Hitachi Thermal Mechanical Analyzer TMA7100&TMA7300
Hitachi Thermal Mechanical Analyzer TMA7100TMA7300 Hitachi's TMA (Thermal Mechanical Analyzer) is used to evaluate the expansion or contraction of sam
Product details

Hitachi Thermal Mechanical Analyzer TMA7100&TMA7300

Hitachi's TMA (Thermal Mechanical Analyzer) is used to evaluate the expansion or contraction of samples over a wide temperature range. These parameters are crucial for design engineers, and our TMA analyzer is also used for quality assurance or factory inspection to ensure that customer products meet specifications. Hitachi's multifunctional TMA can also perform other analysis tasks in one instrument, such as creep measurement, stress relaxation measurement, thermal shrinkage stress measurement, stress-strain curve, and dynamic thermomechanical analyzer measurement.


Has high sensitivity and wide range characteristics

Sensitivity detection, measurement range, linear load cooling optional type

The TMA sensitivity reaches 0.01um, which is twice that of the company's previous products. The measurement range reaches displacement ± 0.5 and load ± 5.8N. Support various applications from static measurement to dynamic measurement.


Support multiple sample shapes

This product is a fully expanded TMA, so it can measure samples with larger diameters of 10mm x 25mm in height.


Rich cooling options

Cooling devices can be selected according to the measurement purpose:

Fully automatic liquid nitrogen cooling device (liquid nitrogen gasification control)

Electronic cooling device

Liquid nitrogen Dewar flask (manually cooled)

Fan automatic air cooling device


characteristic

TMA7100

TMA7300

Sample tube

Quartz, metal

alumina

probe

Expansion and compression quartz probe needle in quartz probe 2, conical needle in quartz probe 2, tensile quartz probe 2, metal tensile probe 2, quartz bending measurement accessories 2, sapphire body expansion accessories 2

Alumina expansion and compression probe

temperature range

-170℃~600℃

Room temperature~1500 ℃ ⋇ 1

Probe fixation method

cantilever type

TMA range

±5mm

TMA RMS noise/sensitivity

0.005um/0.01um

Load range (resolution)

±5.8N(9.8uN)

heating rate

0.01~100℃

Larger sample size

Diameter 10mm x height 25mm x width 5mm x thickness 1mm x length 25mm

Diameter 10mm x height 25mm

Sample length measurement

Automatic length measurement

atmosphere

Atmosphere, inert gas, depressurization (~13pa) ⋇ 2, swelling ⋇ 2, humidity control ⋇ 2

load control

Fixed (± 5.8N) constant speed (9.8x10-2~9.8x106mN/min) frequency (0.001~1Hz) combination (up to 40 steps)

displacement-controlled

Fixed (± 5000um) constant speed (0.01~106um/min) frequency (0.001~1Hz) combination (up to 40 steps)

Gas flow control

Mass flow control unit Gas control unit Flow meter

cooling system

Fully automatic liquid nitrogen cooling device:- 150℃~600℃

Electronic cooling device:- 60℃~450℃

Fan automatic air cooling: room temperature~600 ℃

Liquid nitrogen cooled Dewar cup kit:- 170℃~600℃

Fan automatic air cooling

Room temperature~1500 ℃