JW-BK Atmospheric Pressure Physical Adsorption Instrument
The specific surface area and pore size distribution of JW-BK200 series are one of the important parameters to characterize the surface physical prope
Product details

JW-BK200 series

Specific surface area and pore size distribution are one of the important parameters to characterize the surface physical properties and pore structure of micro/nano powder materials. Static volumetric gas adsorption is a common and reliable method. The JW-BK200 series high-performance physical adsorption instrument can accurately and reliably solve the problems of specific surface area and pore size analysis of powder materials. This series of products is divided into three models: A, B, and C according to different testing functions. Among them, the high-end C-type research grade equipment is equipped with ultra-low pressure 1-torr or 0.1torr pressure sensors and 10-8Pa ultra-low vacuum turbo molecular pump in both stations, which can effectively solve the high-efficiency ultra microporous analysis of multi microporous samples such as molecular sieves, catalysts, and activated carbon.

Outline

Product Overview


Testing principle

Under low temperature conditions (such as liquid nitrogen or liquid argon), the pressure of the adsorbate gas is changed in a closed vacuum system. The pressure change before and after the sample adsorbs gas molecules is measured by a high-precision pressure sensor, and the gas adsorption amount is calculated. The isothermal adsorption desorption curve is depicted, and various physical analysis models are applied for specific surface area and porosity analysis.



Product Features

Testing principle

Under low temperature conditions (such as liquid nitrogen or liquid argon), the pressure of the adsorbate gas is changed in a closed vacuum system. The pressure change before and after the sample adsorbs gas molecules is measured by a high-precision pressure sensor, and the gas adsorption amount is calculated. The isothermal adsorption desorption curve is depicted, and various physical analysis models are applied for specific surface area and porosity analysis.

Testing module

Core design, small dead volume space Vd, real-time detection and control of internal temperature Td, ensuring the scientific and accurate determination of adsorption capacity.

Saturated vapor pressure P0

Core design, real-time detection, configuration of independent P0 test pressure sensor 133KPa, P0Point by point testing and real-time calculation of P/P0 for more reliable data. You can also choose to use atmospheric pressure input method to test P0value

Cold Free Space

He automatic calibration, suitable for any powder or particle material

Vacuum degassing

A standardized design that integrates in-situ and ex situ vacuum degassing. During sample analysis, two additional samples can be subjected to ex situ degassing treatment at different temperatures and times; The analysis station can simultaneously perform simultaneous degassing treatment of two samples at different temperatures and times

Micro pore distribution

The HK and SF microporous analysis models are accurately applied, with a pore size deviation of less than 0.02 nm, and have been certified by the China Institute of Metrology

Easy to operate, humanized design

Ethernet data collection, guided operation software, one computer can control multiple instruments simultaneously and remotely;

Strong upgradability

The BK200 series adopts a unified standard container module and supports upgrading from Type A and Type B to research grade Type C; The vacuum system serves the analysis station and the degassing station, and can be upgraded to a second set of vacuum system, which can be independently applied to the degassing station and the analysis station. The second vacuum system can also be equipped with a molecular pump (suitable for C-type); Upgradeable multi-channel intake, * * 8 test gases (including backfill gas), 1 He, facilitating automatic selection of adsorption testing for multiple gases; Supporting the selective adsorption performance analysis of two unique mixed gases at home and abroad, it provides a very meaningful analytical method for the field of gas environment purification.

Pressure sensor

Core component, high-precision capacitive thin film pressure sensor, C-type configuration with 1 torr (optional 0.1 torr) enables gas partial pressure P/P0 in physical adsorption analysis to reach 10-7-10-8(N2/77K)

Liquid nitrogen surface control

Adopting comprehensive control technologies such as 3L large capacity vacuum glass inner Dewar flask, efficient sealing, small inner section, and software correction, the non-uniform temperature field inside the sample tube is kept relatively constant (isothermal) during the testing process

Anti pumping flying

Self controlled adjustable multi-channel parallel vacuum system, with precise "step like" automatic control of vacuum pumping speed to prevent sample flying; At the same time, a built-in anti pumping unit is designed to minimize the possibility of ultrafine powder being pumped away, effectively avoiding instrument contamination

NLDFT

The non local density function theoretical aperture analysis software, developed in deep cooperation with Beijing University of Chemical Technology and Suzhou University, fills the gap and is in line with international standards. It covers various microporous materials such as carbon materials and molecular sieves, and dynamically displays each adsorption equilibrium process on the testing interface. It can clearly understand the adsorption characteristics of the sample, monitor the experimental process, help analyze abnormal phenomena, and also display the internal action process of the instrument through the event bar and indicator lights. It is a unique and valuable humanized design;

The pressure and temperature changes inside the manifold can be visually and clearly observed through the testing interface, which is convenient for instrument maintenance and easy to test the current atmospheric pressure requirements;

The test data is automatically saved as source files, supporting offline and simultaneous analysis of multiple documents. It can be copied, and more than ten physical adsorption analysis models such as BET, Langmuir, BJH, t-plots, etc. are available for selection and use;

Preprocessing includes two types: random independent and same position processing, which can be selected and used as needed. It is a miniature movable heating furnace, ≤ 400 ° C ± 1 ° C, capable of implementing 10 stage program control. Design;



software control

JWGB-BK Software is an intelligent software that implements operation control, data acquisition, calculation analysis, and report generation on the Windows platform. It communicates with the host through a LAN port and can achieve remote control



Typical analysis examples

-The BET repeatability error of the ultra small specific surface area test of iron ore powder is only 0.0015m2/g;

-BET specific surface area, pore size, and pore volume analysis of macroporous materials in white carbon black;




Adopting a unique intelligent judgment and control method for adsorption equilibrium pressure, the pressure of adsorption and desorption processes is optimized in six stages. Under the condition of ensuring sufficient adsorption equilibrium, the testing efficiency is much higher than that of foreign instruments, creating valuable advantages. A complete physical adsorption calculation model is available for flexible selection, including:

-Isothermal adsorption desorption curve;
-BET specific surface area (single point, multi-point);
-Langmuir surface area;
-Surface Area (STSA);
-BJH aperture analysis;
-T-plot analysis;
-DR, DA, MP methods;
-HK aperture analysis;
-SF aperture analysis;
-NLDFT aperture distribution;
-*What is the pore size, average pore size, and total pore volume;
-Adsorption curve, adsorption heat calculation, etc;

-BET specific surface area, pore size, and pore volume analysis of macroporous materials in white carbon black;

-NLDFT pore size distribution analysis of activated carbon materials;



Specification

performance parameter

model JW-BK200A JW-BK200B JW-BK200C
Testing principle Static Capacity Method for Gas Adsorption
Adsorbent gas N2、 Ar、Kr、H2、 O2、 CO2、 CO、NH3、 CH4Waiting for non corrosive gases
Analyze the mouth 2, alternate testing Two, tested simultaneously in parallel 2, alternate testing
Range of specific surface area 0.0005m2/G to an unknown upper limit;
The repeatability (relative standard deviation) of the standard sample is ≤± 1.0%;
0.0005m2/G to an unknown upper limit;
The repeatability (relative standard deviation) of the standard sample is ≤± 1.0%;
0.0005m2/G to an unknown upper limit;
The repeatability (relative standard deviation) of the standard sample is ≤± 1.0%;
Aperture range 0.35nm-500nm;
Accurate analysis of mesopores larger than 2nm;
Median aperture repeatability (standard deviation) ≤ 0.2nm;
0.35nm-500nm;
Accurate analysis of 0.7nm-2nm micropores;
Median aperture repeatability (standard deviation) ≤ 0.02nm;
0.35nm-500nm;
Accurate analysis of 0.35nm-2nm micropores;
Median aperture repeatability (standard deviation) ≤ 0.02nm;
*Small hole volume 0.0001cm3/g
Pressure sensor (analysis station) Two 1000torrs Two 1000torrs
10torr 1 (optional 2)
1 torr (optional 0.1 torr) with 1 option
Two 1000torrs
10torr 2 pieces
1 torr (optional 0.1 torr) 2 pieces
Pressure sensor (P0 station) 133KPa 2 pieces
Relative pressure P/P0 range 10-5-0.998 10-6-0.998 10-8-0.998
Degassing station 2 ectopic vacuum heating and degassing stations;
(The analysis station can perform vacuum heating and simultaneous degassing of 2 samples)
Degassing temperature Room temperature -400 ℃, accuracy 1 ℃
Cold trap station 1 piece
Vacuum pump Double stage rotary vane mechanical vacuum pump, ultimate vacuum 7 * 10-2Pa Double stage rotary vane mechanical vacuum pump, ultimate vacuum 7 * 10-2Pa+two-stage adsorption pump technology (optional turbo molecular pump) German turbo molecular pump (maximum vacuum 10-8Pa)+Front mechanical vacuum pump (ultimate vacuum 7 * 10)-2Pa)
Host specifications Length 870mm x Width 570mm x Height 890mm, Weight Approximately 80 Kg -90 Kg
Environmental temperature requirements Room temperature, it is recommended to equip with air conditioning
Environmental humidity requirements 10%-90%
Power requirements AC 220V ± 20V, 50/60HZ, * * power 300W, current 5A;
Recommended application areas Carbon black, white carbon black, calcium carbonate, titanium dioxide, alumina, zinc oxide, silicon carbide and other ceramic raw materials. Activated carbon materials, molecular sieves, catalysts, active metal oxides, MOF materials, etc.

Accessory