HCFA corrosion-resistant and wear-resistant clamp pump
Product details

1 Product Structure


2 Application scope

The HCFA type corrosion-resistant and wear-resistant clamp plate centrifugal pump from Qianggong Pump Industry has a wide range of applications.

Transport medium: with a solid content below 40% (volume ratio) and a temperature below 150 ℃ (due to differences in materials), the medium must not undergo chemical reactions with the material of the pump flow.

When the density of the pumped medium is greater than 1.2 or the viscosity is greater than water, a motor with correspondingly higher output power needs to be used.

Specific material selection and matching motor power can be consulted with our technical department personnel.

Chemical industryTransportation and circulation of various acids, alkalis, salts, organic chemicals, and corrosive slurries.

Acid circulation pumps and waste acid pumps in the pickling industry, including stainless steel mixed acid pickling (hydrofluoric acid mixed with nitric acid, hydrofluoric acid mixed with sulfuric acid, and others), carbon steel plate hydrochloric acid pickling, titanium plate and other metal plate pickling.

Acid regeneration industryWaste acid conveying pump, acid supply pump, and acid circulation pump in the middle.

Oxidation industryThe oxidation circulation pump, sealing circulation pump, coloring circulation pump, and soup washing circulation pump used for aluminum oxidation.

Desulfurization industryThe slurry circulation pump used for ammonia desulfurization, magnesium oxide desulfurization, etc.

Other media containing corrosive and certain abrasives.

Meaning of Model 3

Example: HCFA200—150—315

HCFA - Corrosion resistant and wear-resistant clamp plate centrifugal pump

200- Pump inlet diameter (mm)

150- Pump outlet diameter (mm)

315- nominal diameter of impeller (mm)

4 Technical data

4.1 Environmental temperature

The maximum temperature is+40 ℃

If the ambient temperature exceeds 40 ℃, or when the installation height of the motor exceeds 1000 meters above sea level, the output power of the motor will decrease due to the decrease in air density and the corresponding lower air cooling effect. In this case, a motor with higher output power must be selected. If the actual operating environmental conditions of the motor exceed the above standards, its actual effective output power can be calculated and corrected according to the following formula:

Actual effective output power=rated output power x temperature coefficient x altitude coefficient

Environmental temperature (℃)

temperature coefficient

Environmental altitude (m)

Altitude coefficient

30

1.06

1000

1.0

35

1.03

1500

0.98

40

1.00

2000

0.94

45

0.97

2500

0.91

50

0.93

3000

0.87

55

0.88

3500

0.82

60

0.82

4000

0.77

*When the actual effective output power of the calculation result is greater than the rated power, the standard motor should be used with reduced load, or special design and manufacturing should be carried out by the motor manufacturer in consultation with the motor manufacturer to meet the on-site operation requirements.

4.2 Medium temperature

HCFA acid resistant and wear-resistant pump is suitable for media ranging from -20 ℃ to 150 ℃.

Pump overcurrent material

Minimum operating temperature

maximum service temperature

UHMWPE

-20℃

80℃

PPH

-20℃

110℃

PFA

-20℃

150℃

*Other materials can be customized according to working conditions

4.3 Minimum Import Pressure

Minimum inlet pressure calculation method:

H= Pb×10.2-NPSH-Hf-Hv-Hs

Among them:

Pb=atmospheric pressure value shown on the barometer (atmospheric pressure can be preset to 0.1 MPa).

In a closed system, Pb is the system pressure in the barometer.

NSPH=cavitation allowance (see pump performance parameter table)

Hf=Friction loss of liquid in the pump suction pipeline

Hv=vaporization pressure

Hs=safety margin (minimum taken as 0.5 meters)

If H is a positive value, it means that the height at which the pump can suction on the suction side is H meters;

If H is calculated as a negative value, the pump inlet must have a pressure of at least H meters high, and during operation, the pressure must be equal to the calculated H.

4.4 Maximum import pressure

The maximum inlet pressure of the pump plus the head of the pump when the valve is closed shall not exceed the maximum allowable design pressure of the pump.

4.5 Minimum flow rate

When the flow rate of the pump is close to zero during operation, almost all of the energy of the pump is transferred to the pumping medium in the form of thermal energy. The liquid will be heated until it vaporizes, which will cause serious damage to the impeller and ultimately damage the pump. The mechanical seal components will also be damaged.

In engineering, for the sake of simplicity, actual empirical data can also be used to determine the minimum continuous heat flow rate of centrifugal pumps. Approximately 30% to 40% of the rated flow rate is used for the minimum continuous heat flow rate. A bypass pipe can be installed on the pipeline between the pump outlet flange and the outlet valve to return to the suction source, and a throttle valve for regulating the flow rate can be installed on the bypass pipe. In this way, the flow rate can be adjusted when the outlet valve is open (but this method reduces the efficiency of the pump).

4.6 Electrical Data

Please refer to the motor nameplate and motor manual for details.

4.7 Noise level

Complies with GB/T 29529-2013 "Methods for measuring and evaluating pump noise"

5 Performance parameter table

model

internet traffic

m3/h

lift

m

rotational speed

r/min

Equipped with power

kw

efficiency

%

Must have cavitation allowance

m

HCFA32-25-160

3.2

32

2900

3

39

5

HCFA32-25-160

1.6

8

1450

0.75

35

5

HCFA40-32-125

6.3

20

2900

3

52

5

HCFA40-32-125

3.2

5

1450

0.75

46

5

HCFA40-32-160

6.3

32

2900

4

47

5

HCFA40-32-160

3.2

8

1450

1.1

42

5

HCFA40-32-200

6.3

50

2900

7.5

38

5

HCFA40-32-200

3.2

12.5

1450

1.5

38

5

HCFA40-32-250

6.3

80

2900

15

32

5

HCFA40-32-250

3.2

20

1450

2.2

35

5

HCFA50-32-125

12.5

20

2900

4

51

3.8

HCFA50-32-125

6.3

5

1450

0.75

45

3.5

HCFA50-32-160

12.5

32

2900

5.5

46

3.8

HCFA50-32-160

6.3

8

1450

1.1

40

3.5

HCFA50-32-200

12.5

50

2900

11

39

3.8

HCFA50-32-200

6.3

12.5

1450

2.2

33

3.5

HCFA50-32-250

12.5

80

2900

18.5

33

3.8

HCFA50-32-250

6.3

20

1450

3

27

3.5

HCFA65-50-125

25

20

2900

4

62

3.8

HCFA65-50-125

12.5

5

1450

0.75

55

3.5

HCFA65-50-160

25

32

2900

7.5

57

3.8

HCFA65-50-160

12.5

8

1450

1.5

51

3.5

HCFA65-50-200

25

50

2900

15

52

3.8

HCFA65-50-200

12.5

12.5

1450

2.2

46

3.5

HCFA65-40-250

25

80

2900

22

46

3.8

HCFA65-40-250

12.5

20

1450

4

39

3.5

HCFA65-40-315

25

125

2900

37

39

3.8

HCFA65-40-315

12.5

32

1450

7.5

33

3.5

HCFA80-65-125

50

20

2900

7.5

69

4

HCFA80-65-125

25

5

1450

1.5

64

3.8

HCFA80-65-160

50

32

2900

15

67

4

HCFA80-65-160

25

8

1450

2.2

62

3.8

HCFA80-50-200

50

50

2900

18.5

63

4

HCFA80-50-200

25

12.5

1450

3

57

3.8

HCFA80-50-250

50

80

2900

37

57

4

HCFA80-50-250

25

20

1450

5.5

53

3.8

HCFA80-50-315

25

32

1450

11

42

3.8

HCFA80-50-400

25

50

1450

18.5

24

3.8

HCFA100-80-125

100

20

2900

15

77

4.5

HCFA100-80-125

50

5

1450

2.2

74

4

HCFA100-80-160

100

32

2900

18.5

73

4.5

HCFA100-80-160

50

8

1450

3

69

4

HCFA100-65-200

100

50

2900

37

72

4.5

HCFA100-65-200

50

12.5

1450

5.5

68

4

HCFA100-65-250

100

80

2900

55

68

4.5

HCFA100-65-250

50

20

1450

7.5

65

4

HCFA100-65-315

50

32

1450

15

58

4

HCFA100-65-400

50

50

1450

30

29

4

HCFA125-100-200

200

50

2900

55

77

4.8

HCFA125-100-200

100

12.5

1450

11

73

4.5

HCFA125-100-250

100

20

1450

15

72

4.5

HCFA125-100-315

100

32

1450

22

68

4.5

HCFA125-100-400

100

50

1450

37

60

4.5

HCFA150-125-250

200

20

1450

22

77

4.8

HCFA150-125-315

200

32

1450

37

75

4.8

HCFA150-125-400

200

50

1450

75

70

4.8

HCFA200-150-250

400

20

1450

45

81

5

HCFA200-150-315

400

32

1450

75

79

5

HCFA200-150-400

400

50

1450

110

78

5

HCFA250-200-400

600

40

1450

132

85

4.8

HCFA250-200-400

400

20

980

37

82

3

HCFA250-200-500

600

70

1450

160

84

4.8

HCFA250-200-500

400

32

980

55

79

4.5

HCFA300-250-400

1200

40

1450

280

85

5

HCFA300-250-400

800

20

980

90

83

5




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!