Functional Features Details
The detailed introduction of the functions of HX-E water quality analyzer is as follows
Using a cold light source emitter
The instrument adopts a semiconductor cold light source emitter, a unique optical circuit design, and strong anti-interference ability,
The measurement data has high accuracy and good stability, and the lifespan of the light source can reach tens of thousands of hours.
Large screen Chinese operation
Dual LCD display, large screen LCD backlight display, 240 * 128 dot matrix,
Chinese operating interface, user-friendly programming.
Provide software support
Provide supporting software that can connect to a computer to view, store, and print relevant measurement data
And measure the curve.
Comes with printing function
The integrated water quality tester comes with a thermal printer that can directly print measurement data and historical data.
Mass storage
Can store 30000 historical records, with power-off protection design to ensure that the instrument is not damaged
And data records are not lost.
Automatic calibration system
The calibration mode from 1 o'clock to 7 o'clock automatically calculates slope, intercept, and correlation coefficient, with high measurement accuracy.
Dissolve multiple water samples at once
It can digest 12 water samples at once, with a large amount of digestion and faster efficiency.
Product Qualification Certificate
The details of obtaining multiple product qualification certificates are as follows
Instrument information parameters
The product parameters details of HX-E water quality analyzer are as follows
Instrument Name HX-E type water quality tester Display mode 240 * 128 LCD display screen
Curve parameters 100 measurement curve parameters can be set calibration 1-7 point calibration mode automatically corrects curve values
clock Built in real-time clock with monthly cumulative error less than 10 seconds for recording and storage 30000 measurement results with no loss of data due to power outage
print Comes with thermal printer communication model RS232
temperature control 45℃~190℃ Temperature field uniformity ≤ 2 ℃
Dissolve quantity ≤ 12 pieces Dissolving temperature ≤200℃
digestion time 0 minutes to 999 minutes Temperature indication error ≤± 2%
Overall Power Consumption Standby: 4.2W; Job: 524W working power supply AC220V±15%/50Hz
ambient temperature (5-40) ℃ ambient humidity Relative humidity<85% RH (non condensing)
External dimensions 420mm * 310mm * 125mm Weight 6.25kg
Measurable indicators
Can be freely matched according to needs
The measurement method for measuring indicators is based on the standard measurement range (can be diluted in excess range) to determine the measurement error
COD (high range) Rapid catalytic method HJ/T399-2007 5~10000mg/L ≤±5%
COD (low range) Rapid catalytic method HJ/T399-2007 5~150mg/L ≤±5%
CODMn acid digestion spectrophotometric method GB11892-89 0~50mg/L range (segmented) ≤± 8%
Ammonia nitrogen Nessler's colorimetric method HJ535-2009 0.01mg/L~50mg/L ≤± 5%
total phosphorus Ammonium molybdate method GB·11893-89 0.01mg/L~24mg/L ≤±5%
total nitrogen Peroxysulfate oxidation method, recognized by the US EPA, method 0~100mg/L ≤± 5%
nitrate nitrogen Chromium acid transformation method recognized by the US EPA, method 0~100mg/L ≤±5%
Nitrite nitrogen diazotization method GB7493-87 0~6mg/L ≤±5%
Residual chlorine DPD method HJ586-2010 0.01mg/L~10mg/L ≤± 5%
total chlorine DPD method HJ586-2010 0.01mg/L~10mg/L ≤±5%
chlorine dioxide DPD method Adaptation of the "Standard Testing Methods for Water and Wastewater" to 0.01mg/L~5mg/L ≤± 5%
hexavalent chromium Diphenylcarbazide method GB7467-87 0.01mg/L~5mg/L ≤± 5%
chroma spectrophotometry Standard Testing Methods for Water and Wastewater 0~500Hazen ≤±5%
turbidity Platinum cobalt colorimetric method GB·13200-91 0~400NTU ≤±5%
Suspended solids Spectrophotometriclaw Enterprise standard 0~500mg/L ≤± 5%
sulfate Turbidity colorimetric method Adaptation of "Standard Testing Methods for Water and Wastewater" 0~200mg/L ≤±5%
fluoride Fluorine reagent method HJ488-2009 0~12mg/L ≤±5%
barium Enterprise standard for sodium tetraphenylborate turbidity method 0.01mg/L~30mg/L ≤± 5%
aniline Naphthalene ethylenediamine azo photometric method GB1189-89 0.01mg/L~20mg/L ≤± 5%
phosphate Ammonium molybdate spectrophotometric method GB11893-89 0.01mg/L~24mg/L ≤±5%
sulfide methylene blue spectrophotometry GB/T16489-1996 0.005mg/L~12mg/L ≤±5%







ph value electrode method GB6920-1986 0~14PH ≤0.01PH