Nominal diameter (mm) (Special specifications can be customized) |
Pipeline type: DN10 to DN3000 |
|
Insertion type: DN200~DN3000 |
||
Flow direction: |
Positive, negative, net traffic |
|
Range ratio: |
150:1 |
|
Repetitive error: |
± 0.1% of the measured value |
|
Accuracy level: |
Pipeline type: 0.5 level, 1.0 level |
|
Temperature of the tested medium: |
Ordinary rubber lining: -20 to+60 ℃ |
|
High temperature rubber lining: -20 to+90 ℃ |
||
PTFE lining: -30 to+100 ℃ |
||
High temperature PTFE lining: -20 to+180 ℃ |
||
Rated working pressure: (High voltage can be customized) |
DN6-DN80:≤1.6MPa |
|
DN100-DN250:≤1.0MPa |
||
DN300-DN1200:≤0.6MPa |
||
Flow rate range: |
0.1-15m/s |
|
Conductivity range: |
The conductivity of the measured fluid is ≥ 5 μ s/cm |
|
Current output: |
load resistance |
0~10mA:0~1.5kΩ |
4~20mA:0~750 kΩ |
||
Digital frequency output: |
The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the maximum current at the collector is 250mA |
|
Power supply: |
AC220V, DC24V or 3.6V batteries |
|
Require the length of the straight pipe section |
Upstream ≥ 5DN, downstream ≥ 2DN |
|
Connection method: |
The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988 |
|
Explosion proof grade: |
mdIIBT4 |
|
Protection level: |
IP65, Specially customized up to IP68 |
|
Environmental temperature: |
-25~+60℃ |
|
Relative temperature: |
5%~95% |
|
Total power consumption: |
Less than 20W |
model | Explanation | |||||||||||||
HQLDE— | internet traffic | □ | -□ | □ | □ | □ | □ | □ | -□ | □ | □ | □ | □ | |
HQLDR— | heat | □ | -□ | □ | □ | □ | □ | □ | -□ | □ | □ | □ | □ | |
Path diameter | 10-2200mm | |||||||||||||
Combination | S | Integrated type | ||||||||||||
L | Split type | |||||||||||||
Electrode material | M | Stainless steel | ||||||||||||
T | Ti (titanium) | |||||||||||||
D | Ta (tantalum) | |||||||||||||
H | Hastelloy alloy | |||||||||||||
P | Pt platinum | |||||||||||||
N | Ni nickel | |||||||||||||
A | Tungsten carbide (wear-resistant) | |||||||||||||
Output method | 0 | No output | ||||||||||||
1 | 4-20mA/1-5KHz | |||||||||||||
2 | 4-20mA | |||||||||||||
Lining material | X | Rubber | ||||||||||||
F | Polytetrafluoroethylene | |||||||||||||
P | F46 (high temperature) | |||||||||||||
J | PFA (wear-resistant) | |||||||||||||
T | ceramics | |||||||||||||
On site display | 0 | No on-site display | ||||||||||||
1 | On site display | |||||||||||||
Communication method | 0 | No communication | ||||||||||||
1 | RS485 | |||||||||||||
2 | RS232 | |||||||||||||
3 | Mobdus | |||||||||||||
4 | Hart | |||||||||||||
Grounding | 0 | No grounding ring | ||||||||||||
1 | There is a grounding ring | |||||||||||||
2 | There is a grounding electrode | |||||||||||||
Maximum traffic limit | (n) | Upper limit flow rate (range) m3/h | ||||||||||||
Work pressure | A | 0.6MPa | ||||||||||||
B | 1.0 MPa | |||||||||||||
C | 1.6 MPa | |||||||||||||
D | 2,5 MPa | |||||||||||||
measurement accuracy | 1 | 0.2 | ||||||||||||
2 | 0.5 | |||||||||||||
3 | 1 | |||||||||||||
medium temperature | L | 0-80 degrees | ||||||||||||
H | 0-150 degrees | |||||||||||||
power supplier | DC | 24V DC power supply | ||||||||||||
AC | 220V AC power supply |
5、 Selection of lining for sanitary clamp electromagnetic flowmeter:
Lining material |
Performance |
scope of application |
chloroprene rubber Neoprene |
Good wear resistance, excellent elasticity, high tensile strength, and resistance to corrosion from low concentration acid-base salt media, but not resistant to corrosion from oxidizing media. |
<80 ° C, general water, sewage, mud, slurry |
polyurethane Polyurethane |
Has excellent wear resistance, but slightly inferior acid and alkali resistance. |
<60 ° C, neutral and strongly worn mineral slurry, coal slurry, and mud. |
PTFE PTFE |
A material with the most stable chemical properties, capable of withstanding boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali, and various organic solvents, but not resistant to chlorine trifluoride and high-temperature oxygen difluoride. |
<180 ° C, strong corrosive media such as concentrated acid and alkali, sanitary media. |
F46 |
Chemical stability, electrical insulation, lubricity, non adhesiveness, and non flammability are similar to PTFE, but F46 material has better strength, aging resistance, temperature resistance, and low-temperature flexibility than PTFE. Good adhesion to metal, better wear resistance than PTFE, with good performance |
<180 ° C, hydrochloric acid, sulfuric acid, aqua regia, and strong oxidants, sanitary media |
6、 Selection of electrode materials for sanitary clamp electromagnetic flowmeter:
material |
Corrosion Resistance |
316L |
For nitric acid, sulfuric acid at room temperature<5%, boiling phosphoric acid, alkaline solution; Under certain pressure, media such as sulfurous acid, seawater, and acetic acid have strong corrosion resistance. |
Hastelloy HB |
Resistant to all concentrations of non oxidizing acids, bases, and non chlorinated hydrochloric acids such as hydrochloric acid, sulfuric acid, hydrofluoric acid, and organic acids at boiling point. |
Hastelloy HC |
Resistant to oxidizing acids such as nitric acid, mixed acids, or mixtures of chromic acid and sulfuric acid, as well as oxidizing salts and seawater |
titanium |
It can withstand corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming nitric acid), organic acids, alkalis, etc. It is not resistant to corrosion from relatively pure reducing acids (sulfuric acid, hydrochloric acid), but corrosion is greatly reduced when the acid contains oxidants (such as nitric acid and media containing Fe and Cu ions). |
tantalum |
It has excellent corrosion resistance similar to glass, except for hydrofluoric acid and concentrated sulfuric acid, and can withstand corrosion from almost all chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 175 ° C). It is not resistant to corrosion in alkali. |
7、 Selection of caliber and flow rate for sanitary clamp electromagnetic flowmeter
Nominal diameter (mm) | Measurable flow range (m3/h) | Effective measurement flow range (m3/h) | Nominal diameter (mm) | Measurable flow range (m3/h) | Effective measurement flow range (m3/h) |
4 | 0.0135~0.4522 | 0.0135~0.4522 | 250 | 8.8313~2119 | 52.9875~1766 |
6 | 0.0305~1.0173 | 0.0305~1.0173 | 300 | 12.717~3052 | 76.302~2543 |
8 | 0.0543~1.8086 | 0.0543~1.8086 | 350 | 17.31~4154 | 103.86~3461 |
10 | 0.0142~3.3912 | 0.0848~2.826 | 400 | 22.61~5425 | 135.65~4521 |
15 | 0.0318~7.6302 | 0.1908~6.3585 | 450 | 28.62~6867 | 171.68~5722 |
20 | 0.0566~13.5648 | 0.3392~11.304 | 500 | 35.33~8478 | 211.95~7065 |
25 | 0.0883~21.195 | 0.5298~17.6625 | 600 | 50.87~12208 | 305.2~10173 |
32 | 0.1447~34.7258 | 0.8682~29.9382 | 700 | 69.24~16616 | 415.4~13847 |
40 | 0.2261~54.2592 | 1.3565~45.216 | 800 | 90.44~21703 | 542.6~18086 |
50 | 0.3533~84.78 | 2.1195~70.65 | 900 | 114.46~27468 | 686.7~22890 |
65 | 0.5970~143.28 | 3.5819~119.39 | 1000 | 141.3~33912 | 847.8~28260 |
80 | 0.9044~217.03 | 5.4259~180.86 | 1200 | 203.5~48833 | 1221~40694 |
100 | 1.413 ~339.12 | 8.478~282.6 | 1400 | 277~66467 | 1662~55389 |
125 | 2.2079~529.87 | 13.2468~441.56 | 1600 | 361.8~86814 | 2171~72345 |
150 | 3.1793~763 | 19.0755~635.85 | 1800 | 457.9~109874 | 2747~91562 |
200 | 5.652~1356 | 33.912~1130.4 |