
|
0.8~2.4
|
have
|
25
|
19
|
-
|
-
|
-
|
-
|
-
|
|
LHA2R
|
1.4
|
0.2~1.0
|
with or without
|
6.9*
|
5.4*
|
4.6*
|
3.8*
|
2.9*
|
-
|
-
|
2.8
|
0.8~2.4
|
have
|
30
|
30
|
30
|
26.9
|
20.5
|
-
|
-
|
|
LHA3R
|
1.4
|
0.2~1.0
|
with or without
|
12.3*
|
9.6*
|
8.2*
|
6.8*
|
5.2*
|
3.6*
|
-
|
2.8
|
0.8~2.4
|
have
|
30
|
30
|
30
|
30
|
30
|
30
|
-
|
|
LHA4R
|
1.4
|
0.2~1.0
|
with or without
|
-
|
-
|
14.1*
|
11.7*
|
9.0*
|
6.3*
|
5.2*
|
2.8
|
0.8~2.4
|
have
|
-
|
-
|
30
|
30
|
30
|
30
|
30
|
1. The maximum allowable pressure difference shall not exceed the maximum working pressure specified in ANSI B16.34 or JIS B2201 standards.
2. The leakage rate with * valve is ≤ 10-4, in accordance with the standard ANSI B16.04 Level IV, and the leakage rate without * valve is ≤ 10-7, in accordance with the standard ANSI B16.04-1976 Level VI.
3. The numbers in the black box indicate the standard specification actuator for the valve.
Nominal Diameter
|
A
|
||||||||||
ANSI 125 FF
ANSI 150 RF JIS 10K FF RF PN1.6 |
JIS 16K RF
|
ANSI 300 RF
JIS 20K RF JIS 30K RF PN4.0 |
ANSI 600RF
JIS 40K RF PN6.4 |
JIS 16K
Trench Embedded type |
JIS 20
Trench Embedded type |
JIS 30K
Trench Embedded type |
JIS 40K
Trench Embedded type |
||||
40
|
222
|
231
|
235
|
251
|
235
|
236
|
248
|
251
|
|||
50
|
254
|
263
|
267
|
286
|
265
|
267
|
276
|
286
|
|||
65
|
276
|
288
|
292
|
311
|
290
|
292
|
303
|
311
|
|||
80
|
298
|
313
|
317
|
337
|
310
|
317
|
326
|
337
|
|||
100
|
352
|
364
|
368
|
394
|
360
|
368
|
379
|
394
|
|||
150
|
451
|
465
|
473
|
508
|
475
|
473
|
486
|
508
|
|||
200
|
543
|
560
|
568
|
610
|
570
|
568
|
580
|
610
|
|||
Nominal Diameter
|
A
|
||||||||||
ANSI 150
RJ |
ANSI 300
RJ |
ANSI 600
RJ |
ANSI 300
LG |
ANSI 600 LG
|
ANSI 150
SW、BW |
ANSI 150、600
SW、BW |
|||||
40
|
235
|
248
|
251
|
244
|
248
|
251
|
251
|
||||
50
|
267
|
283
|
289
|
276
|
283
|
286
|
286
|
||||
65
|
289
|
308
|
314
|
302
|
308
|
311
|
311
|
||||
80
|
311
|
333
|
340
|
327
|
333
|
337
|
337
|
||||
100
|
365
|
384
|
397
|
378
|
391
|
394
|
394
|
||||
150
|
464
|
489
|
511
|
483
|
505
|
473
|
508
|
||||
200
|
556
|
584
|
613
|
578
|
606
|
568
|
610
|
The flange distance complies with the IEC534-3 standard
Ordering Notice: Please fill in the "Specification Sheet" or indicate the following content when placing an order:
1. Product model
2. Nominal pressure
3. Nominal diameter and rated flow coefficient Kv
4. Signal pressure and spring range
5. Traffic characteristics
6. Valve switching method
7. Working temperature range of the medium
8. Valve body and valve core materials
9. Is there an attachment? Please specify the attachment model
10. Are there any other special requirements