Hash/HACH, 2100AN Laboratory Turbidity Meter from the United States
In addition to having all the functions of 2100N, the 2100AN laboratory turbidity meter has expanded its turbidity measurement range and added chromat
Product details
In addition to having all the functions of 2100N, the 2100AN laboratory turbidity meter has expanded its turbidity measurement range and added chromaticity measurement function. Suitable for turbidity measurement in different fields such as drinking water, wastewater, surface water, groundwater detection, education, scientific research, industrial process control, and product quality control. The programmable signal averaging function, automatic calibration function, and built-in printer printing function of the instrument greatly optimize the testing process and facilitate data management; The ratio measurement mode developed using Hash Company's patented technology effectively ensures the elimination of chromatic interference; The sensitive fault self diagnosis function can promptly remind users to discover and eliminate instrument faults; The sample testing chamber can be purged with air to prevent light scattering caused by water vapor condensation, making it suitable for measuring turbidity of cold and hot water samples.The instrument has data storage function, which can be accessed throughHachLink TM The software willThe experimental data is directly downloaded to the computer for easy storage and management of the data. The built-in printer can directly printMeasurement results and related parameters.
Technical indicators:
Compliant with standard: Meets the requirements of USEPA method 180.1
Range: Turbidity: 0-10000 NTU
Chromaticity: 0-500CU
Accuracy: Turbidity: (1) 0-1000NTU: 0.01NTU or ± 2% of the reading; (2)1000-4000NTU: ± 5% of the reading; (3)4000-10000NTU: ± 10% of the reading.
Chromaticity: (1) 0-30CU: ± 2CU; (2)0-500CU:±5CU
Resolution: Turbidity: 0.001NTU
Chromaticity: 1CU
Ratio measurement function: available
Minimum sampling volume: 20mL
Measurement mode: NTU,NEP,EBC,ABS,T%, Chromatic units, user-defined units
Reproducibility: ± 1% of reading or 0.01NTU
Power supply: 230V, 50/60Hz
Operating environment: 10-40 ℃, 90% relative humidity, no condensation at 25 ℃
Instrument weight: 3.43 kilograms
Ordering Guide:
2100ANThe standard configuration of the laboratory turbidity meter includes: one unit2100ANThe mainframe of the laboratory turbidity meter,6A sample pool, packaged in a sealed small bottleStablCalFirst grade standard solution, silicone oil, user manual, etc.
47001-02 2100ANLaboratory turbidity meter and related accessories
2100ANThe standard configuration of the laboratory turbidity meter includes: one unit2100ANThe mainframe of the laboratory turbidity meter,6A sample pool, packaged in a sealed small bottleStablCalFirst grade standard solution, silicone oil, user manual, etc.
47001-02 2100ANLaboratory turbidity meter and related accessories