Shanghai Huile Electric Co., Ltd
Home>Products>HL-871A Busbar Insulation Monitoring Device
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1881753568318321031365
  • Address
    No. 95 Shihuxin Road, Shihudang Town, Songjiang District, Shanghai
Contact Now
HL-871A Busbar Insulation Monitoring Device
HL-871A Busbar Insulation Monitoring Device
Product details

general outline Describe
With the development of electrical automation technology and computer technology in the power system, higher requirements have been put forward for intelligent devices in the power system. As an important intelligent device in the power system, the relay protection device will no longer have a single protection function, but should be a protection device that integrates measurement, metering, control, and communication. The HL-800A series microcomputer protection and measurement device is a high-performance protection and measurement device developed to meet the needs of the power system development and market. It integrates measurement, metering, control, and communication. This series of microcomputer protection and measurement devices adopts advanced 32-bit embedded microprocessors, fully isolated, high-speed and safe fieldbus technology, and user-friendly human-machine interfaces. Its performance and technical indicators are at the forefront of China. Mainly applicable to power systems and other industry users with voltage levels of 110KV and below.


particular drop
The HL-800A series microcomputer protection and measurement device has the following characteristics:
1. Adopting advanced 32-bit embedded ARM processors
2. Humanized human-machine interface, easy and intuitive operation
3. SOE and self-test report with power-off hold
4. Complete software and hardware self checking, redundant design of secondary watchdog software and hardware, strong anti-interference performance
5. Fully sealed embedded 5U standard chassis design, large screen with full Chinese character display, can be assembled or directly installed on the switchgear
6. Safe and reliable high-speed fieldbus technology, supporting dual networks, multiple communication interfaces, and multiple communication protocols
7. DCS measurement interface (4-20mA analog output)
8. The device is equipped with a clock synchronization interface to ensure that the device's clock is synchronized with the system


Specification


rated data
DC power supply: 220V ± 20% or 110V ± 20%
AC power supply: 85V~265V
AC voltage: 100/ V,100V
AC current: 5A or 1A
Frequency: 50Hz


Power consumption
DC circuit: ≤ 5W
AC voltage circuit: < 0.5VA/phase (at rated 220V)
AC current circuit: < 0.5VA/phase (rated at 5A)
< 0.1VA/phase (rated at 1A)


work environment

Environmental temperature: -10 ℃ to+55 ℃ to ensure normal operation

Relative humidity: 5~95%

Atmospheric pressure: 86~106KPa3.4

thermal stability
2 times the rated current for continuous operation
10 times the rated current can run continuously for 10 seconds
40 times the rated current can run continuously for 1 second

DCS measurement interface output
Output range: 4~20mA
Output accuracy: Level 0.5

Contact capacity
Jumping and closing outlet (normally open contact): 5A, DC 220V (suction)
Signal outlet (normally open contact): 5A, DC 220V (pull in)
Switching input: air contact input, conducting current<10mA

measurement accuracy
Voltage and current: Level 0.5
Frequency: 0.02Hz
P Q、COSΦ: Level 1
Remote signaling resolution:< 2ms
Electricity integration accuracy: Level 2
GPS timing accuracy:<1ms

communication
RS485: The communication speed is adjustable from 9.6 to 115.2 kbps, supports dual network, and the communication medium supports shielded twisted pair cables.
CAN: The communication speed can reach up to 1Mbps, supporting dual networks, and the communication medium supports shielded twisted pair cables.


anti-jamming performance
Capable of withstanding the severe level IV electrostatic discharge test specified in GB/T14598.14-1998 (idt IEC255-22-2) standard.
Capable of withstanding the harsh level III electromagnetic field interference test specified in GB/T14598.9-1995 (idt IEC255-22-3) standard.
Capable of withstanding 1MHz pulse group interference test of severity level III specified in GB/T14598.13-1998 (idt IEC255-22-1) standard.
Can withstand the rapid transient interference test of severity level IV specified in GB/T14598.10-1996 (idt IEC255-22-4) standard.

Mechanical properties
Vibration
The device should be able to withstand the vibration durability test with a severity level of 1 as specified in GB/T11287.
The device should be able to withstand the vibration response capability test with a severity level of 1 as specified in GB/T11287.
Impact
The device should be able to withstand the impact durability test with a severity level of 1 as specified in GB/T14537.
The device should be able to withstand the impact response capability test with a severity level of 1 as specified in GB/T14537.
Collision
The device should be able to withstand a collision test with a severity level of 1 as specified in GB/T14537.

Moisture and heat resistance performance
Capable of withstanding the damp heat test specified in Chapter 21 of GB7261

Mainly following standards
GB/T14598.13-1998 (idt IEC255-22-1) Electrical interference test for measuring relays and protection devices Part 1: 1MHz pulse group interference test
GB/T14598.14-1998 (idt IEC255-22-2) Electrical interference test for measuring relays and protective devices
Article 2: Electrostatic Discharge Test
GB/T14598.9-1995 (idt IEC255-22-3) Electrical interference test for measuring relays and protective devices
Article 3: Radiated Electromagnetic Field Interference Test
GB/T14598.10-1996 (idt IEC255-22-4) Electrical interference test for measuring relays and protective devices
Article 4: Fast Transient Interference Test
Other indicators meet the requirements of DL478-92 "General Technical Conditions for Static Relay Protection and Safety Automatic Equipment"

Basic configuration
The HL-871A busbar insulation monitoring device (hereinafter referred to as the device) is suitable for directional line protection and measurement in non directly grounded systems or systems grounded through arc suppression coils (including low resistance grounding) with voltage levels below 110KV.


Protection function
1. Bus voltage loss
2. Bus breakage
3. Bus grounding
4. Control circuit disconnection

Measurement and control function
1. 14 channel remote signal input acquisition, device remote signal displacement, accident remote signal
2. Normal circuit breaker remote control opening and closing
3. Telemetry: UA、UB、UC、IA、IB、IC、P、Q、COSΦ、F、3U0、3I0、UAB、UBC、UCA、UX
4. 2-channel pulse input


communication function
The communication card of the device supports multiple communication interfaces, and users can choose high-speed RS485 according to their engineering needs CAN。 The communication content mainly includes: measurement values (analog, switch values); Device status, fault information with time stamps, etc; Returning from afar.


Other functions
The device can automatically record various operational information of the device:
1. 12 protected SOE records
2. 24 remote signal displacement SOE records
3. Record of self diagnostic information for 12 devices
4. 6 remote control records
5. 24 running event records