Integrated hot and cold temperature controller
product
Cold water machines, oil coolers, air-cooled freezers, explosion-proof chillers, ice water machines, frozen water machines, air-cooled chillers, industrial chillers, electroplating chillers, water-cooled chillers, air-cooled chillers, screw chillers, laser chillers, low-temperature chillers, integrated cold and hot temperature controllers, environmentally friendly chillers and other types are complete, reliable in quality, advanced in technology, strict in management, excellent in quality, and perfect in after-sales service!
High quality compressor
As the heart of the chiller, we choose the brand new original compressor from Europe, America, and Japan, which has built-in safety protection, is safe, quiet, energy-saving, and durable.
Efficient evaporator
1. Coil water tank type: Stainless steel thick water tank evaporator, made of imported high-purity copper pipes, with built-in automatic water replenishment device, eliminating the need for expansion water tank in engineering installation, convenient for installation and maintenance, and suitable for special occasions such as large temperature difference and small flow rate.
2. Shell and tube type: high-efficiency copper tube internal thread evaporator (note: if using a closed water tank, it is recommended to use a shell and tube evaporator)
Condenser
Made of high external thread copper pipes from Kobe, Japan, with large heat dissipation and compact size. Designed and manufactured using the latest CAD/CAM technology, in conjunction with CNC machining centers, the structure is compact, efficient, and energy-saving.
Integrated hot and cold temperature controller
Equipped with a precision electronic temperature controller, the water temperature is accurately controlled within 5-35 degrees Celsius. It has built-in compressor overload protection device, circulating water pump overload control device, system low pressure abnormal protection device, high-efficiency imported drying filter and inflation valve, maintenance manual valve interface and other devices to ensure reliable and safe operation of the machine and facilitate maintenance and repair
Integrated hot and cold temperature controller
The optional water pump device is equipped with imported high-efficiency energy-saving water pumps according to the user's engineering design requirements, making the installation and use of the chiller quick and convenient.
Integrated hot and cold temperature controller
The multifunctional operation panel is equipped with an ammeter, control system fuse, compressor and water pump switch buttons, electronic temperature controller, various safety protection fault lights, display of cold water outlet, cold water inlet and set temperature options, and unit start and operation indicator lights, making it easy to use.
The integrated cold and hot temperature controller comes in single machine, dual machine, and multi machine combinations, with high energy efficiency and a reasonable internal layout, effectively reducing energy consumption. All pipes are made of copper and are seamlessly welded. After industrial design, the appearance is beautiful and the human-machine relationship is optimized.
Integrated hot and cold temperature controller
Safe and balanced operation, minimal vibration, and simple installation;
The unit has a compact structure, small footprint, light weight, and is easy to transport;
The control interface directly displays the fault content, which facilitates timely understanding and troubleshooting of the fault
Before leaving the factory, various performance tests are completed, and customers only need to connect the inlet and outlet pipes and power supply to operate, reducing installation time and costs.
Integrated hot and cold temperature controller
The unit can flexibly design the external dimensions according to the conditions of the computer room. Welcome to sample production.
Multiple refrigerant options are available, and the unit can provide refrigerant media such as R22, R407C, R134a, etc.
We can produce units with different power supply standards according to the power supply of different countries and regions. We can also customize chiller units and various high-voltage non-standard units such as anti-corrosion and saltwater units according to user requirements.
Integrated hot and cold temperature controller
The unit is equipped with multiple safety protection measures to ensure its normal operation.
All units undergo 100% testing through a safety inspection system before leaving the factory to ensure that their performance meets the standards.
The product is widely applicable to:
The injection molding and vacuum forming industry, pharmaceutical industry, electroplating industry, machinery industry, chemical industry, die-casting industry, hardware industry, electronics industry, rubber industry, food industry, automobile manufacturing industry, textile industry, jewelry industry, breeding industry, papermaking industry, printing industry and other industries can accurately control the temperature required for modern industrial mechanization production, thereby improving production efficiency and product quality
Category Type |
Water chiller technical parameters table for integrated temperature control machine |
||||||||||||||
Model number |
GY-3WC |
GY-4WC |
GY-5WC |
GY-6WC |
GY-8WC |
GY-10WC |
GY-12WC |
GY-15WC |
GY-20WC |
GY-25WC |
GY-30WC |
GY-40WC |
GY-50WC |
||
Customized cooling capacity |
50Hz |
Btu/h |
33457 |
44041 |
54624 |
66471 |
88765 |
94637 |
123806 |
129096 |
221229 |
267316 |
344746 |
442454 |
534632 |
Cooling capacity |
KW |
9.8 |
12.9 |
15.7 |
19.5 |
25.8 |
31.5 |
37 |
47.8 |
65.3 |
78.3 |
98 |
130.7 |
158.7 |
|
|
Kal/h |
8426 |
11095 |
13760 |
16745 |
22360 |
27434 |
33453 |
41009 |
55718 |
67326 |
86843 |
112564 |
143652 |
|
|
USRT |
2.8 |
3.7 |
4.5 |
5.5 |
7.4 |
9.1 |
11.2 |
13.8 |
19.1 |
22.3 |
28.7 |
36.9 |
45.75 |
|
Power supply input |
|
380-415V/3Phase/50Hz |
|||||||||||||
Compressor power |
KW |
2.63 |
3.39 |
4.11 |
5.25 |
6.76 |
8.18 |
9.78 |
12.27 |
16.4 |
19.2 |
24.46 |
27.2 |
33.7 |
|
Flow regulator |
capillary/Thermal expansion valve |
||||||||||||||
Refrigerant |
R22/R134a/407c |
||||||||||||||
condenser |
Style Style |
High efficiency copper tube with internal thread (shell and tube type) |
|||||||||||||
Cooling water flow rate |
m3/h |
2.13 |
2.85 |
3.66 |
4.32 |
5.73 |
7.02 |
8.51 |
10.59 |
14.64 |
16.99 |
21.96 |
31.08 |
39.25 |
|
port size |
DN |
25 |
25 |
25 |
25 |
40 |
40 |
40 |
50 |
65 |
65 |
65 |
80 |
80 |
|
evaporator |
Style Style |
Efficient copper tube (water tank coil type)/Shell and tube type |
|||||||||||||
Evaporator |
Water tank capacity L |
55 |
58 |
60 |
60 |
118 |
175 |
175 |
280 |
360 |
360 |
410 |
505 |
540 |
|
Chilled water flow rate |
m3/h |
1.69 |
2.25 |
2.88 |
3.35 |
4.48 |
5.49 |
6.68 |
8.23 |
11.56 |
13.33 |
17.36 |
25.76 |
27.65 |
|
Frozen water connection port |
DN |
25 |
25 |
25 |
25 |
40 |
40 |
40 |
50 |
65 |
65 |
65 |
80 |
80 |
|
Built in water pump |
horsepower |
HP |
0.5 |
0.5 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
3 |
3 |
5 |
7.5 |
Safety protection |
tall/Low pressure switch protection, high exhaust protection, thermal fuse, compressor thermal protector, overcurrent relay, phase sequence/Phase loss protector, etc |
||||||||||||||
High / low pressure switch protection, protection, hot melt season, high exhaust heat protector for a overcurrent relay, phase sequence protector. |
|||||||||||||||
Mechanical dimensions (mm) |
Long (L) |
890 |
890 |
900 |
900 |
1200 |
1200 |
1200 |
1650 |
1650 |
1650 |
1800 |
2050 |
2050 |
|
Width (W) |
480 |
500 |
500 |
500 |
710 |
710 |
710 |
710 |
710 |
710 |
720 |
980 |
980 |
||
High (H) |
830 |
850 |
850 |
850 |
1200 |
1200 |
1200 |
1650 |
1650 |
1650 |
1750 |
1800 |
1800 |
||
Machine weight |
Kg |
120 |
130 |
135 |
185 |
320 |
340 |
355 |
650 |
750 |
1050 |
1360 |
1390 |
1430 |
The above parameters are subject to change without prior notice |
The cooling capacity is based onupperParameters are standard
●Inlet temperature of chilled water 20℃●Temperature at the outlet of chilled water 15℃●Cooling water inlet temperature 40℃●Cooling water outlet temperature 45℃
1: Scope of work: Cooling air outlet temperature 22 ℃ to 50 ℃, cooling air temperature difference value 3.5 ℃ to 6.5 ℃, chilled water outlet temperature 5 ℃ to 20 ℃, chilled water temperature difference 2.5 ℃ to 7 ℃
2: Ordering Notice: Please specify whether the evaporator is a water tank or shell and tube type, whether a built-in water pump is required, the flow rate and pressure of the water pump, which must be specified at the time of ordering
3: Welcome customers to propose different requirements for new selection and manufacturing. We reserve the right to make changes to product design and specifications without consent