HFP01SC-L self calibrating soil heat flux plate
HFP01SC-L, Self calibrating soil heat flux plate, very accurate, with self calibration function, suitable for energy balance vorticity covariance and
Product details

overview

HFP01SC measures soil heat flux, typically used in energy balance systems or Bowen ratio flux systems. Each site requires at least 2 soil heat flux sensors to provide sufficient spatial averaging. Stations with non-uniform media may require more sensors

能量平衡安装示例(hfp01与CS616和TCAV一起安装).png

    Product features:

    • Correction of errors caused by differences in thermal conductivity between sensors and surrounding media, temperature fluctuations, and slight sensor instability

    • Compatible with most Campbell Scientific data loggers

    • The Van den Bos Hoeksma self calibration method is used to provide high measurement accuracy

    Technical Description:

    HFP01SC includes a thermopile and a thin film heater. Thermopile is used to measure the temperature gradient across the sensor board. During in-situ field calibration, the heater generates heat flux through the sensor board, and its power is measured by the data collector; The data collector simultaneously measures the response signal of the sensor and calculates to generate a new calibration constant. At the factory, each heat flux plate sensor is calibrated separately to output heat flux.

    Self calibration corrects errors caused by differences in thermal conductivity between the sensor and the surrounding medium, temperature changes, and slight sensor instability.


    Sensor Type

    Thermopile with film heaterThin film thermoelectric stack

    Sensitivity Sensitivity

    50 μV W-1m-2(nominal)

    Nominal resistance

    2 Ω

    Temperature Range

    -30° to +70°C

    Expected Typical Accuracy

    ±3% of reading

    Heater Resistance

    100 Ω (nominal)

    Heater Voltage Input

    9 to 15 Vdc

    Heater Voltage Output

    0 to 2 Vdc

    Duration of Calibration

    ±3 minutes @ 1.5 W (typically performed every 3 to 6 hours)

    Average Power Consumption

    0.02 to 0.04 W

    Plate Diameter

    80 mm (3.15 in.)

    Plate Thickness

    5 mm (0.20 in.)

    Weight

    200 g (7.05 oz) without cable


    HFP01SC-L self calibrating soil heat flux plate. pdf