HI98360 Pure Water Conductivity Meter
HI98360 Pure Water Conductivity Meter, HI98360 Waterproof Multi functional Portable EC/TDS/NaCl/℃ Tester/HI98360 Pure Water Conductivity Meter, HI9836
Product details

HI98360 Pure Water Conductivity Meter

HI98360 Waterproof Multi functional Portable EC/TDS/NaCl/℃ Tester/HI98360 Pure Water Conductivity Meter,HI98360 is Hana's new waterproof multifunctional portable EC/TDS/NaCl/℃ measuring instrument. The instrument can automatically identify the range, and users can choose the appropriate accuracy for EC/TDS measurement based on the sample to be tested. The instrument can store and transmit data to a PC through the RS232 port. Equipped with automatic endpoint judgment and locking function, portable operation, and accurate data.

Technical parameters of HI98360 pure water conductivity meter

Project
Conductivity (EC)
Total Solid Solubility (TDS)
Salinity (NaCl)
Temperature (℃)
measuring range
0.00 to 29.99μS/cm;
30.0 to 299.9μS/cm;
300 to 2999μS/cm;
3.00 to 29.99mS/cm;
30.0 to 200.0 mS/cm
Up to 500.0mS/cm
(Not using temperature compensation function)
Actual conductivity value at that time
0.00 to 14.99ppm
15.0 to 149.9ppm
150 to 1499ppm
1.50 to 4.99ppt
15.0 to 100.0ppt
Up to 400.0ppt
(Actual TDS value without temperature compensation function, conversion factor 0.80)
0.0 to 400.0% 9.9 to 120℃
Resolution
0.01μS/cm
(0.00 to 29.99μS/cm)
0.1μS/cm
(30.0 to 299.9μS/cm)
1μS/cm
(300 to 2999μS/cm)
0.01mS/cm
(3.00 to 29.00ms/cm)
0.1ms/cm
(Above 30.0ms/cm)
0.01ppm
(0.00 to 14.99ppm)
0.1ppm
(15.0 to 149.9ppm)
1ppm
(150 to 1499ppm)
0.01g/l
(1.50 to 14.99g/l)
0.1g/l(15.0g/lc h )
0.1% 0.1℃
accuracy
± 0.5% of the reading
± 0.5% of the reading ± 0.5% of the reading ± 0.4 ℃
Correction
Automatic, with six built-in calibration points for self recognition (841415000, 128808000, and 111800 μ S/cm) Perform a small test in H7037 calibration solution Calibration at 0 ℃ and 50 ℃
temperature calibration
Manual or automatic temperature compensation from 0 to 60 ℃
Temperature compensation coefficient
0.00 to 6.00%/℃ adjustable, factory set to 1.9%/℃
Electrode
HI76309 four ring conductive electrode
TDS conversion factor
Adjustable from 0.40 to 0.80, normal is 0.50
Data Storage
250 sets of samples
Probe
HI76309/1.5 (including 1.5 meters)
Power supply
4×1.5AA
application environment
0 to 50℃; 100%RH

Standard configuration of HI98360 pure water conductivity meter:
HI98360 Pure Water Conductivity Meter Host HI76309/1.5 Four Loop Conductivity Electrode 1.5VAA Battery Four HI7031H Bottles

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!