Beckman Coulter HIAC HRLD Laboratory Liquid Particle Counter | ||
The reliability of the HIAC liquid particle counting HRLD series photomask sensor is second to none in the industry, and it can be applied to various flow rates and high concentration limits, with a wide dynamic range. The HIAC HRLD sensor can be used both online and in batch processing operations, and has high adaptability in almost any application. |
| ![]() |
Liquid particle counter | Advantages of choosing HIAC HRLD series
-Reliability of HIAC
The repeated count is less than 5%, exceeding the calibration standards of ISO11171 particle counting and the requirements of NIST traceability calibration.
-Manage all applications involving any liquids and reporting standards
Water solutions, oil products, and corrosive liquids can be tested on one instrument, supporting ISO4406, NAS1638, as well as user-defined tests that comply with ISOMTD, ACFTD, and ISO11171 particle counting standards. The particle size that can be counted ranges from 1.2um to 600um, and the corresponding sensor can be replaced
-HIAC's Global Services
HIAC HRLD is the mainstay of the industry! The HIACHRLD liquid particle counter has become the industry standard with unparalleled support and service levels, as well as over 25 years of on-site experience.
HIAC HRLD series liquid particle counting sensorapplication area
Examples of common fluid applications by customers include:
-HRLD series 100, 150, 400:
Hydraulic fluid
***
Injection water
Common solvents
Kerosene
Diesel fuel
Aviation fuel (JP4, JP5)
Pure water
Alcohol
-The HRLD series 150JA/600JS is commonly used for:
Aldehyde
***
Ester
Aromatic hydrocarbons
Sodium hydroxide
Hydrogen peroxide
Ammonium hydroxide
*Viton ™ Sealing standards. For * * *, Kalrez can be used ™ seal up
HIAC HRLD series liquid particle counting sensorparameter
HRLD series models | Measurement range (μ m) | Concentration limit (<10%) | Flow rate (mL/min) |
HRLD-100 | 4 μm(c)-100 μm(c)* | 10,000 | 20-100 |
HRLD-100HC | 4 μm(c)-100 μm(c)* | 18,000 | 10-50 |
HRLD-150 | 1.3 min.-150 | 18,000 | 10-25 |
HRLD-150JA | 1.3 min.-150 | 18,000 | 10-25 |
HRLD-400 | 2.0 min.-400 | 10,000 | 20-100 |
HRLD-400HC | 2.0 min.-400 | 18,000 | 10-50 |
HRLD-600JS | 2.0 min.-600 | 6,000 | 30-200 |
*According to ISO 11171 and ISO 4406, 4 μ m (c)<2 μ m | |||
Pressure limit | 69 bar (1000 psi) | ||
Sample temperature limit | 65°C (150°F) | ||
Calibration Options | ASTM F658-87 (PSL sphere); ISO4402 (ACFTD calibration in oil); Or ISO11171 (MTD calibration in oil) For applications in the pharmaceutical process, the resolution of sensors can be tested in factories, and the basis for testing can be USP<788>. | ||
When placing an order, please specify | HRLD-100 or HRLD-100HC HRLD-150 or HRLD-150JA HRLD-400 or HRLD-400HC HRLD-600JS | ||
Compliance certification | According to EMC and low-voltage guidelines, it complies with CE certification for Class I laser products, meets IEC/EN60825-1 and 21 CFR1040.10, and has a laser noise of 50 |
If you want to learn more about this product or need professional personnel to answer your professional questions about product performance, after-sales service, etc., please join us immediately