Horizontal liquefied petroleum gas storage tank
Horizontal liquefied petroleum gas storage tank
Product details


Technical Parameter
  1. undefined

    characterization

    This horizontal storage tank product is used to store media mainly composed of liquefied petroleum gas (propane). Its saturated vapor pressure at 50 ℃ is less than or equal to 1.63MPa, and the H2S solubility is less than 7.7mg/L. The storage tank is in the shape of a cylindrical body
    Composed of a cylinder, a head, and a saddle, the main material is Q345R. Conventional pipe openings include manholes, safety valve ports, drain ports, emergency injection ports, balance ports, gas phase ports, vent ports, balance ports, gas phase ports, outlet ports, inlet ports, and liquid ports
    Gauge interface, pressure gauge interface, thermometer interface; The color code paint of the tank body is silver powder or medium gray, and the medium is flammable and explosive. The medium loading capacity is 0.9, leaving 10% gas phase space. The working pressure is 1.63MPa and the design pressure is 1.77M
    The maximum allowable working pressure is 1.82MPa, and the design temperature is -20/54 ℃. The design, manufacturing, testing, and acceptance of this product comply with the following standards and regulations: (1) TSG 21-2016 "Safety Technical Supervision Regulations for Fixed Pressure Vessels
    《 Cheng 》 (2) GB150.1-150.4-2011 《 Pressure Vessels 》
    Instructions for use

    The user of this product should go to the registration authority to complete the registration procedures before or within 30 days after the product is put into use,
    And in accordance with the Order of the President of the People's Republic of China (No. 4) "Special Equipment Safety Law of the People's Republic of China" and the Order of the State Council (No. 549) "Special Equipment Safety Law
    Regulations on Safety Supervision of Equipment ", General Administration of Quality Supervision, Inspection and Quarantine" Safety Technical Supervision Regulations for Fixed Pressure Vessels "and other relevant regulations
    Requirement: Seriously implement safety technology management work, strictly prohibit the use in violation of regulations, prevent overloading, overheating, and overpressure use, and ensure the safety and safety of products
    Reasonable use.

    1) The technical director of the using unit must be responsible for the safety technology management of pressure vessels, and personnel with relevant professional knowledge of pressure vessels should be designated to be responsible
    Safety technology management of equipment.

    2) The user unit should formulate equipment process operation procedures, job operation procedures, and job responsibilities, and clarify the requirements for safe operation of pressure vessels.
    3) Equipment safety management personnel and operators shall hold corresponding special equipment operator certificates. The user unit should regularly conduct safety checks on the operators
    Comprehensive education and professional training assessments are conducted to ensure that operators have the necessary knowledge and skills for safe operation of pressure vessels, and to update their knowledge in a timely manner,
    Ensure that the operators master the operating procedures and emergency measures for accidents, and work according to the regulations.

    4) When the equipment is newly put into use or restarted after maintenance, an air tightness test should be conducted at the design pressure to check the sealing of the equipment and pipeline system, and to conduct
    Nitrogen gas can only be filled with liquefied petroleum gas when the oxygen content is no more than 3% after sampling analysis.

    5) During equipment start-up and shutdown, pressure and temperature should be slowly increased and decreased to control pressure and temperature fluctuations; During the use of the equipment, the minimum pressure inside the tank is not
    It should be less than 0.05MPa to prevent air from entering the tank.

    6) The equipment body and safety accessories should be regularly inspected as required, and any safety hazards discovered during the inspection should be promptly eliminated; Each safety attachment should be ensured
    Ensure safe and reliable operation within its inspection validity period (keep the shut-off valve fully open and lead sealed for related maintenance and replacement).

    7) The user unit should develop strict accident emergency plans and conduct drills, which should cover equipment abnormal situations (pressure, temperature, liquid level reaching)
    Situations such as unexpected value, safety attachment failure, small leakage, large leakage, and explosion and fire.

    8) The filling coefficient of this product is in accordance with the drawing requirements, and excessive filling is strictly prohibited; Personnel are prohibited from carrying pressure or media for maintenance operations.