VIP member
Hitachi Chromaster High Performance Liquid Chromatography System
Hitachi Chromaster High Performance Liquid Chromatography System
Product details
Product Introduction
HPLC is based on today and oriented towards the future
Cutting edge technology Consistently adhere to“Applying the most advanced technology to the forefront”Hitachi, with a strong belief in the widespread application of analytical instruments and a focus on the long-term development of liquid chromatography, continues to“ Lachrom Elite”Afterwards, a new high-end liquid chromatography instrument was launched with great weight—& mdash; Chromaster! “ Chromaster”It is a newly coined word, taken from an English wordChromatograph(Chromatography) andMaster(Master). This word expresses a beautiful vision of Hitachi, which is to develop and provide a top-level, high-performance liquid chromatography system. As a powerful tool, it will serve those who have received professional training“Master level”Chromatography workers make greater contributions! Technical parameters: Infusion system ·Better gradient performance and higher flow accuracy By utilizing the function of doubling the switching frequency of the solenoid valve,chromasterIntroduced a new type of low-pressure gradient system—& mdash;High frequency mode(High Frequent Mode).HFMUnique to Hitachi“High speed feedback real-time control”The system works together to greatly suppress liquid pulses, improving gradient accuracy and reproducibility of retention time. ·Low capacity online degassing unit Low capacity(480μ L/ch)The online degassing device has shortened the solvent replacement time and reduced solvent consumption. ·Automatic drainage function Through chromatographic workstationsGUIController or control panel, can set any flow rate (maximum)9.999mL/min),At any time (maximum)30min)Realize automatic drainage. Automatic sampling system ·Excellent injection accuracy By relying on the configured high-precision injector drive unit, excellent injection accuracy can be achieved. ·Extremely low sample residue Hitachi has greatly reduced the dead volume caused by residual in the flow path of the automatic sampler, and adopted a pump for cleaning the outer wall to achieve extremely low sample residue. ·Special online degassing device for automatic sampler Built in, does not take up additional space ·Automatic sampler with temperature control device Controllable temperature range: (room temperature)-21℃)To (room temperature)+25℃)A wider temperature control range, expanding the application field of the instrument, preventing the crystallization of compounds in the sample bottle to ensure the stability of the sample. Column constant temperature system ·Standard preheating function The standard preheating module is based on Peltier heating/The cooling control function greatly improves the symmetry and sharpness of the peak shape. ·A wider temperature control range The temperature control range of the column temperature box is (room temperature)-15℃)To (room temperature)+60℃)It can meet various application needs. ·Large column temperature box Easy to accommodate with protective pillars300mmAnalysis column, internal dimensions wide375mmUp and down high114mm, Open itLFont shaped door, convenient for connecting and placing chromatography columns, can accommodate3root300mmChromatographic column. ·Chromatographic Column Management System adoptchromasterThe chromatographic column management system can manage log information for chromatographic columns and protection, regardless of which chromatographic column manufacturer produces them. The log information of the chromatographic column is saved inIDIn the tag, log information can be obtained through the connector installed on the column temperature box or the computer'sUSBInterface for reading and writing,IDLabels can be reused repeatedly. detecting system · CM-5410/5420Ultraviolet/UV Visible Detector Dual wavelength high-sensitivity detection, especially for the examination of drug-related substances. The dual wavelength detection function can be achieved under shorter data acquisition intervals, and each wavelength data acquisition interval can be set as800msEven400msIt can obtain better and sharper peak shapes. · CM-5430Diode array detector Higher qualitative analysis ability Wide wavelength range(190~900nm)And hyperspectral resolution (with1024bitDiodes)chromasterThe diode array detector is committed to creating the world's highest level of high-resolution analysis. Lower noise The noise level of the diode array detector is comparable to that of the ultraviolet detector, supporting high-sensitivity analysis. Lower drift Adopting a fan with adjustable air volume and a specific cover plate on the splitter greatly reduces the impact of temperature changes around the optical system, further reducing drift. ·Constant temperature circulation pool The constant temperature flow cell minimizes the impact of room temperature changes, making the detector baseline more stable and the data more reliable. Main features: 1. Excellent performance · CM-5110pump More gradient performance and higher flow accuracy · CM-5210Automatic sampler Excellent injection accuracy and extremely low sample residue · CM-5310Column temperature box Standard preheating function and wider temperature control range · CM-5430Diode array detector Higher qualitative analysis ability, lower noise, lower drift · CM-5410/5420Ultraviolet/UV Visible Detector Dual wavelength high-sensitivity detection, especially for the inspection of drug-related substances ·Constant temperature circulation pool The constant temperature circulation pool minimizes the impact of room temperature changes to the greatest extent possible 2.Easy to operate · GUIcontroller Optimized user interface, independent module operation ·Automatic drainage function Simplify the movement of the pump ·Automatic plunger cleaning function Prevent the precipitation of salt on the surface of the plunger ·Low capacity online degassing unit Low capacity(480μ L/ch)The online degassing device has shortened the solvent replacement time and reduced solvent consumption ·Automatic sampler with temperature control device Controllable temperature range: (room temperature)-21℃)To (room temperature)+25℃) ·Special online degassing device for automatic sampler Built in, does not take up additional space ·Combination of a specially designed cover plate for a spectrophotometer and a fan with adjustable air volume Shorten the preheating stabilization time (diode array detector) ·Large column temperature box Easy to accommodate with protective pillars300mmAnalysis column ·Chromatographic Column Management System The log information of the chromatographic column is saved inIDIn the tag, log information can be obtained through the connector installed on the column temperature box or the computer'sUSBInterface for reading and writing,IDLabels can be reused repeatedly. ·Solvent tank with power supply module The organizer can be placed in multiple solvent bottles ·System size Reduce height to save space 3. Durable and long-lasting ·All outer covers are made of materials that are heat-resistant, corrosion-resistant, and UV resistant. The inner walls of the modules are made of stainless steel to avoid corrosion caused by humid air and solvent evaporation. In order to minimize the negative impact of solution leakage on the module, we have adopted the optimal flow path design in the system. 4. Other functions ·The automatic sampler has a door lock device ·When performing a lamp replacement operation, the power automatically shuts off ·All modules are equipped with leakage sensors ·To prevent non-volatile solvent leakage, the column temperature box is equipped with both gas sensors and liquid sensors |
Online inquiry