Hana chlorine dioxide analyzer HI96738
Hanna Chlorine Dioxide Analyzer HI96738: Featuring an innovative optical system design, it boasts excellent accuracy, repeatability, and measurement t
Product details

Introduction to Hana Chlorine Dioxide Tester HI96738:

Measurement range: 0.00 to 2.00 mg/L (ppm) CIO2
Kind reminder: To ensure the accuracy and stability of measurement readings, it is strongly recommended that you conduct measurement and analysis immediately after collecting the water sample to be tested; The carbon dioxide water sample to be tested must be stored in a sealed dark glass small caliber bottle, ensuring that it is filled as much as possible. The storage temperature should be controlled within 25 º C (77 º F), avoiding stirring or exposure to light.
Adopting innovative optical system design, with excellent precision, repeatability, and measurement time required, Hanna's carefully designed CAL Check ™ The function allows for performance validation and calibration of instruments using NIST traceable standards, with built-in reaction timers to ensure results between sample measurements and users, Good Laboratory Practice (GLP) display of the last user calibration date and time, battery status indicator lights, and automatic shutdown settings.

Hana chlorine dioxide analyzer HI96738 parameters:

Chlorine is a commonly used water disinfectant with a wide range of applications, from the treatment of drinking water and wastewater to the sanitation treatment of swimming pools and mineral spring resorts, as well as disinfection and sterilization in food processing; Based on microprocessor control, it has self checking function and can quickly measure residual chlorine concentration accurately.

The combination optical system of narrowband interference filter and silicon photodetector in the chlorine dioxide [CIO2] photometric colorimeter ensures accurate measurement readings every time;
Hanna's meticulously designed CAL Check ™ Function HI96738-11 chlorine dioxide [CIO2] NIST traceable calibration group to verify the performance status of HI96738 chlorine dioxide [CIO2] photometric colorimeter.
The dedicated colorimetric cup locking design ensures that the colorimetric cup is inserted into the same position in the measuring unit each time to maintain the path length of * for accurate results,

It is simple and convenient to add reagents to the water sample to be tested. The reagents will react with chlorine dioxide [CIO2] in the water sample to be tested. Based on the color change after the reaction between the reagents and the water sample, the concentration value of chlorine dioxide [CIO2] can be determined using a chlorine dioxide [CIO2] photometric colorimeter.

Built in timer - ensures that the tested water sample and chlorine dioxide [CIO2] reagent react according to the internally set standard time. At the end of the timer, the instrument will automatically read the reading, ensuring the accuracy of reaction time for multiple batches of measurements.

GLP Function - Record the date of the last user calibration execution

Error messages - warning issues on the display screen, including unlimited, out of range, and under range readings, as well as light source errors;

Automatic shutdown - measurement mode for 10 minutes, or in calibration mode, it will automatically shut down after one hour of inactivity;

Battery status - battery level indicator, 【 ▊▊▊ 】 indicates 100% battery level; 【▊▊】 indicates that the battery level is ≤ 60%; 【 ▊ 】 indicates that the battery level is ≤ 30%; When ≤ 10%, the battery icon flashes, prompting the user to replace the battery in a timely manner.

HI93738-01 Customized Chlorine Dioxide [CIO2] Reagent with 100 Predictions

HI93738-03 customized chlorine dioxide [CIO2] reagent with 300 predicted times


Chlorine dioxide [CIO2] reagent is suitable for the range of 0.00 to 2.00 mg/L (ppm) CIO2. It is a pre made high-quality chlorine dioxide [CIO2] measurement reagent that has been rigorously certified with various measuring tools and containers, carefully prepared in a constant temperature and humidity environment that meets the requirements, and can be traced back to NIST standard reference materials (SRM). It is convenient and fast to achieve rapid and accurate colorimetric measurement of chlorine dioxide [CIO2], following the recommended method by USEPA, and reacting copper and quinoline reagents;

Chlorine dioxide [CIO2] reagent has been rigorously certified with various measuring tools and containers, carefully prepared in a temperature and humidity environment that meets the requirements, and can be traced back to NIST standard reference materials (SRM)
Easy and fast operation

Take 1mL of HI93737A-0, HI93737B-0, and then 2mL of HI93737C-0, HI93737D-0 respectively. Finally, add 3 drops of pre made silver [Ag] reagent such as HI93703-51 to the water sample to be tested [see operation manual for details]. After the reaction between the sample containing silver [Ag] and the reagent, the color of the sample will change. Then measure the amount of silver [Ag] using colorimetric method, and use the recommended HI96737 and HI833XX series photometers to measure the color change. The concentration of silver [Ag] is displayed as ppm (mg/L) reading.

Kind reminder: To ensure the accuracy and stability of measurement readings, it is strongly recommended that the optimal temperature range for the sample to be tested be 20 to 24 º C

HI96738-11 Chlorine Dioxide [CIO2] NIST Measurement Curve Calibration Group

Standard value @ 25 º C: 0.00 and 1.00 ± 0.10 mg/L (ppm) CIO2

It is a set of high-quality products produced in Hanna's strict and advanced production environment and equipment, accompanied by factory analysis certificates, batch numbers and expiration dates for easy traceability, and users can regularly calibrate and correct the built-in standard curve of HI96738 chlorine dioxide [CIO2] photometer, which can prevent internal curve deviation caused by other factors of the light source lamp and ensure accurate and reliable measurement data.

Special Reminder:

In order to ensure measurement accuracy and reading reliability, it is recommended that users use the HI96738-11 chlorine dioxide [CIO2] calibration group to verify the internal standard curve of the HI96738 chlorine dioxide [CIO2] measuring instrument before each use. If the calibration value is within the specified range, users can measure normally. If it exceeds or falls below the specified calibration value range, while ensuring that the operation is correct, check the following factors:

--It is necessary to check whether the calibration group is within its validity period or whether contamination or damage has occurred due to storage reasons;

--Whether the glass colorimetric dish is contaminated or scratched, and whether the battery level is above 30%;

Excluding the above factors, it indicates that the instrument light source system has decayed and needs to be returned to the Hana repair center for processing.

The colors in the product images are for reference only, and the actual colors shall prevail

HI731331-400.jpg

HI731318-400-270.jpg

HI731333 Glass Colorimeter Set

Composed of HI731331 high-quality glass colorimetric cup and HI731335 customized special colorimetric cup cover,

HI731318 customized special colorimetric dish ultra-fine fiber cloth cleaning cloth

Using ultra-fine fiber cloth to effectively clean the dirt, grease, and fingerprints on the colorimetric dish, ensuring that the glass colorimetric dish is clean and free of debris, and ensuring accurate and reliable measurement; When using colorimetric dishes in photometric and turbidity measuring instruments, it is crucial to ensure that the dishes are clean and free of scratches to obtain accurate measurements; Any interference in the optical path will affect the measurement accuracy, and using HI731318 ultra-fine fiber cloth can effectively reduce this situation.

HI93703-50 customized anti-static glass colorimetric dish cleaning solution

Ensure that glass colorimetric dishes and other laboratory glassware are kept clean and free of defects to obtain accurate readings. The specialized formula of colorimetric dish cleaning solution has anti-static function, ensuring that the glass colorimetric dish used for photometric colorimetry and turbidity measurement can be used at any time;

Special care must be taken when cleaning, preparing, and handling glass colorimetric dishes. After cleaning the glass colorimetric dish with HI93703-50 specialized anti-static glass colorimetric dish cleaning solution, the glass colorimetric dish should be rinsed multiple times with distilled water or deionized water and completely air dried. Each bottle can be traced back to the batch number and expiration date.

HI93703-58 custom glass colorimetric dish repair lubricant

Used for coating on the walls of specialized glass colorimetric dishes for photometric and turbidity purposes, to prevent small scratches on the glass colorimetric dishes from interfering with the measurement of lower sample readings;

The specialized repair solution for colorimetric dishes has the same refractive index as glass in colorimetric dishes.

HI731318 ultra-fine cleaning cloth

HI93703-50-400-260.jpg

HI731331 glass colorimetric dish HI93703-50 cleaning solution

HI731335-400.jpg

30ml-瓶-400.jpg

HI731335 glass colorimetric dish cover HI93703-58 repair lubricant

HI72083300-400.jpg

Presenting precise measurements
Hana Instrument provides a complete set of chlorine dioxide [CIO2] measuring instruments, making it easy and convenient for users to order the instruments. Users can use them immediately without the need to order other accessories.

Complete package

All instruments and accessories of the chlorine dioxide [CIO2] analyzer are neatly packaged in a sturdy carrying case, meeting the needs of users for easy and fast on-site measurement.

Special reminder: The product configuration shown in the product pictures of the carrying case is for reference only. Users should refer to the actual product configuration received

HI83300-100_v2-400.jpg

HI83300-100 Pre processor for Water Sample to be Tested

In order to ensure measurement accuracy, reading stability, and repeatability, it is necessary to ensure the suspended solids or color of the water sample to be tested, as suspended solids or color are crucial for photometric colorimetric determination. Therefore, before measurement, it is necessary to determine whether there are interference factors such as suspended solids or color in the water sample to be tested.
The water sample pre-processing unit consists of: