Chengdu Hengtong Xingye Technology Co., Ltd. specializes in recommending the JD01 tipping bucket rain gauge (all metal type), Chengdu rain gauge, and rain gauge manufacturer
JD01 tipping bucket rain gauge (all metal double stage bucket)
1 JD01 tipping bucket rain gauge (all metal type), Chengdu rain gauge, rain gauge manufacturer overview
This instrument is a multi-layer tipping bucket sensor, and its performance complies with the national standard GB/T11832-2002 "tipping bucket rain gauge", and the China Meteorological Administration's "Guidelines for Meteorological Instruments and Observation Methods" (Sixth Edition) and related requirements.
This instrument adopts two inventions (No.: ZL.5;. 1) A bidirectional flap device and a cascade controlled release funnel for smoothing rainfall intensity have been installed above the measuring hopper, effectively improving the quality of precipitation data observation.
This instrument can be connected to a data collector or computer for various types of meteorological stations, hydrological stations, and rainfall observation stations to accurately measure the start and end time, cumulative precipitation, and precipitation intensity of precipitation.
2 Performance characteristics
Compared with other types of tipping bucket rain sensors, this model of sensor has the following advantages:
2.1After adopting the above two invention technologies, the system error of this instrument can be reduced to a level of ≤± 1%, and its performance is more stable and reliable. The method of on-site calibration of instrument errors is also more convenient;
2.2The machine center bracket of this instrument is a metal casting integrated bracket, which has the advantages of good repeatability and stability in disassembly and assembly;
2.3 The screw for adjusting the capacity of the tipping bucket in this instrument is designed with a "fine thread" for more precise adjustment of the tipping bucket capacity;
2.4The counting bucket of this instrument is equipped with two constant magnets and two corresponding reed switches, making the signal transmission of the instrument more reliable.
3 Main technical parameters of JD01 tipping bucket rain gauge
3.1 Rain bearing diameter: φ20000.60Mm; Sharp edge: 40o~45°
3.2Resolution: 01mm
3.3Rain intensity range: 0.01mm-4mm/min (Allow maximum heavy rain intensity of 8mm/min)
3.4Measurement error: ≤ ±4%(Meets the accuracy requirements of National Standard III)
≤±3%(Meets the accuracy requirements of Level II of the national standard)
≤±2%(Meets the accuracy requirements of National Standard Level I)
≤±1%(accuracySuperior to the national Level I standard)
3.5Message sending method: Two channel reed switch on/off signal output
3.6Working environment: Environmental temperature:- 10℃~50℃
Relative humidity:< 95%(40℃)
3.7size、weight: Size:φ216mm×470mm
Weight:3.8Kg