Taizhou Meixu Instrument Equipment Co., Ltd
Home>Products>JYD-1A portable dissolved oxygen meter
JYD-1A portable dissolved oxygen meter
The JYD-1A portable dissolved oxygen meter is designed based on the "Water and Wastewater Monitoring Method" (compiled by the editorial committee of t
Product details

JYD-1APortable dissolved oxygen meterIt is designed based on the "Water and Wastewater Monitoring Methods" (compiled by the editorial committee of the Environmental Protection Bureau's "Water and Wastewater Monitoring and Analysis Methods", third edition).
JYD-1APortable dissolved oxygen meterPowered by batteries, it has a compact appearance and is easy to carry. The digital display directly shows the dissolved oxygen mg/L value of the tested water sample, which can be tested directly in the field. This instrument can be used in aquaculture farms, water treatment plants, sewage treatment, environmental protection monitoring, and research institutes to meet the requirements for measuring dissolved oxygen in water samples.

JYD-1APortable dissolved oxygen meterIt consists of two parts: the host and the oxygen electrode. The oxygen electrode (also known as the oxygen sensitive membrane electrode) consists of two metal electrodes (designed as Ag AgCl, Pt) in contact with a supporting electrolyte (the electrolyte used in this instrument is 0.5mol/L KCl) and a selective thin film (also known as the oxygen membrane).

Oxygen membranes can only pass through oxygen and other gases, and cannot pass through water and soluble substances. The oxygen passing through the oxygen membrane is reduced on the electrode, generating a weak diffusion current, which is proportional to the dissolved oxygen content in the water sample at a certain temperature. Quantitatively measuring this diffusion current can determine the mg/L value of dissolved oxygen in the water sample.

JYD-1APortable dissolved oxygen meterMain technical indicators and instrument working conditions

lMeasurement range: dissolved oxygen (DO): 0-20mg/L Accuracy: ± 0.2mg/L

Temperature (T): 0-40 ℃ Accuracy: ± 1 ℃

2Stability: ± 0.2mg/L · h

3Automatic temperature compensation range: 0-40 ℃, relative humidity<80%

4Response time: less than 30 seconds Oxygen electrode residual current: ≤ 0.005μA

5Dimensions: 140mm × 65mm × 30mm Weight: less than 230g

6Power supply (built-in): 1 6F22 9V battery